4
|
City Series ACB40E
safety decal
Part #: 920-215 - Side
A
Colours: Black on white, except for parts indicated as being Red.
Punch out .25" hole top right corner where indicated.
Size:
100%
W
- 6.198" x L- 9.18"
Feb. 18/20: Created decal
March 2/20:
Updated serial and lighting plate decals.
Material:
Printable white polyester 7mm
Start serial sequence @ 000001
NOTE: This is a double sided decal
Part #: 920-215 - Side B
Colours: Black on white, except for parts indicated as being Red.
Punch out .25" hole top right corner where indicated.
Size:
100%
w- 6.52"
h- 1
1.13"
Feb. 18/20: Created decal
Part #: 920-111d
Colour: Black on Grey
Size: 100% 7" W x 2.7" H
June10/19: Created decal
June 13/19: Removed -11 as per Daniela
Feb. 12/20: Updated gas consumption low value and injector size.
Feb. 19/20: Added label “Primarily a decorative and not a heating appliance”
Mar. 2/20: Changed some consumption and pressure values.
Serial
Number
Regency Gas Fireplace
527
Distributed by:
Western Australia:
Air Group Australia
28 Division St
Welshpool, WA 6106
Eastern Australia
Fireplace Products
Australia Pty. Ltd.
1 Conquest Way
Hallam, VIC 3803
New Zealand
Aber Holdings
17 Main Street Place
Te Rapa, HA 3200
To be installed by an authorised person in
accordance with installation instructions
provided with the appliance.
Electrical: 240V 50/60 Hz
920-111d
Gas Type
NG Propane ULPG
Model
ACV40ENG ACV40ELP
ACV40EULPG
Gas Consumption High
30 MJ/h 30 MJ/h 24 MJ/h
Manifold Pressure High
0.96 kPa 2.60 kPa 2.60 kPa
0.30 kPa 0.70 kPa 0.63 kPa
Injector Size
2.40 mm 1 x #53 1 x #54
Approval No. GMK10594
AS/NZS 5263.0 & AS/NZS 5263.1.8
Gas Consumption Low
17.1 MJ/h 16.0 MJ/h 11.7 MJ/h
Manifold Pressure Low
ACB40ENG ACB40ELP
ACB40EULPG
Supply Pressure (Min.)
1.13 kPa 2.75 kPa 2.75 kPa
1.51 mm 1.39 mm
PRIMARILY A DECORATIVE AND NOT A
HEATING APPLIANCE
920-214
Part #: 920-214
Colours: Black on Grey
, except for parts indicated as being Red.
Punch out .25" hole top right corner where indicated.
Size:
100%
w- 6.52"
h- 1
1.13"
Feb 18/20: Created decal
Mar 2/20:
Added: "
SUIT
ABLE ONL
Y
FOR INDOOR INST
ALLA
TION", removed French.
DO NOT REMOVE THIS INSTRUCTION PLA
TE
SUIT
ABLE ONL
Y
FOR INDOOR INST
ALLA
TION
This appliance must be installed in accordance with local codes, if any
. If none, follow the current
AS/INZS 5601.
CAUTION: Hot while
in operation.
Do not
touch.
Severe Burns may result. Due to high
surface
temperatures
keep
children,
clothing
and
furniture,
gasoline
and
other
liquids
having
flammable
vapors away
. Keep burner and control
compartment clean. See installation
and operating
instructions accompanying
appliance.
LIGHTING INSTRUCTIONS
FOR
YOUR SAFETY
READ BEFORE LIGHTING
W
ARNING: If you do not follow these instructions exactly
, a fire or explosion may result causing property damage,
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the owner
’s information manual provided with this appliance. For assistance
or additional information consult a qualified installer
, service agency
, or gas supplier
.
A)
BEFORE
LIGHTING
smell
all
around
the
appliance
area
for
gas.
Be
sure
to
smell
next
to
the
floor
because
some
gas
is
heavier than air and will settle on the floor
.
WHA
T T
O DO IF
YOU SMELL
GAS
-
Do not try to light any appliance
-
Do not touch any electric switch, do not use any phone in your building
-
Immediately call your gas supplier from a neighbors phone. Follow the gas supplier
’s instructions.
-
If you cannot reach your gas supplier
, call the fire department.
B)
Do
not
use
this
appliance
if
any
part
has
been
under
water
. Immediately
call
a
qualified
service
technician
to
inspect
the
appliance and to replace any part of the control system and any gas control which has been under water
.
This
appliance
needs
fresh air
for
safe operation
and
must
be
installed
so
there are provisions
for
adequate
combustion
and ventilation air
.
ST
OP! Read the safety information above on this label.
1) Ensure the Main switch is in the ON position and/or the wall mounted battery holder (if equipped) is in the <REMOTE> positio
n.
2) Press and release the ON/OFF button on the remote handheld transmitter
.
An audible beep should be heard from the receiver
. If not
using the remote, the unit can also be turned on by sliding the battery holder switch to the <ON> position (if equipped).
3)
After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner
.
4) The unit will turn on.
Note: The first attempt to ignition will last approximately 60 s
econds. If there is no flame ignition (rectification) the board w
ill stop spark
-
ing for approximately 35 seconds.
After this wait time, the board will start a second try for ignition by sparking for approximately 60
seconds. If there is still no positive ignition after the second attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):
a)
W
ait 5 minutes - turn the system off by pressing the ON/OFF butt
on on the remote.
b)
After approximately 2 seconds, press the ON/OFF button again.
c) Unit will repeat step 2.
T
O TURN OFF GAS
APPLIANCE
1.
Press the ON/OFF button once.
2.
Turn off all electric power to the unit if service is to be perfo
rmed.
920-215
920-215
This is a copy of the label that accompanies Direct Flue Gas
Fireplace. We have printed a copy of the contents here for your
review. The safety label is located on the front inside base of
the unit, visible when the outer front panel is removed.
NOTE: Regency
®
units are constantly being improved. Check
the label on the unit and if there is a difference, the label on
the unit is the correct one.
Copy of Data Badge
Part #: 908-602c
Colour: Black on White, expect what is indicated in yellow.
Size: printed at 100%
July 18/17: Rev. C - Changed wording on Line 3 as per AGA -
removed Lines 4, 6 and 7 - updated caution
symbol size and font size to 10pt
May 7/14: Changed wording on Line 3 as per AGA
Dec 12/12: Removed redundant ‘do not’ from the last line
Mar. 3/09: Rev. A - added information
Nov. 6/06: no changes to artwork.
DO NOT
OPERATE THIS APPLIANCE BEFORE READING THE
INSTRUCTIONS BOOKLET.
DO NOT
PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE
DO NOT
STORE CHEMICALS OR FLAMMABLE MATERIALS
NEAR THIS APPLIANCE.
DO NOT
OPERATE WITH PANELS, COVERS OR GUARDS
REMOVED FROM THIS APPLIANCE.
908-602c