Regal-Seton APPROX 4 Скачать руководство пользователя страница 6

- 6 - 

10. bASE (Base) – Save or recall default settings 

It is possible to store all the configurations of the unit into the storage device, and recall them 
whenever required (this function can be really useful, if e.g. we use the unit often in the same 
way). 
To access to the menu press ENTER twice, while flashing warning sign can be seen on the 
display.  
-

 

In 

LOAd

 submenu pressing ENTER twice (flashing warning sign), the stored 

configuration into the storage device overwrites all the actual settings. 

 

Attention!!! Once the second ENTER has been pressed you lose all the actual settings. 

-

 

In 

SAUE

 (save) submenu pressing ENTER flashing sign warns that you are going to 

overwrite the default configurations in the storage device. Overwriting can be carried out 
by pressing UP and DOWN simultaneously. 

Attention!!! The actual settings overwrite the default configuration, and you lose the 
former configuration for good.

 

 

11. dISP (Display) – Set display’s brightness 

Approx 4 offers the possibility to set the brightness of the display in 10 phase (

0-9

) at status 

feedback. Entering the menu the horizontal lines at the place of the second character show the 
brightness which can be reached with the given phase. To turn the display off choose phase 

0

Independently of the phase chosen the menu and the error messages appear at full brightness. 

  

12. t °C (Temperature) – Measure temperature 

In the two main blocks of the unit temperature sensors are built in. Using this function (

ON

Approx 4 displays the heat measured in both blocks every minute. 
-

 

Exceeding 100 °C the measured value flashes on the display at full brightness.  

-

 

Exceeding 105 °C in any block the unit switches its channels off, cooling back under 100 
°C it will switch the channels on automatically. 

Avoiding heat protection (

OFF

) it is the operator’s responsibility to handle thermal problems 

and consequences.   

 

13. Conn (Connection) – Use of master/slave mode 

Using the units without a lighting controller it is also possible to operate them simultaneously. 
In 

Conn

 menu one of the units can be decided to operate as a master unit (

MAS

) , the rest as 

slave units (

SLAU

). So it is enough to set the chase and its parameters just in the master unit, 

the others will do the same. 
Choosing 

Off

 master/slave can be switched off. 

 

14. CHAS (Chase) – Edit or modify a Chase  

Approx 4 has 9 preset, 3 logically editable and 1 level-memory (scale of 10%) editable 
chases. Putting the unit in operation for the first time the editable chases are empty. 
 

Содержание APPROX 4

Страница 1: ...APPROX 4 User s Manual DMX Contorlled Dimmer bar...

Страница 2: ...4 Limit 3 5 Switch dimmer 3 6 Channel enabling 4 7 Backup patch 4 8 Equalization curves 4 9 Hold 4 10 Default settings 5 11 Display 5 12 Heat protection 5 13 Master slave 5 14 Chase 5 14 1 Standard c...

Страница 3: ...wish to use different type of lamps you must carry out the necessary settings in the menu before connecting the lamps Supplying power Approx 4 switches its channels on one by one with a 0 25sec delay...

Страница 4: ...n 256 steps On the display the serial number of the decimal points shows the channel being set In PrAll submenu after pressing ENTER a flashing warning sign appears pressing ENTER again set starts fro...

Страница 5: ...standard chase activates At status feedback the decimal points run on the display two short impulses deletes the backup scene or chase has been chosen The unit operates in buffer data storing again 8...

Страница 6: ...ow the brightness which can be reached with the given phase To turn the display off choose phase 0 Independently of the phase chosen the menu and the error messages appear at full brightness 12 t C Te...

Страница 7: ...a maximum of 30 steps Entering to edit A b or C chase a label LEUE level appears on the display for a second then the maximum output levels dedicated to the 4 channels can be seen Here it is possible...

Страница 8: ...mode S channel switched off H channel switched on Channel put out operation o channel put out operation Feedback of decimal points no decimal point lit the unit operates in buffer data storing the 4...

Страница 9: ...f parts in the socket can not be repaired for operating bigger systems a spare block is recommended In case of a fault in the control block or other faults contact your retailer Technical specificatio...

Страница 10: ...10...

Отзывы: