Error List
REFUsol 100K
982059/02
2020-11
En
gl
is
h
D
eu
ts
ch
900A3
SafetyRelay 1 broken
The safety relay L1 is jammed.
▸
Please contact REFU Service.
900A4
SafetyRelay 2 broken
The safety relay L2 is jammed.
900A5
SafetyRelay 3 broken
The safety relay L3 is jammed.
900A6
MainRelay 1 broken
The safety relay L1 is jammed.
900A7
MainRelay 2 broken
The safety relay L2 is jammed.
900A8
MainRelay 3 broken
The safety relay L3 is jammed.
900AA
External FAN NOK
The external fans do not work. The device au
-
tomatically limits its power to keep the tem
-
perature of the device within a safe range.
▸
Replace the external fans according to the
manual.
900AB
Internal FAN NOK
The internal fan does not work. The device au
-
tomatically limits its power to keep the tem
-
perature of the device within a safe range.
▸
Please contact REFU Service.
900AC
Systemstart info
–
No action necessary.
A017D
Phase defect
The actual current value deviates from the set
current value.
▸
Please contact REFU Service.
A017E
HW error activation
General hardware shutdown by the inverter
during the activation phase. This error should
be corrected automatically.
▸
If error occurs more than once, contact
REFU Service.
Error Code Message