background image

City Series

®

 

Zero Clearance Direct Flue Gas Fireplace

Owners & 

Installation Manual

STYLE

 

     MODEL 

    

Three sided 

ACB40ENG / ACB40ELP / ACB40EULPG

www.regency-fire.com.au

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other

appliance.

- WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

•  Do not touch any electrical switch: do not use any phone in your building.

Leave the building immediately.

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's

instructions.

• If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     Warning
Fire or explosion Hazard

failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

920-121

03.

12

.20

Installer: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

LISTINGS AND CODE APPROVALS

These  gas  appliances  have  been 
tested  in  accordance  with  AS/NZS 
5263.0  &  AS/NZS  5263.1.8:2016 
and have been certified by IAPMO for 
installation and operation as described 
in  these  Installation  and  Operating 
Instructions.
Must be installed as per AS/NZS5601.

Your unit should be serviced 
annually by an authorised service 
person.

PRIMARILY A DECORATIVE AND NOT A 
HEATING APPLIANCE.

DO NOT MODIFY THIS APPLIANCE.

Содержание City ACB40ELP

Страница 1: ...ervice must be performed by a qualified installer service agency or the gas supplier Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property damage 920 121 03 12 20 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference LISTINGS...

Страница 2: ...with all the warmth and charm of a wood fireplace at the flick of a switch The ACB40E City Series has been approved by IAPMO for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Firepla...

Страница 3: ...Lighting Procedure 8 Shutdown Procedure 8 Copy of the Lighting Plate Instructions 9 Proflame II Remote Control Operating Instructions 10 Outer Safety Glass Panel Installation Removal 14 Inner Glass Panel Installation Removal 16 Maintenance Instructions 18 General Flue Maintenance 18 Log Replacement 18 Glass Gasket 18 Glass 18 Glass Replacement 18 General Safety Information 19 Installation Checklis...

Страница 4: ...itional information consult A BEFORE LIGHTING smell all aro heavier than air and will settle on WHAT TO DO IF YOU SMELL GAS Do not try to light any applianc Do not touch any electric switc Immediately call your gas supp If you cannot reach your gas s B Do not use this appliance if any p appliance and to replace any part This appliance needs fresh air for s and ventilation air ST 1 Ensure the Main ...

Страница 5: ...City Series ACB40E 5 dimensions Dimensions Note Height Dimension may vary depending on the height of the leveling legs Note These units are non load bearing ...

Страница 6: ...CES Important Message SAVE THESE INSTRUCTIONS City Line Direct Flue Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliancewit...

Страница 7: ... must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace 9 Wear gloves and safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have t...

Страница 8: ...r switch to the ON position if equipped Note The first try for ignition will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will ne...

Страница 9: ...l your gas supplier from a neighbors phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department B Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water This appliance needs fresh a...

Страница 10: ...r Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 433 92 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of re...

Страница 11: ...step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermost...

Страница 12: ...he fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activ...

Страница 13: ...is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility t...

Страница 14: ...ANDLING We recommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty We recommend handling the glass with supplied va...

Страница 15: ...ent to better illustrate the install this area is not visible when installing glass 4 With front panel installed proceed to install the side panel s Identify the left and right side panels before installing Facing the front of the unit the right panel will show an arrow pointing to the front of the unit as shown in the diagram below Note After the side panel has been adjusted so it is installed at...

Страница 16: ...n Push side glass panel firmly to back wall until springs are compressed then close clamps Important Prior to installing the inner glass ensure that there is no media present in the bottom channel as this can cause damage to the glass Remove any media from bottom channel prior to installing the glass WARNING GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufac turer L...

Страница 17: ...h the front panel in position secure in place by closing the 3 lower clamps and 4 upper clamps Open clamps to release pressure on the springs Press glass vacuum clamps in open position firmly onto surface of glass Bring handles together to close Open Closed 7 Return to the side panel s and release the upper and lower clamps The springs will release and push the glass side panel forward slightly th...

Страница 18: ...GlassInstallation section REPLACEMENT GLASS ACB40E Outer Safety Glass Front Tempered Part 940 438 P Outer Safety Glass Right Side Tempered Part 940 439 P Outer Safety Glass Left Side Tempered Part 940 440 P Inner Glass Front Ceramic Part 940 436 P Inner Glass Side Ceramic Part 940 437 P Maintenance Instructions 1 Always turn off the gas valve before cleaning Forrelighting refertolightinginstructio...

Страница 19: ...al codes with the current Canadian or National Gas Codes CAN1 B149orANSI Z223 1Installation Codes 2 See general construction and assembly instructions The appliance and flue should be enclosed 3 This appliance must be connected to the specifiedflueandterminationcaptotheoutside of the building envelope Never flue to another room or inside a building Make sure that the flue is fitted as per Flueing ...

Страница 20: ...urements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For flue terminations refer to Exterior Flue Termination Locations section Unit Assembly Prior to Installation Before you start The ACB40E has only 2 standoffs at the back that need assembly before installation WARNING Ri...

Страница 21: ...ax 76mm From top of enclosure H Convection Air outlet 306sq cm min Top front or side of enclosure I Enclosure Depth min 483mm Minimum inside dimensions J Opening Height 383mm Bottom Top of Fireplace Opening K To Ceiling min All 3 sides 38mm To Top of Ceiling L Chase Enclosure min 1600mm From base of unit floor M Clearance to sprinkler head Min 914mm Perpendicular from chase grill Hearth 0mm No hea...

Страница 22: ...o ceiling with top opening Low framing with flues in front sides or top Full framing with low flues in front or sides Full framing with flues in front or sides K C I A1 A D L J H B L I C D A1 A J G G H H H B I C G A A1 G D J L H H B I B A D C J G G L H H ...

Страница 23: ...top of front facing are shown in the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 305mm MANTEL LEG 216mm 254 0 229mm 383mm 254 508 Top of Fireplace Opening 305mm 13mm Plasterboard timber timber panel etc To Bottomof Fireplace Opening 130mm 127 ...

Страница 24: ... Framing Depth 483mm D Minimum Height to Combustibles 1600mm G Flue Centerline Height 1429mm I Gas Connection Opening Height 51mm J Gas Connection Height 106mm K Gas Connection Inset 330mm L Gas Connection Opening Width 89mm Note A combined minimum of 774 square centimetres of open area is required for the convection air outlet to cool the enclosure Ensure clearances for Convection Air Outlets are...

Страница 25: ...ing strips are not required and can be recycled when using the framing kit 1 Start with the unit away from the wall install Part A x2 to the back of the unit with 2 screws on each side Note the correct orientation of part A as there is a left and a right See diagram below Part A Install Orientation to Unit Screw Locations Note Extra screws are provided to assemble this kit Tools hardware needed ar...

Страница 26: ...unit is level from front to back and side to side and Parts A B are square Secure the unit with framing to the wall studs with 76 mm wood screws Use 8 screws and secure to 4 studs minimum Install venting before proceeding further with framing kit construction Refer to manual for venting instructions 5 Install one screw lower screw position into B1 and B2 Hang the pre as sembled RIGHT sidewall off ...

Страница 27: ...shown below Attach Part O x2 and Q x2 to Part B2 B2 B3 must be secured to framing studs with a minimum of 8 screws Install screw to set height for panel install 11 Attach Part B3 to extended LEFT and RIGHT sides with two screws on each side from the front 12 Secure B3 to the wall studs with 76mm wood screws Use 8 screws and secure to 4 studs minimum Attach Part O x2 to Part B3 Part B3 Part B3 Part...

Страница 28: ... 4 bottom 17 Position Part M x2 to nest in behind Part I x2 and secure to Part I with 3 screws each and Part L with 4 screws each See 2 drawings shown below noting orientation of Part M Attach Part I x2 to Part S H Attach Part M x2 to Part L Part I screw holes located on the side Attach Part L x2 to LEFT and RIGHT sides 14 Secure Part Q to top Part S with 1 screw each Part L Part M Part H Part Q P...

Страница 29: ...cover install Extended framing kit bottom cover install Bottom cover Top Part O 18 Swing Top Part O out from B3 20 Attach corner brace Part P to the LEFT side and Part H with 4 screws from the top 21 Attach the opposite corner brace Part P to the RIGHT side and Part H with 4 screws from the top Swing Parts O out and attach Attach Part P Left to the LEFT SIDE H1 Attach Part P Right to the RIGHT SID...

Страница 30: ...nly Front view Part ID extended shown Back view Part ID extended shown Extended Kit Overall Dimensions Width 1537 mm Depth 475 mm Height min 2032 mm max 3048 mm Compact Kit Overall Dimensions Width 1537 mm Depth 475 mm Height min 2032 mm max 3048 mm Min Max Height measured from base of appli ance finished floor ...

Страница 31: ...mm Stud Stud Stud Stud 1016mm Chase Vent 1016mm Chase Vent C40 Chase Vent Framing Clearances Opening for vent Min 1073mm Framed opening must be between 102mm and 114mm and at least 1073mm wide to accommodate the chase vent The top chase vent opening must be 76mm or less from the top of the case enclosure 102 114mm ...

Страница 32: ...s ACB40E installation Plasterboard HeaderStud C40 Chase Vent Finish Detail Finish edges of plasterboard with trim or corner bead Edge finish must not decrease opening area below 130in2 3 25 x40 839cm2 83mm x 1016mm ...

Страница 33: ...rances Page Screw Chase vent to Framing Use at least 3 sets of screws to keep the vent flat against framing Frame wall with finishing material If necessary mark where the chase vent is located before fixing plasterboard in place Cut hole in finishing material around inside of chase vent Finish edges around opening Plasterboard ...

Страница 34: ...own below Warning DO NOT cover or place objects in front of the air outlet s Regency Chase Vent Dimensions 64mm x 1219mm 774cm2 Custom chase vent Example dimensions Reveal at the chase top Example dimensions 81mm x 1016mm 839cm2 851mm x 1524mm 774cm2 Note The enclosure opening cannot be any lower than 0 76mm from the top of the enclosure for all installations Minimum height of enclo sure from base...

Страница 35: ...To install the front grill frame an opening of 111mm H x 994mm W The finished facing material should be attached and be the same size as the framed opening to eliminate gaps Install the grill and secure in place with one screw on either side installed from the front Note Front grill not used in conjunction with the steel stud framing kit 111mm 994mm Maximum 76mm from top of enclosure Secure with sc...

Страница 36: ...peat steps to install the second grill to the other side of the chase Note Side grills can be used in conjunction with the steel stud framing kit see instructions below Secure with screws through louvers to the sides Secure with screws through louvers to the sides tooltip tooltip 1 Install the side vent framing onto the framing kit by affixing to Parts K E If the framing kit has already been assem...

Страница 37: ...s line or damage valve or electrical components Note It is acceptable to use a high temperature silicone sealant to adhere plasterboard to lower access cover panel The appliance is designed to be used with 13mm wall sheathing materials such as plasterboard plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing ...

Страница 38: ...angerous operating conditions 6 This appliance comes with a 13mm lip at top sides and bottom to hide the endsoftheplasterboard The13mmsideandbottom frontandbottomside lips supplied with the appliance can alternatively be removed and replaced with J Style Trim or Metal Corner Bead purchased at your local hardware store to cover cut exposed edges of the combustible facing material or any other finis...

Страница 39: ...City Series ACB40E 39 installation TV Recessed into Wall Typical Installs Maximum TV Recess TV Flush with Hearth ACB40E shown ACB40E shown ...

Страница 40: ...40 City Series ACB40E installation Exterior Flue Termination Locations FIGURE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS NZ 5601 ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCE ...

Страница 41: ...s over 250MJ h input 1500 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1500 1000 n Vertically below an openable window non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation Space heaters up to 50MJ h input 150 150 Other appliances up to 50 MJ h input 500 500 Applianc...

Страница 42: ...e 6 pin connector to the back of the Battery Holder 4 Install the Battery Holder in the Low Voltage Junction box 5 Install batteries only if 240 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the...

Страница 43: ...1 Remove the safety glass and firebox glass see instructions in this manual 2 Remove the screws that hold the flue restrictor plate in place see Diagram 1 3 Adjust the flue restrictor plate to the required flue restrictor position as per the diagrams shown 4 Once the flue restrictor plate is in the required position secure with screws Flue Restrictor Position Flue Restrictor Positions Flue restric...

Страница 44: ... Regency Direct Vent System Flex is only approved for horizontal terminations 5 Flex system can only be used up to a maximum continu ous vent length of up to 3m If longer runs are required rigid pipe must be used Flueing Arrangements Horizontal Terminations Flex Vent 102mm x 173mm These flueing systems in combination with the ACV40E Direct Vent Gas Fireplace have been tested and listed as a direct...

Страница 45: ... using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Flueing Systems Maintain clearances to combustibles as listed in Clearances section Horizontal flue must be supported every 0 9m Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the termination is lower tha...

Страница 46: ...e Adapter o 90 Elbow Pipe Length This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent Selkirk Direct Temp Ameri Vent Direct Venting ICC Excel Direct Olympia Chimney and Security Secure Flue systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNING Do...

Страница 47: ...can only be used up to 3m otherwise rigid flueing must be used Horizontal Flueing with Two 2 90o Elbows Horizontal Flueing with Three 3 90o Elbows One 90o elbow Two 45o elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 9 1m with minimum of 1 8m feet total vertical and maximum 2 4m total horizontal Please note minimum 0 3mbetween90o elbows is required...

Страница 48: ...ver 10 12 to 11 12 0 99 over 11 12 to 12 12 1 22 over 12 12 to 14 12 1 52 over 14 12 to 16 12 1 83 over 16 12 to 18 12 2 13 over 18 12 to 20 12 2 29 over 20 12 to 21 12 2 44 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp Am...

Страница 49: ...bow Vent must be supported at offsets Minimum distance between elbows is 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 0 9m Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position se...

Страница 50: ... at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe flue systems Vertical Flueing with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 9 1m with min of 3m total vertical and max 2 4m total horizontal Please note min 0 3m between 90o elbows is required ...

Страница 51: ...llar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved flueing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection...

Страница 52: ... there are markings on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fire place You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90o Th...

Страница 53: ...mance issues not covered under warranty 5 Cut an opening in the roof centered on the small drilled hole placed in the roof in Step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles of 38mm Sliptheflashingundertheshingles shinglesshould overlap half the flashing as per Diagram 3 6 Continue to assemble pipe lengths Note If an offset is necessary i...

Страница 54: ...f an offset is necessary in the attic or floor joists it is important to support the vent pipe every 0 9m to avoid excessive stress and sagging of the vent pipe Wall straps are provided 3 in total for this purpose All round plumbers strapping may also be used if further supports are required 10 Attach the rigid pipe section to the adaptor by using Mill Pac on the inner outer pipe Use 3 screws to s...

Страница 55: ... 2 29 over 20 12 to 21 12 2 44 Diagram 3 Diagram 3a Diagram 3b 13 Slide the finished length up towards the flashing ensuring the length of pipe is a minimum of 0 6m measured from the top of the roof Level the chimney and secure using the roof support provided with kit to bottom side of the roof as shown using a minimum of 2 screws per side see Diagram 3b See Diagram 4 for roof pitch and height req...

Страница 56: ...nsion Kit Part 946 756 Ceiling Firestop Firestop Spacer Part 946 757 920 119 06 06 19 60 Ceiling firestop 60 Ceiling firestop Diagram 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falli...

Страница 57: ...lot Ignitor Pilot Adjustment Periodicallycheckthepilotflames Correctflame pattern has two strong blue flames 1 flowing around the flame sensor and 1 flowing across the burner it does not have to be touching the burner 885 S I T Valve Description 1 6 Stage flame adjustment 2 Pilot adjustment 3 Outlet Pressure Tap 4 Inlet Pressure Tap 5 Pilot Outlet 6 Main Gas Outlet 7 Main Gas Inlet 1 2 3 4 6 5 7 H...

Страница 58: ...he wires do not touch any hot surfaces and are away from sharp edges CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation No electrical power supply is required for the gas control to operate 240 Volt AC power is needed for the lights Electrical power must be brought to the appliance by a licensed electrician Do not cut the...

Страница 59: ...e location of the fireplace and the warm air duct runs see diagram 1 as a guide for possible duct runs and locations Diagram 1 Guide for possible air duct runs and locations Keep duct length and number of bends to a miniumum Maximum duct length is 9 0m The Extension Kit contains a maximum of up to 4 5m Please purchase the Fan Duct Extension Kit to increase the 9 0m MINIMUM FRAMING CLEARANCES Wall ...

Страница 60: ...using Attach the round to oval adapter to the fan housing and the air duct to the adapter 45mm Round to Oval Adapter Fan Housing Secure with 3 Screws and Aluminum Duct Tape at Unit Air Duct 7 Screw the Register Adapter Frame and the Air Register to the Fan Housing See diagram 4 Diagram 4 4 Install the On Off switch in a convenient location This switch controls the fan operation NOTE Variable speed...

Страница 61: ...length WIRING DIAGRAM Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges AlternateSwitches Mayusethefollowing Checkwithlocalauthoritiesandelectrician CLIPSAL 203 2E45 OUD Dimmer CLIPSAL 2031 VF3CSF 3 Speed CAUTION Labelallwirespriortodis connection when servicing controls Wiringerrorscancauseimproperand dangerous operation Wire Nut Wire Nut Wire Nut ON OFF Wi...

Страница 62: ...losed position Push side glass panel firmly to back wall until springs are compressed then close clamps Important Prior to installing the inner glass ensure that there is no media present in the bottom channel as this can cause damage to the glass Remove any media from bottom channel prior to installing the glass WARNING GLASS HANDLING We recommend using the glass vacuum holders supplied by the ma...

Страница 63: ...nel in position secure in place by closing the 3 lower clamps and 4 upper clamps Open clamps to release pressure on the springs Press glass vacuum clamps in open position firmly onto surface of glass Bring handles together to close Open Closed 7 For 3 sided and corner units only Return to the side panel s and release the upper and lower clamps The springs will release and push the glass side panel...

Страница 64: ...ommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be covered under warranty We recommend handling the glass with supplied vacuum clamps Wh...

Страница 65: ...ate the install this area is not visible when installing glass 4 For 3 sided and corner units only With front panel installed proceed to install the side panel s Identify the left and right side panels before installing Facing the front of the unit the right panel will show an arrow pointing to the front of the unit as shown in the diagram below Note After the side panel has been adjusted so it is...

Страница 66: ... of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit includes 1 911 191 Stepper Motor LP for 885 SIT 1 904 947 Propane Orifice 53 1 910 037 Pil...

Страница 67: ...ot orifice 14 Unscrew the pilot orifice with the allen key then replace with the LPG pilot orifice and the pilot cap provided in the kit Installer Notice These instructions must be left with the appliance Pilot retainer clip 12 Remove burner orifice with a 9 5mm spanner Use another wrench to hold on to the elbow behind the orifice Discard orifice Reinstall new burner orifice LP stamped 53 or 54 UL...

Страница 68: ...ront base panel to secure the logo The logo should be about 76 mm from the right hand corner of the outer base Install outer front base panel 2 Install side panel the side panel is secured in place by existing magnets in the unit The CB40E can be equipped with optional steel inner panels CB40E 3 outer panels and 2 inner panels Turn off unit and allow to cool to room temperature Remove the safety g...

Страница 69: ... inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration Black Enamel panels will discolor a little during normal operation This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to r...

Страница 70: ...re required glass crystals beads are used as a base DO NOT overstack Ceramic Spa Stones or Volcanic Stones on burner or in the pilot area Media must be installed on and around burner only in amounts noted below 19mm Crushed black glass Black Fireglass Natural Ivory Stones Fireglass Starfire Fireglass Iceburg chips ACB40E Approved Media Where Used Quantity Fireglass starfire copper or black On burn...

Страница 71: ...oltoroomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Black Fireglass 680g and glowing wool on the burner as shown below Log Guides location of log guides 2 rear 1 front 5 Clip on the log guides position the rear guides by centering over the seco...

Страница 72: ... the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow is open shown with 19mm crushed black glass 11 Place Log 4 identify the pin locator and match with the left side pin on Log 1 Rest the other end of Log 4 on the indent in Log 2 as shown below 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the other end of ...

Страница 73: ...ightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible th...

Страница 74: ...sInstallation section REPLACEMENT GLASS ACB40E Outer Safety Glass Front Tempered Part 940 438 P Outer Safety Glass Right Side Tempered Part 940 439 P Outer Safety Glass Left Side Tempered Part 940 440 P Inner Glass Front Ceramic Part 940 436 P Inner Glass Side Ceramic Part 940 437 P Maintenance Instructions 1 Always turn off the gas valve before cleaning Forrelighting refertolightinginstructions K...

Страница 75: ...in the upper inside front of the firebox and remove 4 Loosen 2 screws on each side of individual inner light cover and remove 5 Remove glass cover by using a flat head screwdriver to pry the tab securing the glass assembly in place 6 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part Ov...

Страница 76: ... instructions in this manual 4 Remove all media and logs if installed set aside 5 Remove inner base panel 7 Remove 16 screws in locations shown below 8 Lift valve tray out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray 9 Reverse steps 6 1 to complete Inner base panel Remove 16 screws securing valve tray ACB40E shown 6 Loosen 4...

Страница 77: ... S 910 037 Pilot Orifice SIT LP 30 977 167 N S 911 037 Flame Sensor 0 915 905 N S 911 038 Flame Electrode 0 915 020 N S 910 432 Novasit Pilot Tubing With Nuts N S 911 039 Two Way Pilot Hood N S 911 137 Pilot Hood Clip N S 904 658 Inlet Flex Line Gas SS Steel 610 mm long N S 904 606 Fitting 90 Street Elbow Extruded N S 904 165 Fitting 3 8 Male Flarex Mpt Strt Adaptor N S W840470 Pilot Assembly Gask...

Страница 78: ... Fireglass Starfire 6mm 454g Pkg N S 946 780 Crushed Glass Coal Black 19 mm 1 6kg N S 657 991 Chase Flue Flush Front White N S 946 710 Volcanic Stones Black Gray N S 946 711 Volcanic Stones Ivory Tan N S 656 950 Chase Steel Framing Kit Compact N S 656 951 Extended Chase Steel Framing Kit N S 656 952 Extended Hearth Steel Framing Kit N S 656 992 Chase Flue Sides Black 16 656 917 Inner Panel Black P...

Страница 79: ...City Series ACB40E 79 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...

Страница 80: ... Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts above have ex...

Страница 81: ...actice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the installation F...

Страница 82: ...expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any damage of this...

Страница 83: ...option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than services of a ki...

Страница 84: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 85: ...City Series ACB40E 85 notes 85 City Series ACB40E 11 ...

Страница 86: ...86 City Series ACB40E notes ...

Страница 87: ... following information Dealer Name Address __________________________________________ ______________________________________________________________ Installer _______________________________________________________ Phone _______________________________________________________ Date Installed ___________________________________________________ Serial No ______________________________________________...