K factor (fault ride through)
REFUset
can be downloaded from
Pos : 63 /I nverter M anuals/ Konfig urati on/Kommuni kati on über Et hernet/ Einl eit ung/ WR @ 1\ mod_1405076335905_641. doc x @ 7132 @ 2 @ 1
6.5
Communication via Ethernet
The settings for the Ethernet communication can take place either manually or automatically (via DHCP).
Manually is the default setting.
Pos : 64 /I nverter M anuals/ Konfig urati on/Kommuni kati on über Et hernet/ Automatisc he Eins tell ung über DHC P/ WR @ 1\ mod_1405076399568_641. doc x @ 7138 @ 3 @ 1
6.5.1
Automatic Setting via DHCP
1. Navigate to Menu Configuration > Communication > Ethernet > DHCP.
2. Enter 1 in DHCP input field.
3. Press OK to confirm.
4. Restart inverter by opening and re-closing the DC switch.
The settings for IP address, subnet mask, standard gateway and DNS are automatically taken from
the DHCP server, e.g. the router.
Pos : 65 /I nverter M anuals/ Konfig urati on/Kommuni kati on über Et hernet/M anuelle Einst ellung/WR @ 1\ mod_1405076466442_641. doc x @ 7144 @ 3 @ 1
6.5.2
Manual Setting
In order to ensure a trouble-free operation, all values must be given by the responsible network
administrator and individually set in each inverter.
1. Navigate to Configuration > Communication > Ethernet > IP address.
2. Enter IPv4 address. The IPv4 address is arbitrary, but must be consistent throughout the subnet.
Default value:
192.168.130.30
3. Press OK to confirm.
4. Navigate to Configuration > Communication > Ethernet > Subnet mask.
5. Enter IPv4 mask. The IPv4 mask is arbitrary, but must be consistent throughout the subnet Default
value:
255.255.0.0
6. Press OK to confirm.
7. Navigate to Configuration > Communication > Ethernet > Standard gateway.
8. Enter the address of the router that allows connection to the internet
Default value:
192.168.1.1
9. Press OK to confirm.
10. Navigate to Configuration > Communication > Ethernet > DNS.
11. Enter arbitrary IPv4 address of the superior DNS server
Default value:
0.0.0.0
12. Press OK to confirm.
13. Restart inverter.