- 4 - 

Menu 

 

1. Ch (Channel) – Set DMX addresses 

Each channel’s DMX address can be set  from 1 to 512. (More channels can have the same 
DMX address.) UP/DOWN are used to assign the values to the channels. On the display the 
decimal point of the character dedicated to the channel being set is lit.

 

In

 

CAdd

 submenu operators can set the starting address of the unit. In this case, this is the 

address of the first channel, and Approx 4 automatically sets the rest of the channel’s 
addresses one-by-one in numerically rising order . To access 

CAdd

 submenu press ENTER 

twice, while a flashing warning sign can be seen on the display. Once starting address has 
been set and ENTER pressed the unit carries the serial patching  out. In 

CAdd

 mode all the 

decimal points are lit.  

Attention!!! Serial patching overwrites the values set one-by-one.

  

 

2. SIdE (Side) – Invert channels 

This function is used to transpose the channel order. Entering the menu, operators can choose 
between normal (

nor

) or inverted (

Inv

) mode. (Application e.g. for symmetric stage scene.)   

 

3. Pr (Preheat) – Set preheat values 

Channel’s preheat values can be set one-by-one or together from 0 to 100 per cent in 256 
steps. On the display the serial number of the decimal points shows the channel being set.  
In 

PrAll 

submenu after pressing ENTER a flashing warning sign appears, pressing ENTER 

again set starts from the lowest preheat value of the 4 channels. 

 

 

4. Li (Limit) – Set maximum output levels  

Channel’s maximum values can be set one-by-one or together from 100 to 0 per cent in 256 
steps. On the display the serial number of the decimal points shows the channel being set.  
In 

LiAll 

submenu after pressing ENTER a flashing warning sign appears, pressing ENTER 

again set starts from the lowest maximum value of the 4 channels. Limitation value overrides 
the preheat value. If the limit’s value is lower than the preheat’s, obviously there is no real 
operating range, and an error message can be seen on the display: the decimal point dedicated 
to the channel flashes.  

 

5. Suu (Switch) – Choose switch or dimmer mode 

Operators can choose dimmer (

OFF

) or switch (

ON

) operating mode for each channel. 

The decimal point dedicated to the channel being set is lit. 
In switch mode the channel has two clear-cut thresholds (at the value of 240 or above it is on; 
at 15 or below it is off). 
In switch mode there is no preheat, but once the preheat value has been set to the channel it 
remains stored, so as you return to dimmer mode the stored preheat value is active again.  

Содержание APPROX 4

Страница 1: ...APPROX 4 User s Manual DMX Contorlled Dimmer bar...

Страница 2: ...4 Limit 3 5 Switch dimmer 3 6 Channel enabling 4 7 Backup patch 4 8 Equalization curves 4 9 Hold 4 10 Default settings 5 11 Display 5 12 Heat protection 5 13 Master slave 5 14 Chase 5 14 1 Standard c...

Страница 3: ...wish to use different type of lamps you must carry out the necessary settings in the menu before connecting the lamps Supplying power Approx 4 switches its channels on one by one with a 0 25sec delay...

Страница 4: ...n 256 steps On the display the serial number of the decimal points shows the channel being set In PrAll submenu after pressing ENTER a flashing warning sign appears pressing ENTER again set starts fro...

Страница 5: ...standard chase activates At status feedback the decimal points run on the display two short impulses deletes the backup scene or chase has been chosen The unit operates in buffer data storing again 8...

Страница 6: ...ow the brightness which can be reached with the given phase To turn the display off choose phase 0 Independently of the phase chosen the menu and the error messages appear at full brightness 12 t C Te...

Страница 7: ...a maximum of 30 steps Entering to edit A b or C chase a label LEUE level appears on the display for a second then the maximum output levels dedicated to the 4 channels can be seen Here it is possible...

Страница 8: ...mode S channel switched off H channel switched on Channel put out operation o channel put out operation Feedback of decimal points no decimal point lit the unit operates in buffer data storing the 4...

Страница 9: ...f parts in the socket can not be repaired for operating bigger systems a spare block is recommended In case of a fault in the control block or other faults contact your retailer Technical specificatio...

Страница 10: ...10...

Отзывы: