B41XTCE Gas Fireplace

The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system.

A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.

For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum 

continuous

 vent length of 10ft (3.0m). 

Note:  Must use optional rigid pipe adaptor (Part # 770-994) when using  Rigid Pipe vent systems.

•   Maintain clearance to combustibles.

•   Horizontal vent must be supported every 3 feet.

•   Firestops are required at each floor level and whenever passing through a wall.

2

0

12

6

4

8

10

2

0

6

4

8

Vertical

Height

(Feet)

Rigid

or

Flex

47-1/2"

(1.2m)

Horizontal (Feet)

Max. 36 (0.9m)

2

0

6

4

8

2

0

6

4

8

Vertical

Height

(Feet)

28

-1/2"(0.7m)

Horizontal (Feet)

Max. 36"(0.9m)

Vent Restrictor - Set 1

Factory Setting - No Restrictor Required

VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS 

FLEX VENT OR RIGID PIPE 5" X 8"

REAR VENTING DEFLECTOR INSTALLATION

FOR REAR VENTED HORIZONTAL TERMINATIONS

Rear Venting Deflector

The Rear Vent Deflector comes with the unit. When the unit is shipped 

the deflector is slightly tucked underneath the top nailing strips located 

at the top of the firebox.

NOTE:

 The Rear Venting Deflector must be installed before the unit is 

put in place. 

IMPORTANT

Must use Rear Venting Deflector packaged with unit in 

rear vent horizontal termination applications.

Rear Venting

Deflector

1)

   Secure  the  rear  venting 

deflector to the wall thimble 

using  2  screws  as  shown. 

Ensure to use the same screw 

holes as the wall thimble.

Содержание Bellavista B41XTCE

Страница 1: ...aming height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth Approved Venting Systems Flex Vent Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Direct Vent Pro Selkirk Direct Temp Metal Fab Sure Seal ICC Excel Direct Vent Framing Dimensions Description B41XTCE M Framing Width 47 1 4 1200mm N Framing Height 49 1 2 1257mm O Rear Vent Fram...

Страница 2: ... required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 9 16 446mm Top of Fireplace Opening B Sidewall 9 229mm Side of Fireplace Opening C Ceiling 36 5 8 930mm Top of Fireplace Opening D Mantel Depth max 12 304mm 25 13...

Страница 3: ...on combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A B C Non combustible Header steel stud on edge 14 To Floor 12 24 Inches D 6 Non combustible Standoff Mantel Clearances B41XTCE A B C D From Top of Fireplace Opening 32 11 16 830mm 25 13 1...

Страница 4: ...e finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below CLEAN FINISH 6 If applying a non combustible facing it may be installed over the metal surface clean front of the unit in the area shown below Combustible and Non combustible Facing and Finishing Materials around unit 38 7 16 976mm 29 737mm Combustible M...

Страница 5: ...anel NOTE Non combustible finishing materials may be of any thickness desired Minimum Clearances for Finishing Materials Trim materials Note All non combustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both mater...

Страница 6: ...Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 0 6 4 8 2 0 6 4 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5 X 8 REAR VENTING DEFLECTOR INSTALLATION FOR REAR VENTED HORIZONTAL TERMINATIONS Rear Venting Deflector The Rear Vent ...

Страница 7: ...iagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with Rigid Pipe Venting Systems for Propane and Natural Gas Two 45o elbows equal to one 90o elbow Maximum of four 45o elbows allowed Minimum 8 2 4m Min 47 1 2 1 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 Horizontal Feet 2 0 4 10 12 Restric...

Отзывы: