LATCH  ADJUSTMENT

The door latch may require adjustment as the

door gasket material compresses after a few

fires  and  after  glass  replacement.  Turn  the

handle  on  the  adjustable  catch  to  tighten  or

loosen the latch.

Installing Glass

1)

Install  both  center  and  side  glass  onto

extrusions as per diagram.

2)

Place glass assembly into door frame.

3)

Install retainers by placing 1 drop of glue

where previously glued and put in place.

4)

Install side retainers.

5)

Install door catch plate.

6)

Install the 24 nuts loosely, do not tighten

yet.

7)

Tighten side panels nuts using the follow-

ing  procedure:

a. tighten  top  &  bottom  outside  corner

nuts  (2)

b. tighten inside nuts (3)

c. tighten top & bottom inside corners (2)

PANEL DOOR

1)

Remove the door from the unit and place on

a  soft  surface  to  prevent  scratching.

2)

Pull out the door gasket.

3)

Remove the nuts holding the glass retain-

ers in place.

4)

Remove the glass retainers (sides, top and

bottom) and the door catch plate.

5)

Replace the glass. 

The glass must have

gasketing  around  it.

6)

Reverse  the  previous  steps,  replace  the

retainers and fasten with the nuts but do

not  overtighten,  as  this  can  break  the

glass. Note: the  door catch plate fits on top

of the left side retainer.

7)

Put gasket glue on the retainers, but do not

put glue on the screws. Replace the door

gasket, the two ends butt tight together on

the bottom edge of the door.

8)

Replace door on the stove and check the

seal.

8)

Tighten the 10 nuts on center glass retain-

er.

9)

Repeat step 7 for other side panel.

10)

Replace new gasket by gluing it in place.

11)

Install door onto stove and check the seal.

MAINTENANCE

LOG  REPLACEMENT

The unit should never be used with broken logs.

Turn off the gas valve and allow the unit to cool

before  opening  door  to  carefully  remove  the

logs. The pilot light generates enough heat to

burn someone. If for any reason a log should

need  replacement,  you  must  use  the  proper

replacement  log.  The  position  of  these  logs

must be as shown in the diagram under Log

Installation.

Note: Improper  positioning  of  logs  may

create  carbon  build-up  and  will  al-

ter  the  unit’s  performance  which

is  not  covered  under  warranty.

GLASS  REPLACEMENT

Your  Regency  stove  is  supplied  with  high

temperature,  5  mm  Neoceram  ceramic  glass

that will withstand the highest heat that your unit

will produce. In the event that you break your

glass,  purchase  your  replacement  from  an

authorized Regency dealer only, and follow the

step-by-step  instructions  for  replacement.

Never  operate  your  unit  with  bro-

ken glass.

WARNING:  Do  not  operate  appli-

ance with the glass front removed,

cracked or broken. Replacement of

the  glass  should  be  done  by  a  li-

censed or qualified service person.

MITRED DOOR

Removing Glass:

Note: Wearing  gloves  will  protect  your

hands  while  handling  glass.

1)

Remove the door from the unit and place on

a  soft  surface  to  prevent  scratching.

2)

Pull out the door gasket.

3)

Remove the 24 nuts holding the glass retain-

ers in place. 

Do not remove the nuts under-

neath  the  retainers.

4)

Remove the door catch plate.

5)

Remove  glass  retainers  on  sides  first  (3

each side) then remove two center retain-

ers.

Note: Center  glass  retainers  are  glued

to  center  glass.

6)

Remove  glass  from  extrusions.  When  re-

moving center glass, leave white insulation

in place.

All manuals and user guides at all-guides.com

Содержание FireGenie FG37-LPG

Страница 1: ...e agency or the gas supplier FORYOURSAFETY Donotstoreorusegasolineorotherflamma ble vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGSANDCODEAPPROVALS Thesegasapplianceshavebeentested inaccor...

Страница 2: ...rovide you with all the warmth and charm of a woodstove at the flick of a switch The models FG37 NG and F37 LPG of this series hasbeenapprovedbyWarnockHerseyforbothsafetyandefficiency Asitalsobearsourownmark itpromisestoprovide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourselfwiththeseinstructionsandthemanyfeaturesofyourRegenc...

Страница 3: ...stallation Specifications 5 Before You Start 5 GeneralSafetyInformation 5 Installation Checklist 6 ClearancestoCombustibles 6 Locating Your REGENCY Gas Stove 6 Combustion and Ventilation Air 6 Exterior Flue Terminal Locations 7 FluingInstallationPrecautions 8 Safety Precautions for the Installer 8 Planning Your Fluing Installation 8 FluingArrangements VerticalTerminations 9 Flue Restrictor Positio...

Страница 4: ... Gas Stove We have printed a copy of DATA PLATE the contents here for your review The data plate is located on the inside of the drop down pedestal door NOTE Regency units are constantly being improved Checkthelabelontheunitandifthere is a difference the label on the unit is the correct one AustraliaOnly All manuals and user guides at all guides com ...

Страница 5: ...ruc tions 5 Inspect the flueing system annually for blockage and any signs of deterioration 6 Flueing terminals shall not be recessed into a wall or siding 7 Any safety glass removed for servicing must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Wear gloves and safety glasses for pro tection while ...

Страница 6: ...e is Listed for bedroom installa tions when used with a Listed Millivolt Thermo stat Some areas may have further require ments check local codes before installation This appliance is Listed for Alcove installations maintain minimum Alcove clearances as fol lows minimum ceiling height of 1 7m minimum width of 1 0m and a maximum depth of 0 9m INSTALLATION Use the minimum clearances shown in the diag...

Страница 7: ...et or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below Clearance k in mm Space Heaters All Other Ap...

Страница 8: ...ency Industries Ltd Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire haz ard Do not fill air spaces with insu lation The minimum clearance requirements between the outer wall of the flue pipe and nearby combustible surfaces is 30mm Be sure to check the flue termination clearance require ments from decks windows soffits gas reg ulators air supply inlets ...

Страница 9: ...s below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations Maximum one 90o elbow All vertical and offset to vertical flue installations require Flue Restrictor to be set to 32mm open If the flue is ENCLOSED in a chase min size 229mm x 229mm maintain a 32mm clearance to combustibles All Vertical Flue Terminals must be Simpson Dura Vent Abey A...

Страница 10: ...ocation of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape Kit comes complete with 18 457mm of straight flue 6 5 8 168mm dia black outer pipe and 4 102mm dia inner flue 3 Withthepipeattachedtothestove slidethe stove into its correct...

Страница 11: ...rews at the bottom of the pipe so that the screw heads are hidden on the final instal lation Apply sealant Mill Pac to inner pipe and high temp silicone sealantor Mill Pac toouterpipeon every joint Hint Apply sealant to female end c Before connecting the flue pipe to the flue termination slide the black decorative wall thimble cover over the flue pipe then slide the Wall PenetrationHeatShield Part...

Страница 12: ...ing system by clos ingitsindividualmanualshut off valve during the testing VERTICAL TERMINATION WITH CO LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING ASEPARATESOLIDFUELBURNINGAPPLIANCE This appliance is designed to be attached to two 3 76mm co linear aluminium flex running the fulllengthofthechimney SeetheFluingArrangementschartonpage9forminimumandmaximum flue le...

Страница 13: ... 12 Jumper Location Jumper 8 Remove the NG orifice and replace it with the LPG orifice 9 Install the pilot tube to the pilot assembly 10 Placethepilotassemblyoverthepilotextru sion tube and secure it with 2 screws 11 Adjust the burner areation setting to fully open and install the burner 12 Remove the pedestal back cover by remov ing the 4 Philips screws Pilot Tube 7 Lift the pilot assembly and re...

Страница 14: ...odulator it is necessary that the plastic cap A is returned to its original location 23 At the end of all setting and adjustment operations check electrical insulation and gas leaks 24 Reverse step 20 25 Check operation of fan and flame control 26 Check for proper flame appearance and glow on logs Cable Electric Modulator 22 Adjusting the Outlet Pressure All the adjustments must be carried out in ...

Страница 15: ...d under warranty LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Front Right Log f 02 47 Center Log g 02 48 Middle Ri...

Страница 16: ...ket A 02 65 The bottom right edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 1 3 Close the door The latch plate must be centered around the alignment pin See dia gram 2 If the latch plate interferes with the cor ner of the stove you may want to angle the plate slightly so the door clos es easier 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 ...

Страница 17: ...position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 8mm ID hose 4 Light the pilot and turn the valve to ON position Read manometer 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When fi...

Страница 18: ...ous operation WARNING ElectricalGroundingInstructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be pluggeddirectlyintoaproperlygroundedthree prongreceptacle Donotcutorremovethegroundingprongfromthisplug This heater does not require a 240V A C supply for the gas control to operate A 240V A C power supply is needed for the fan ...

Страница 19: ...e pieces of door glass are properly positioned Never operate the appliance with any of the glass removed or with the door open 5 Verify that all flueing and the cap is unob structed 6 Verify log placement LIGHTING INSTRUCTIONS 1 Plug the power cord into a power outlet 2 Press and release the ON OFF button once to start the unit 3 After approximately 3 seconds the spark ignition system will spark f...

Страница 20: ...e cracking and ticking sounds will be heard throughout the cycling process SUMMARY OF CONTROLS On Off Button If the unit is switched off pressing and releas ing this button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releas ing this button once will switch the unit off Flame Increase If the unit is switched on pressing and releasing t...

Страница 21: ...n under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air LIGHTINGINSTRUCTIONS TO TURN OFF GAS APPLIANCE This appliance must be installed ...

Страница 22: ...oth Never use an abrasive cleaner The gold louvres and optional gold door may be scratched if abrasives are used to clean them The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint not with wall paint Regency uses StoveBright Paint Metallic Black 6309 3 Make a periodic check of burner for proper position and condition Visually check the flame of t...

Страница 23: ...asket by gluing it in place 11 Install door onto stove and check the seal MAINTENANCE LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The positi...

Страница 24: ...IMPORTANT Disconnectpowersupply before servicing WARNING ElectricalGroundingInstructions This appliance is equipped with athreepronged grounding plug foryourprotectionagainstshock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 3 Unclip the wires from the fan motor 4 Lift fan off of the 2 pins tip back an...

Страница 25: ...hain You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint See diagram below 5 Remove the front plate by undoing the 6 screws 6 Disconnect the manual switch cable and reset cables 7 Disconnect the gas pipe line at the valve 8 Remove the pedestal back cover by remov ing the 4 Philips screws 9 Disconnect the 5 pin molex connector...

Страница 26: ...e 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 912 Ignition Module to Valve Cable 910 906 Reset Switch 910 083 Ignition Module 1 910 916 Ignition Module 2 910 514 Jumper N A N A N A N A N A N A N A N A N A N A N A N A N A N A 1 2 2 2 2 3 N A 1 2 2 2 2 2 2 910 912 910 906 910 083 910 916 910 514 Note The Control Box Cable wires for the FG38 come separately...

Страница 27: ...c w J Hook FG37 MAIN ASSEMBLY Part Description Part Description Part Description 25 Flex Pipe 3 ID 26 Clamp for Flex Pipe 27 910 233 Fan Auto On Off Thermodisc 28 Mounting Brckt Thermodisc 29 Air Deflector 30 680 030 RearPanel 31 630 021 Fan Access Panel 32 730 565 Firebox Baffle Restrictor Assembly 33 640 520 False Top Assembly 35 630 011 Air Passage Gasket 38 820 058 Pedestal Base Cover 40 730 0...

Страница 28: ...170 Orifice Gasket 67 PilotHolder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 390 Pilot Orifice 52 NG 75 730 935 Log Set 78 730 550 Burner Assy NG LP Part Description Part Description PARTS LIST 82 630 009 Gasket Burner Tray Air Passage 83 630 008 Gasket Burner Tray Firebox 90 910 386 Thermocouple 91 910 341 Thermopile 69 730 935 Log Set 92 Rear Log 93 Left Top Log 94 Center Log 95 M...

Страница 29: ...Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame Fibre Paper 112 750 015 Door Glass Extrusion 208 940 325 P Wrap Glass Not available as a replacement part All manuals and user guides at all guides com ...

Страница 30: ..._____________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ __...

Страница 31: ... Warranty Lifetime Coveredundertheagreementarethefollowingcomponents Combustionchamber heatexchanger burnertubes logs embers glass thermal breakage and all gold plating againstdefectivemanufacture Theabovewillbecoveredforpartsandlabourforthefirstfive years and parts only thereafter Electrical components such as fans switches wiring thermodiscs remote control thermopiles thermocouples and gas valve...

Страница 32: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved All manuals and user guides at all guides com ...

Отзывы: