City Series ACB40E
installation
Horizontal Terminations
Rigid Pipe 102mm x 175mm
The minimum components required for a basic horizontal
termination are:
1 Horizontal Termination Cap
1 Rigid Pipe Adaptor (510-994)
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl siding standoff,
to create a level surface to mount the flue terminal. The Terminal
must not be recessed into siding. Measure the wall thickness
including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl
siding), measure to outside surface of wall without siding and
add 51mm.
When using Rigid Flue other than
Simpson Dura-vent, 3 screws must be
used to secure rigid pipe to adaptor.
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Adj.Pipe Length
Horizontal
Termination Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
Rigid Pipe Adapter
o
90 Elbow
Pipe Length
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with DuraVent Direct-Vent, Selkirk Direct-
Temp, Ameri Vent Direct Venting, ICC Excel
Direct, Olympia Chimney and Security Secure
Flue systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable and
does not affect the Intertek/ WHI listing of
components.
WARNING:
Do not combine flueing components from
different flueing systems.
Use of the AstroCap
TM
and FPI Riser is accept-
able with all systems.
The FPI AstroCap
TM
and FPI Riser Flue terminal are certified for installations using FPI flueing systems as well as Simpson Dura-vent
®
Direct Flue, American
Metal Products Ameri Flue Direct Flue, Security Secure Flue
®
, ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap
TM
is a proprietary trade-
mark of FPI Fireplace Products International Ltd. Dura-vent® and Direct Flue are registered and/or proprietary trademarks of Simpson Dura-vent Co. Inc.
Flat Wall Installation
Wall Thickness
(mm)
Vent Length Required
(mm)
102mm-140mm
152mm
178mm-216mm
229mm
254mm-292mm
305mm
229mm-368mm
279mm-371mm Adj. Pipe
381mm-597mm
432mm-610mm Adj. Pipe