B41XTCE Gas Fireplace

32-7/8"

835mm

25

-5

/8"

[65

1m

m

]

NO FACING OR

FINISHING MATERIAL

IN THIS AREA

No Combustible

Materials in this Area

41

-5

/8"

[10

57

m

m

]

40-5/8"

[1031mm]

4-1/8"

[105mm]

8-3/8"

[213mm]

3-7/8"

[98mm]

3-1/2"

[89mm]

Non combustible - supplied w/unit

J Style trim or metal

corner bead may be

used to finish edges

No Combustible

Materials in this Area

29

"

[73

7m

m

]

38-7/16"

976mm

7.

  Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this 

will assure ease of glass door removal and access to the lower panel.

 
 

NOTE:

  Non-combustible finishing materials may be of any thickness desired.

 

Minimum Clearances for Finishing Materials

Trim materials

Note:

  

All non-combustible facing material should butt up cleanly     
to the flanges around the firebox opening.  

      
      Rough edges may be visible from an angle. 
      
      To maintain a clean finished edge - facing material edges 

may be finished with a J-style trim or metal cornerbead (both 
materials available at your local building or hardware store).

IMPORTANT:

 Materials used must be NON-COMBUSTIBLE.

IMPORTANT FINISHING DETAIL NOTE:   

        

Before placing unit into final position - it is important to know the total 

thickness / height of finished hearth (tile, carpet, etc.)  The base of the 

fireplace, 4 sided faceplate or mantel should be level or higher than the 

finished hearth height.

Содержание Bellavista B41XTCE

Страница 1: ...aming height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth Approved Venting Systems Flex Vent Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Direct Vent Pro Selkirk Direct Temp Metal Fab Sure Seal ICC Excel Direct Vent Framing Dimensions Description B41XTCE M Framing Width 47 1 4 1200mm N Framing Height 49 1 2 1257mm O Rear Vent Fram...

Страница 2: ... required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 9 16 446mm Top of Fireplace Opening B Sidewall 9 229mm Side of Fireplace Opening C Ceiling 36 5 8 930mm Top of Fireplace Opening D Mantel Depth max 12 304mm 25 13...

Страница 3: ...on combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A B C Non combustible Header steel stud on edge 14 To Floor 12 24 Inches D 6 Non combustible Standoff Mantel Clearances B41XTCE A B C D From Top of Fireplace Opening 32 11 16 830mm 25 13 1...

Страница 4: ...e finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below CLEAN FINISH 6 If applying a non combustible facing it may be installed over the metal surface clean front of the unit in the area shown below Combustible and Non combustible Facing and Finishing Materials around unit 38 7 16 976mm 29 737mm Combustible M...

Страница 5: ...anel NOTE Non combustible finishing materials may be of any thickness desired Minimum Clearances for Finishing Materials Trim materials Note All non combustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both mater...

Страница 6: ...Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 0 6 4 8 2 0 6 4 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5 X 8 REAR VENTING DEFLECTOR INSTALLATION FOR REAR VENTED HORIZONTAL TERMINATIONS Rear Venting Deflector The Rear Vent ...

Страница 7: ...iagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with Rigid Pipe Venting Systems for Propane and Natural Gas Two 45o elbows equal to one 90o elbow Maximum of four 45o elbows allowed Minimum 8 2 4m Min 47 1 2 1 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 Horizontal Feet 2 0 4 10 12 Restric...

Отзывы: