24
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
MAINTENANCE
FAN MAINTENANCE
If your fan requires maintenance or replace-
ment it must be performed by an authorised
person. Access to the fan is through the plate
on the rear wall of the firebox.
NOTE: the unit
MUST NOT be operated without the fan
access panel securely in place and cor-
rectly sealed.
IMPORTANT: These fans collect a
lot of dust from within your home.
Ensure you maintain these fan mo-
tors on a regular basis by vacuum-
ing out the fan squirrel cages, around
the motor, and around the grills on
the back of the stove.
TO REMOVE FAN
1)
Unplug or disconnect power source to
stove.
2)
Remove the rear access panel on the back
of the stove. The fan can only be accessed
from the back of the stove.
IMPORTANT
Disconnect power supply
before servicing.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not
cut or remove the grounding
prong from this plug.
3)
Unclip the wires from the fan motor.
4)
Lift fan off of the 2 pins, tip back and pull
through the opening. Disconnect the green
ground wire from the right side of the fan
as soon as you can reach it.
REPLACING FAN
Reverse the above steps (1 - 4). Make sure the
fan wires and the ground wire are reattached.
Hint for pushing fan down onto pins - rub a bit
of dish soap on the grommet so it will slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.
All manuals and user guides at all-guides.com