FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
19
OPERATING INSTRUCTIONS
FIRST FIRE
The
FIRST FIRE
in your heater is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fireplace for at least four (4) hours
the first time you use it with the fan on.
When first operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
NOTE:
The main burner will always start on
"HIGH" and resume it's last setting after
20 seconds of operation.
NOTE:
When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation is
normal and will disappear in a few
minutes as the glass heats up.
DO NOT ATTEMPT TO CLEAN THE GLASS
WHILE IT IS STILL
HOT
!
DO NOT BURN THE APPLIANCE WITH-
OUT THE GLASS FRONT IN PLACE.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed
through the following check list.
1)
Read and understand these Instructions
before operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5)
Verify that all flueing and the cap is unob-
structed.
6)
Verify log placement.
LIGHTING
INSTRUCTIONS
1)
Plug the power cord into a power outlet.
2)
Press and release the ON/OFF button once
to start the unit.
3)
After approximately 3 seconds the spark
ignition system will spark for 40 seconds to
light the main burner.
4)
If the main burner does not light, reset the
unit.
RESETTING
THE UNIT
1)
Open the pedestal door on the unit.
2)
Press the reset button for approximately 3
seconds and release. The reset button is
located on the unit's control panel.
3)
Wait for approximately 3 seconds and the
pilot sparks can be heard and seen. It would
take 2 to 3 seconds for the flame to be lit.
SHUTDOWN
INSTRUCTIONS
1)
Press the ON/OFF button once.
2)
Turn off all electric power to the appliance
if service is to be performed.
FAN OPERATION
Set the fan speed on the control panel located
in behind the pedestal door to adjust fan to the
desired speed.
ADJUSTING FLAME
HEIGHT
There are six flame settings that can be adjust-
ed by pressing and releasing the plus (+) and
minus (-) FLAME button.
The FLAME setting button is located on the
control panel in behind the pedestal door.
Pressing and releasing the plus (+) FAN button
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.
Pressing and releasing the minus (-) FAN button
will be the reverse of the above.
Control Panel
All manuals and user guides at all-guides.com