E33-10 FPI Direct Vent Gas Insert
|
9
|
9
installation
MINIMUM FIREPLACE
OPENING (LOW PROFILE
FACEPLATE AND SPACER)
The minimum fireplace opening for the Regency gas
fireplace insert is shown in the following diagrams:
MINIMUM FIREPLACE
OPENING
The minimum fireplace opening for the Regency
gas fireplace insert when using the supplied spacer
is shown in the following diagrams:
18"
(457mm)
35-1/4" (895mm)
7-1/8”
(200mm)
Low profile
9-1/4"
(235mm)
25-1/2" (648mm)
18" (457mm)
GAS INSERT
AERATION SYSTEM
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue flame or close for a yellower
flame. The burner aeration is factory set but may
need adjusting due to either the local gas supply
or altitude.
Minimum Air Shutter Opening:
5/16"
Natural Gas
7/16"
Propane
CAUTION: Carbon will be produced if air
shutter is closed too much.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
Note: Aeration Adjustment should only be
performed by an authorized Regency
Installer at the time of installation.