18
|
E33-10 FPI Direct Vent Gas Insert
|
18
installation
1
09.23.14
919-454
E33
2.
Attach the faceplate backing and spacer if installed to the insert
body using 4 screws in as shown in Diagrams 2 and 3.
1.
A spacer is supplied and may be installed if required to extend the
depth of the faceplate by 1-3/4". Install the spacer onto the back
side of the faceplate backing with 8 screws in locations shown
below (3 on each side to secure spacer to faceplate backing and
2 to secure the top piece - Spacer only).
Diagram 2
Diagram 3
Diagram 4
Diagram 5
Diagram 6
Diagram 7
Low profi le faceplate installation
2.
Connect the male end black and red fan switch wires (in the
black casing) to the wire connectors from the fan speed control.
5. Secure the wires to the back of the inner faceplate with a wire clip.
6. Install lower trim to unit with 2 screws on each side as shown in
Diagram 7.
NOTE: Diagram shown without faceplate backing installed to better
illustrate location of holes.
3. Tuck the wires into the clip to keep them away from the insert using
the clip provided. Attach the clip to the rear of the faceplate to en-
sure that the wires do not touch the side of the unit. The power cord
should be run behind the inner faceplate panel.
4. Install the fan speed control box to the left hand bottom leg of the
inner faceplate. Controls located on the left side. One screw at top
(as shown) and one at the bottom.
Diagram 1
LOW PROFILE FACEPLATE INSTALLATION