2) Output current
2016-08-05
272/330
V04.52
9
9.1.3.
2) Output current
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
3-1
20
i2t
Calculated loss energy [(Ilimit)2
–
(Iout)2] * t exceeds the limit I2tmax..
Current during some time exceeds
current limit.
Adjust the current llimit or l^2t to load
3-2
21
Overcurrent Isek
Output current exceeds the set level
during a particular delay time.
Controller overshooting caused by
set value steps.
Decrease steps of set value ramp.
Adapt controller parameters to the load.
3-2
21
Overcurrent Isek
Output current exceeds the set level
during a particular delay time.
Controller overshooting
Decrease controller parameters
3-2
21
Overcurrent Isek
Output current exceeds the set level
during a particular delay time.
Strong additional switching on of a
low resistive load produces a cur-
rent peak (result of the output
capacitance).
A temporary voltage drop is reduced by adding an
exter-nal capacitor or a serial in-ductance.
After a consultation with customer support, where
appropriate, increase the delay.
3-3
22
Overcurrent Iprim
The transformer current exceeds the
preset level (Level is dependent on
the temperature).
Controller overshooting by set
value jumps.
Reduce the gradient of the set value ramp.
Decreasing controller parameters.
3-3
22
Overcurrent Iprim
The transformer current exceeds the
preset level (Level is dependent on
the temperature).
Strong additional switching on of a
low resistive load (fast and large
voltage drop).
A temporary voltage drop is reduced by applying
a exter-nal capacitance or serial inductance.
Decrease of controller parameters.
3-3
22
Overcurrent Iprim
The transformer current exceeds the
preset level (Level is dependent on
the temperature).
Hardware defect.
Contact customer support
3-4
23
Gatedrive A fault
Hardware current monitoring. Detec-
tion of short circuits with immediate
switching off the power stage.
Cf. “22) Overcurrent Iprim“
Cf. “22) Overcurrent Iprim“
3-5
24
Gatedrive B fault
Hardware current monitoring. Detec-
tion of short circuits with immediate
switching off the power stage.
Cf. “23) Overcurrent Iprim“
Cf. “23) Overcurrent Iprim“
3-6
25
Overcurrent Isek
(level de-rated by
tem-perature)
Cut-off level of current was reduced
because of high temperature (from
110% to 100% device maximum
current) Cf. 21)
Cf. „21) Overcurrent Isek“
Lower ambient temperature and/or
cf.
„21) Overcurrent Isek“