background image

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.   

 

• Installation and service must be performed by a qualified installer, service agency or 

       gas supplier.

     Warning
Fire or Explosion Hazard
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

920-027j

    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

06.18.21

Bellavista

®

 

B41XTE 

Gas Fireplace

Owners & 

Installation Manual

MODELS: B41XTE-NG11

                 B41XTE-LP11

Installer:  

Please complete the details on the back cover and leave this 
manual with the homeowner.

Homeowner

Please keep these instructions for future reference.

Certified to/Certifié pour:   CSA 2.17-2017
                                          ANSI Z21.88-2017
                                          CSA 2.33-2017

Tested by: 

French Manual: https://bit.ly/3tqzAtw

Manuel en français : https://bit.ly/3tqzAtw

Содержание Bellavista B41XTE

Страница 1: ...rformed by a qualified installer service agency or gas supplier Warning Fire or Explosion Hazard Failure to follow safety warnings exactly could result in serious injury death or property damage 920 027j FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 06 18 21 Bellavista B41XTE Gas Fireplace Owners Installation Manual MODELS B41XTE NG11 B41XTE LP11 Installer Please...

Страница 2: ...tinuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position Each time the main burner shuts down manually or through the call from the thermostat the seven day timer starts again The seven day inactivity timer is controlled within the circuit board Therefore if in CPI mode and when the pilot light is extinguished after seven straight days of ina...

Страница 3: ... instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the...

Страница 4: ... Installations Rigid Pipe 5 x 8 38 Venting Arrangements for Horizontal Terminations 39 Unit Installation with Horizontal Termination 5 x 8 Venting Rigid Vent Systems 40 Unit Installation with Horizontal Termination 5 x 8 Venting Flex Vent Systems 41 AstroCap XL Dimensions 946 623 P 41 Vertical Terminations Three 90o Elbows Rigid Pipe 5 x 8 42 Venting Arrangements for Vertical Terminations 43 Unit ...

Страница 5: ...when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details Installer l appareil selon les codes ou règlements locaux ou...

Страница 6: ...rectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspe...

Страница 7: ...9mm 38 3 8 974mm 46 9 16 1183mm 2 7 16 61mm 1 15 16 49mm 36 3 8 924mm 49 1 8 1244mm 21 15 16 533mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS Note Gas connection is from the right hand side of the appliance electrical connection on left hand side of the appli ance A metal receptacle box is supplied insta...

Страница 8: ...ety Screen Dimensions with Vignette and Vignette Finishing Trim Note Gas connection is from the right hand side of the appliance electrical connection on left hand side of the appli ance A metal receptacle box is supplied installed with the appliance to make all 120 volt electrical connections ...

Страница 9: ... converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the ...

Страница 10: ...he air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and...

Страница 11: ...NSI Standards to make you aware of the following General Safety Information 1 The appliance installation must conform with lo cal codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must be electri cally grounded in accordance with local codes or in the absence of local codes with the curr...

Страница 12: ...roximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF b...

Страница 13: ...ler service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l in...

Страница 14: ...Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control m...

Страница 15: ...ight by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat ...

Страница 16: ...circulating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliar...

Страница 17: ...ntermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using the silver toggle switch located on the fireplace See noted location of CPI IPI Switch The benefits of having CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensation on start up Provides...

Страница 18: ...ore installation Installation Checklist 1 Locate appliance a Room location Refer to Locating Your Gas fireplace section b Clearances to Combustibles Refer to Clearances section c Mantle Clearances Refer to Combus tible Mantel Clearances section d Framing FinishingRequirements Refer to Framing Finishing section e VentingRequirements Referto Venting section 2 Assemble Top Standoffs and Top Facing Su...

Страница 19: ...nce that this fireplace and vent system be installed only in accordance with these instructions B41XTE Clearance Requirements Minimum Vent Clearances to Combustibles Horizontal Top 3 76mm Horizontal Side 2 51mm Horizontal Bottom 2 51mm Vertical Vent 2 51mm E F Alcove NOTE A 16 deep by the width of the appliance non combustible hearthpadisrecommendedwhenusinghardwoodflooringandcarpet Clearance Dime...

Страница 20: ...alled at a lower overall height may not be lower than 6 inches from the top of the fireplace opening Mantel Clearances B41XTE A B C D Flush Panels Safety Screen or Vi gnette Vignette Trim Stepped Finish From Top of Fireplace Opening 35 1 4 895mm 23 1 4 591mm 19 1 2 495mm 15 381mm Vignette with Vignette Finishing Trim Finished Flush From Top of Fireplace Opening 35 1 4 895mm 33 1 16 825mm 29 5 16 7...

Страница 21: ...4 1238mm Non combustible 41 3 4 1060mm Non combustible Material Non combustible Header steel stud on edge 47 1 4 1200mm Framing 36 3 4 933mm Min 3 1 2 89mm Non combustible Non combustible Vignette Vignette Finishing Trim Finished Flush Flush Panels with Safety Screen or Vignette Faceplate Vignette Finishing Trim Stepped Finish 3 sided Vignette trim 4 sided Vignette Trim 38 1 2 ...

Страница 22: ...iling Top 54 1 2 1384mm S Rear Vent Vent Centerline Height Rear 28 1 2 724mm S Top Vent Vent Centerline Height Top 47 1 2 1207mm Rigid Flex T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 5 127mm V Gas Connection Width 3 1 4 82mm W Non Combustible Top Height 13 1 2 343mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed heart...

Страница 23: ...O Rear Vent Framing Depth Rear Vent 24 7 8 632mm O Top Vent Framing Depth Top Vent 24 7 8 632mm P Corner Facing Wall Width 63 3 8 1610mm Q Corner Facing Wall Width 89 5 8 2276mm R Rear Vent Framed Chase Ceiling Rear 50 1 4 1276mm R Top Vent Framed Chase Ceiling Top 54 1 2 1384mm S Rear Vent Vent Centerline Height Rear 28 1 2 724mm S Top Vent Vent Centerline Height Top 47 1 2 1207mm Rigid Flex T Ga...

Страница 24: ...tion box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Receiv...

Страница 25: ...he base of the fireplace should be level or higher than the finished hearth height Note All non combustible facing material should butt up cleanly to the flanges around the firebox opening Rough edges will be visible from the front view with the flush louvers or flush panels if not using the optional finishing trim To maintain a clean finished edge it is recommended to install the non combustible ...

Страница 26: ...cing Support is reversed for C hole position A A B C B C Screw holes for Side Nailing Strip Top Facing Support Nail6 eps A B C Screw holes for Top Facing Support Top Facing Support is reversed for C hole position A B C Top Facing Support Side Nailing Strips The side nailing strips come attached to the unit There are 2 plates one on the top and bottom that can be folded out as required If finishing...

Страница 27: ...door frame 2 From inside the firebox remove the baffle plate by removing 4 screws remove top front screw first Baffle Plate 3 From the inside of the firebox remove the exhaust assembly by remov ing the 10 screws 7 From the outside top of the firebox remove the intake cover plate by removing the 4 1 4 x 1 2 screws 5 From the outside top of the firebox remove top insulation cover plate by removing 2...

Страница 28: ...rom inside the firebox re install the baffle plate from step 2 11 From the outside top of the firebox install the intake collar assembly Secure with 4 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten All 4 screws must be used Intake Collar Assembly Exhaust Assembly 8 From the outside top of the firebox completely remove the insulation under the cover plate as shown and discard ...

Страница 29: ... 4 x 1 2 screws Ensure all screws are tight but do not over tighten See diagram 2 SET 3 THIS HOLE SETS THE VENT RESTRICTOR AT 1 1 2 SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 2 1 2 SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 3 1 2 NO VENT RESTRICTOR Factory setting Baffle Plate Diagram 3 Diagram 1 Venting Introduction The B41XTE uses the balanced flue technology Co Axial system The inner liner ve...

Страница 30: ...er line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway locate...

Страница 31: ...al Support Box 58DVA CS 5DT CSS 5DRS TM 5SS DV CSS05 Wall Support Band 58DVA WS 5DT WS B 5DWS TM 5WS VDV WS05 Offset Support 58DVA ES 5DT OS N A TM 5OS N A Wall Thimble Black 58DVA WT 5DT WT 5DWT N A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CR...

Страница 32: ...or Must use with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the following units B41XTE B41XTCE CB60E CV60E C...

Страница 33: ...ding Standoff is required it must be usedwithvinylsiding measuretooutsidesurface of wall without siding and add 2 inches Alternate Snorkel Termination Cap HOT Alternate Horizontal Termination Caps Rigid Pipe Adaptor 770 994 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Pipe Length Pipe Length 90 Elbow o AstroCap XL Termination Cap Part 946 623 P Wall Thimble Mandatory in all...

Страница 34: ... 6 6 4 4 8 8 Vertical Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 2 0 0 6 6 4 4 8 8 2 2 0 0 6 6 4 4 8 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required Venting Arrangements for Horizontal Terminations Flex Vent or Rigid Pipe 5 x 8 Rear Venting Deflector Installation For Rear Vented Horizontal Terminat...

Страница 35: ...E with a either a top or rear vent Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from Regency may be used for Flex installations 3 Regency Direct Vent System Flex is only approved for horizontal terminations NOTE If longer runs are required the FPI DirectVent system Flex 946 616 includes all parts needed to install the B41XTE with a maximum 10 r...

Страница 36: ...Cap Wall Thimble Vinyl Siding Standoff Optional Horizontal Termination A Top Vent No Vertical Rise When venting with a 90 elbow directly off the unit Flex vent or approved Rigid Vent System Max 3 ft horizontal run B Rear Vent w Horizontal Termination Max 3ft horizontal run B A Horizontal Terminations Rigid Pipe 5 x 8 IMPORTANT Must use Rear Venting Deflector packaged with unit in rear vent horizon...

Страница 37: ... F 5 Min 7 Max G 6 Min 8 Max No Vent Restrictor Installed Lengths do not include elbow indicated Must use rigid pipe adaptor 770 994 One 90o elbow Two 45o elbows Option V H V V1 H H1 W i t h t h e s e options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Pleasenotemini mum 1 foot be tween 90o elbows is required A 0 Min 1 Max 1 Min 2 ...

Страница 38: ... Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 Galvanized Rigid Pipe 58DVA 06 1 8 1 2 Galvanized Pipe Extension 58DVA 08A 1 45º Galvanized Elbow 58DVA E45 1 90ml MillPac 948 128 28 1 2 724mm Placement of the Unit into the Corner Back Top Corner of Unit to Wall 3 Inside Corner out along the Wall 60 1 4 Across the Face of the Unit Wall to Wall 85 3 16 A Clearan...

Страница 39: ... 2 Restrictor 3 1 2 Open Set 1 Venting Arrangements for Horizontal Terminations The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing t...

Страница 40: ...inated See diagram 54 for center line requirements If the wall being penetrated is constructed of non combustible material i e masonry block or concrete an 8 203mm diameter hole is acceptable Notes a The horizontal run of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present...

Страница 41: ...Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90o The liners must slip over the collars a minimum of 1 3 8 7 Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner d...

Страница 42: ...e length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 0 Min 2 Min 2 Max B 1 Min 3 Min 2 Max C 2 Min 4 Min 3 Max D 3 Min 6 Min 4 Max E 4 Min 7 Min 5 Max F 5 Min 8 Min 6 Max G 6 Min 9 Min 7 Max H 7 Min 10 Min 8 Max Restrictor 2 1 2 open Set 2 Lengths do not include elbow indicated Must use rigid pipe ...

Страница 43: ... a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting to 3 1 2 opening 2 1 2 opening and to 1 1 2 opening Note Must use optional flue adapter when using Rigid Pipe Part 770 994 Minimum 8 2 4m Min 47 1 2 1 2m 0 0 2 2 4 4 6 6 40 40 8 8 10 10 12 12 14 14 16...

Страница 44: ...where the vent will penetrate the roof 3 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in a flat ceiling or wall cut a 11 inch square hole Frame the hole as shown in Diagram 2 and install the firestop 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow connections are in the fully twist locked position and se...

Страница 45: ...ipe to pipe adaptor using Mill Pac over the adaptor Slide the inner pipe over the flex to rigid adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex 3 Cut a hole in the roof centered on the small hole placed in the roof in the previous steps The hole should be a minimum of 11 279 mm The hole may be round and or square 4 Slip the flashing under the shingles and line up flashing s...

Страница 46: ...ed separately See Simpson Duravent components list in the instruction manual for part numbers Flex Pipe Ceiling Firestop Roof Support Brace Flashing Storm Collar Termination Cap Ceiling Firestop Enclosure Flex Pipe Ceiling Firestop Roof Support Flashing Elbow Support Termination Cap Storm Collar Ceiling Firestop Support to prevent sagging Enclosure Ceiling firestop Flashing Termination Cap Storm C...

Страница 47: ...flex adapter and slip the 5 127 mm inner flex pipe from the Vertical termination kit over the flex adapter ensuring that the inner flex pipe overlaps the collar by at least 1 4 35 mm Fasten with 3 screws 4 Apply a bead of Mill Pac around the perimeter of the 8 203 mm outer collar of the flue adapter and slip it over the 8 203 mm outer flex pipe from the vertical termination kit ensuring that the o...

Страница 48: ... 946 757 Used in conjunction with the 946 755 Vertical flex kit and 946 756 kit Vertical flex extension kit Horizontal power vent kit Firestop spacer to prevent debris from falling into the ceiling firestop Aceiling firestop firestop spacer must be installed when passing through each floor orceiling level Toinstall theceilingfirestop firestop spacer in a flatceiling or floor joist cut a 279 mm squ...

Страница 49: ...lat screwdriver Note Screw should be snug but do not over tighten High Elevation This unit is approved in Canada for altitude to 4500 ft CAN CGA 2 17 M91 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 B41XTE NG11 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 30 Max Input Rating 42 500 Btu h Min Input Rating 30 000 Btu h Supply Pressure min 5 0 w c Ma...

Страница 50: ... shown Position the left brick panel in place and secure with the brick panel clip and screw removed from the firebox as shown below 6 Slide the top brick panel under the left or right side panel which ever is installed first right side panel shown here and back brick panel use care not to damage panel Left Panel Right Panel Back Panel Top Panel Back Panel Installed 7 Install the remaining side pa...

Страница 51: ...not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty 1 Prior to installation of the reflective panels remove the top panel bracket ...

Страница 52: ...ighten the screw Location of screw A 6 Install left side panel repeat step 4 5 Slide top panel under the top of the back and right side panels as shown below Top panel bracket shown installed with Stainless Steel Panels 7 Carefully position and fit the top bracket in place by ensuring the tabs of the bracket fit into the baffle openings as shown below Push downwards to secure the bracket to the to...

Страница 53: ... pieces A Rear Bottom Right Log B Rear Top Left Log C Right Top Cross Log D Front Log Piece E Left Top Cross Log F Center Right Log G Front Bottom Right Log H Front Bottom Left Log I Center Left Log 902 156 Lava Rocks 902 179 Vermiculite 946 669 Platinum Embers supplied w packaged manual 1 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care do not for...

Страница 54: ...n below 8 Slide the left side of Log H back until it touches the tab on the burner shown below 10 Slide the right side of Log G back until it touches the tab on the burner shown below I H G 9 Place Log G on the right front side of the burner in front of log F Position Log G so it fits into the pin on the burner as shown below There is a notch on the bottom of log G position the log so the notch fi...

Страница 55: ... below 13 Position Log B on top of Log A Log B fits into the pin in Log A Ensure Log B sits upright 90 degrees with the left side of the log resting on the notch in Log E See next 2 diagrams 14 Position Log C on top of Log G Log C fits into the pin in Log G as shown below E H E A A B C 15 With Log C in position on Log G assure that Log C contacts the back corner of Log A as shown below C A E B Dia...

Страница 56: ...latinum Embers Diagram 19 17 Separate platinum embers and place on the front burner on and around the lava rocks Avoid stacking platinum embers Platinum embers may be placed over burner ports IMPORTANT Do not cover burner ports with lava rocks as this will change the flame pattern 16 Place the lava rocks on the burner in front of the logs as shown below Be careful not to overlap the lava rock and ...

Страница 57: ...re a 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power failure the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circ...

Страница 58: ...t be disconnected IMPORTANT Recommend removing the 4 AA batteries in the SureFire receiver This will avoid battery leakage and power drainage 4 AA Battery pack may be re installed into receiver during power outages 919 063 10 09 14 1 Plug AC adaptor into a 120V wall outlet or into the 120V receptacle if installed inside the gas fireplace 2 Tuck any loose wires neatly underneath the firebox inside ...

Страница 59: ...ed 2 Remove the mesh barrier and the standard flush door 3 Remove fan assembly from box locate green ground wire and pull out of fan assembly taking care not to damage or cut wire casing 4 Position the fan base with the motor end towards the rear of the firebox and then slide the fan in towards the rear of the unit Turn the fan housing slightly to the left and make the fan assembly paral lel to th...

Страница 60: ...the bracket clip on the left underside of the firebox Ensure that no wires will touch hot surfaces 11 Plug in the fan power cord to the Fan Control Module into the outlet marked Fan Plug the FCM COM wire from the remote control wiring harness into the location on the Fan Control Module marked COM Turn the switch on the Fan Control Module to the ON posi tion ON is to the left The O is the off posit...

Страница 61: ...ing Diagram with Optional Fan SureFire Switch CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges 0 584 622 ...

Страница 62: ...s will be located near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade con nector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step 1 using a female spade connector see picture below When complete turn remote receiver to...

Страница 63: ...rews Tighten the 2 screws to secure in place Finishing Trim Edge of Unit B41XTE B36XTE W 43 3 8 40 1 2 H 37 5 8 35 3 4 Optional Finishing Trim Installation Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See Diagram 3 Diagram 2 The standard flush door comes with a black frame To install the frame simply hook th...

Страница 64: ...ppliance Slide the top of the frame See Detail AA above on to the screws See Detail A shown above AA A 5 Lower bottom end of frame Detail BB gently into bottom of bracket Detail B BB B 6 Lineupthetabsonthescreenassemblywiththeslotsintheouterframe andlowergentlyintoplace Bringbottomofthescreenassemblytoward the front of the appliance until it comes into contact with the magnets 7 Reverse the steps ...

Страница 65: ...ition the Inlay so it is exactly centered from side to side and top to bottom within the Inner Vignette Frame 4 With the top of the Inlay in correct position push the studs at the bottom of the Inlay through the actual screen NOTE Ensure Inlay is in correct position before pushing studs through the safety screen 5 Secure the Inlay in position with supplied brackets washers and nuts as shown Bracke...

Страница 66: ...om bracket slots over the screws Tighten the 4 screws to secure 5 Hook Vignette Faceplate brackets into place 6 Line up the screw holes on the finishing trim and Vignette Face plate bracket with the unit fasten with 2 screws on each side 8 Hook Vignette Faceplate brackets into place see specific instructions in unit manual 7 Install the lower finishing trim if required secure with four screws Comp...

Страница 67: ... screws as shown below 3 Flip the hinges down to 90 line up the lower premium front as shown below 4 Fasten the hinges to the flush panel with 2 screws each as shown below 5 Flip up the louver flush panel to close 6 To install the top premium frontl line up the 2 tabs on the louver flush panel with the corresponding bracket clip on the inside top of the unit see below Flush Panel Installation Must...

Страница 68: ...ass door frame two 2 magnets located on inside lower part of the screen frame will secure the screen to the glass door frame 3 To remove reverse steps Magnet locations SAFETY SCREEN INSTALLATION MUST BE USED WITH OPTIONAL PREMIUM FRONT 1 Hook the safety screen frame onto the unit in locations shown below 2 Gently lower screen on to glass door frame two 2 magnets located on inside lower part of the...

Страница 69: ...ome very difficult to remove Use a non abrasivecleanerandNEVERclean the glass while it is hot First Fire The first fire in your fireplace is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on Whenfirstoperated theunitwillreleaseanodour caused by the curing of ...

Страница 70: ...ere is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if using optional rem...

Страница 71: ...ied installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétai...

Страница 72: ...placement glass Part 940 362 P is shipped already installed into the door frame Reinstall as per Glass Door Installation in the Glass Door Removal section Maintenance Instructions 1 Alwaysturnoffthegasvalvebeforecleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean ...

Страница 73: ...5 Diagram 4a Diagram 4b Diagram 3 Diagram 7 Installing Valve 1 Place new valve tray and gasket into position 2 Reinstall the 14 hold down screws 3 Connect the EV1 EV2 and ground wires to the appropriate connections on the valve 4 Reinstall the rear log tray 5 Install burner grate assembly 6 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not us...

Страница 74: ... list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should ...

Страница 75: ...g Door Extension 14 940 362 P Ceramic Glass w Gasket 15 509 083 Door Frame 16 Outerbox Assembly 17 Firebox Assembly Part Description 18 509 917 Fan Assembly 19 910 215 P Fan Motor 120 Volts 20 509 922 Vignette Faceplate Platinum 509 923 Vignette Faceplate Black Chrome 509 924 Vignette Faceplate Black 509 926 Vignette Faceplate Tuscan Sunset 509 918 Vignette Door Inlay Black Chrome 509 919 Vignette...

Страница 76: ...ame Sensor 911 038 Flame Electrode Part Description 904 660 Orifice 30 NG 904 431 Orifice 49 LP 9 509 574 E P Valve Assembly NG 509 776 E P Valve Assembly LP 506 003 Valve Assembly Gasket 911 265 Ignition Board DBC 911 013 Wiring Harness Switch 911 127 Battery Compartment Door Receiver 911 018 Battery Holder 14 911 039 Pilot Hood 911 137 Pilot Hood Clip 910 432 Pilot Tube 911 228 P Remote Receiver...

Страница 77: ...ed Finishing Trim flush Panels only 4 506 901 Brick Panels Standard Brown 506 902 Brick Panels Standard Red 506 905 Brick Panels Standard Charcoal Gray 5 506 908 Inner Panels Black Enamel 601 170 Top Front Brick Retainer 511 031 Brick Clip Each Part Description 6 506 916 Flush panels 7 509 929 Safety Screen ...

Страница 78: ...ntrol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory asse...

Страница 79: ...afts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the app...

Страница 80: ...the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a br...

Страница 81: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Страница 82: ...82 Regency Bellavista B41XTE 11 Gas Fireplace warranty ...

Страница 83: ...Regency Bellavista B41XTE 11 Gas Fireplace 83 ...

Страница 84: ..._____________________________ Phone ______________________________________________________ Date Installed _________________________________________________ Serial _______________________________________________________ Printed in Canada Regency Bellavista AstroCap and SureFire are trademarks of FPI Fireplace Products International Ltd Copyright 2021 FPI Fireplace Products International Ltd All rig...

Отзывы: