A9MA03EN 02/2012

7

About the Book

At a Glance

Document Scope

This manual is intended for designers and installers of control systems and electrical protection systems.

Validity Note

Reflex iC60 integrated control circuit breakers are used for remote control and protection of installations 
via either electrical control or PLC control.

Related Documents

You can download these technical publications and other technical information from our website at 
www.schneider-electric.com.

User Comments

We welcome your comments about this document. You can reach us by e-mail at techcomm@schneider-
electric.com.

Title of Documentation

Reference Number

Instruction Sheet for Reflex iC60 integrated control circuit breakers

S1B8674701

Содержание iC60H

Страница 1: ...A9MA03EN 01 www schneider electric com Reflex iC60 Integrated Control Circuit Breaker A9MA03EN 02 2012 Reflex iC60 Integrated Control Circuit Breaker iC60 Circuit Breakers Reference Manual 02 2012...

Страница 2: ...y suggestions for improvements or amendments or have found errors in this publication please notify us No part of this document may be reproduced in any form or by any means electronic or mechanical i...

Страница 3: ...14 Connection 16 Chapter 3 Use 21 Operating Modes 22 Selection of the Operating Mode 28 Automatic Overheat Protection for the Reflex iC60 Integrated Control Circuit Breaker 31 Operation 32 Chapter 4 A...

Страница 4: ...4 A9MA03EN 02 2012...

Страница 5: ...ards or to call attention to information that clarifies or simplifies a procedure PLEASE NOTE Electrical equipment should be installed operated serviced and maintained only by qualified personnel No r...

Страница 6: ...6 A9MA03EN 02 2012...

Страница 7: ...d protection of installations via either electrical control or PLC control Related Documents You can download these technical publications and other technical information from our website at www schne...

Страница 8: ...8 A9MA03EN 02 2012...

Страница 9: ...N 02 2012 9 1 Reflex iC60 Integrated Control Circuit Breaker Introduction A9MA03EN 02 2012 Introduction What s in this Chapter This chapter contains the following topics Topic Page Overview 10 Descrip...

Страница 10: ...flex iC60 integrated control circuit breaker with Ti24 interface Catalog numbers of Reflex iC60N integrated control circuit breakers with Ti24 interface Catalog numbers of Reflex iC60N integrated cont...

Страница 11: ...P Tripping curves Rating B C D B C D B C D 10 A A9C64210 A9C65210 A9C66210 A9C64310 A9C65310 A9C66310 A9C64410 A9C65410 A9C66410 16 A A9C64216 A9C65216 A9C66216 A9C64316 A9C65316 A9C66316 A9C64416 A9...

Страница 12: ...h Ti24 interface A 230 V AC power supply terminal block B Y1 Y2 control input terminal block C Terminal block for the circuit breaker pole position open closed indication contact D Terminal block for...

Страница 13: ...N 02 2012 13 2 Reflex iC60 Integrated Control Circuit Breaker Installation A9MA03EN 02 2012 Installation What s in this Chapter This chapter contains the following topics Topic Page Assembly 14 Connec...

Страница 14: ...circuit breaker using a screwdriver 4 Assemble the Vigi iC60 auxiliary with the Reflex iC60 circuit breaker 5 Place the assembly on the DIN rail and push in the 5 locking clips 6 Push the padlocking...

Страница 15: ...Vigi iC60 auxiliary with the Reflex iC60 circuit breaker 5 Place the assembly on the DIN rail and push in the 3 locking clips 6 Push the padlocking device back in auto OFF Reflex iC60N 1 Ready Mode1 2...

Страница 16: ...assume that all circuits are live until they have been de energized tested and labeled Pay particular attention to the design of the power supply circuit Take account of all power supply sources incl...

Страница 17: ...contact F Local control auto OFF Reflex iC60N A B D C F Ready Mode1 2 3 I ON O OFF Overheat 12 11 14 21 22 24 O C auto OFF Y1 Y2 N P Terminal Function N Neutral P Phase Terminal Function Y1 Mode 1 loc...

Страница 18: ...g edge Mode 3 centralized closing control on rising edge and opening control on falling edge 24 V 24 V DC power supply Terminals Function 0 5 25 A Power 32 63 A Power Item Terminal block Tightening to...

Страница 19: ...rcuit breaker with Ti24 interface used in mode 1 2 or 3 The following diagram illustrates connection of a Reflex iC60 integrated control circuit breaker with Ti24 interface used in mode 3 N P P N Y1 Y...

Страница 20: ...iC60 integrated control circuit breaker via a 24 48 V AC DC output The following diagram illustrates connection of the control inputs on a Reflex iC60 integrated control circuit breaker using iMDU aux...

Страница 21: ...eaker Use A9MA03EN 02 2012 Use What s in this Chapter This chapter contains the following topics Topic Page Operating Modes 22 Selection of the Operating Mode 28 Automatic Overheat Protection for the...

Страница 22: ...24 A9C6 with Ti24 1 Local closing control on rising edge and opening control on falling edge Y1 Local one shot closing and opening control Y2 Centralized closing control on rising edge and opening con...

Страница 23: ...ircuit breaker switches to closed position z When input Y1 changes to 0 the Reflex iC60 circuit breaker switches to Ready position contacts open z A pulse on input Y2 makes the Reflex iC60 circuit bre...

Страница 24: ...gram shows mode 2 operation of versions with Ti24 interface Operation is as follows z A rising edge on input Y1 makes the Reflex iC60 circuit breaker switch to Ready position contacts open z The state...

Страница 25: ...are ineffective z On input Y3 in this case controls on input Y2 are ineffective Mode 3 is used for centralized opening closing of the circuit breaker and local override z local control selector Y1 0...

Страница 26: ...0 the Reflex iC60 circuit breaker switches to Ready position contacts open Connection diagram 2 The following connection diagram enables the Reflex iC60 circuit breaker to optionally use depending on...

Страница 27: ...ational When input Y3 Ti24 changes to 1 the Reflex iC60 circuit breaker switches to closed position When input Y3 Ti24 changes to 0 the Reflex iC60 circuit breaker switches to Ready position contacts...

Страница 28: ...LED indicates the operating mode z Mode 1 the LED flashes once green z Mode 2 the LED flashes twice green z Mode 3 the LED flashes three times green NOTE Selection of the operating mode is described...

Страница 29: ...t auto OFF 5 6 Mode 1 Mode 2 Mode 3 Ti24 auto OFF auto OFF 3 4 YES NO Mode OK auto OFF Mode 3 x 1 x 1 x 1 2 1 4 1 u 3 s 4 2 Ti24 Reflex iC60N Ready Mode1 2 3 I ON O OFF Overheat Reflex iC60N Ready Mod...

Страница 30: ...with Ti24 interface 4 Press the pushbutton several times in succession to select the required operating mode Each press switches the circuit breaker from one mode to the next 5 Once the operating mode...

Страница 31: ...60 integrated control circuit breaker is likely to switch to automatic overheat protection for a period of 5 to 25 seconds Activation of Overheat Protection During normal operation of the Reflex iC60...

Страница 32: ...breaker is open or tripped No control locally by means of the pushbutton or Y1 Y2 Y3 is possible The following actions are necessary in order to control the circuit breaker z If the circuit breaker i...

Страница 33: ...tripping caused by a fault in the power circuit downstream of the Reflex iC60 circuit breaker 1 0 The poles are welded This is shown by the absence of the green line which indicates the position of t...

Страница 34: ...ep Action 1 Pull out the padlocking device from the Reflex iC60 integrated control circuit breaker 2 Attach the padlock diameter 3 to 6 mm to the padlocking device 3 On 3P 4P circuit breaker models at...

Страница 35: ...grated Control Circuit Breaker Application examples A9MA03EN 02 2012 Application examples What s in this Chapter This chapter contains the following topics Topic Page Outdoor parking lot lighting 36 O...

Страница 36: ...A multifunction time switch combined with a light sensitive switch sends opening or closing commands to each circuit breaker via input Y1 according to the time slots corresponding to the periods when...

Страница 37: ...e circuit breaker is open and the controls on input Y2 are inhibited When input Y1 is at low state the circuit breaker is controlled by input Y2 z Pushbuttons are used to control the office lighting l...

Страница 38: ...are controlled by Reflex iC60 circuit breakers connected to a PLC via the Ti24 interface and set to mode 3 In this mode input Y1 is used to choose between local mode Y1 0 and centralized mode Y1 1 In...

Страница 39: ...N P N P 24 V c 0 V Ti24 Y1 Y2 1 Manual Auto 2 4 Supervisory control system N P 24 V 0 V Outputs Inputs 24 V Y3 0 V O C Q3 Reflex iC60 Mode 3 Floor 1 lighting Floor 2 lighting 24 V c 0 V ISSW1 1 ISSW2...

Страница 40: ...Application examples 40 A9MA03EN 02 2012...

Страница 41: ...4 11 class III Immunity to power supply frequency variation IEC 61 000 4 28 and IACS E10 Harmonic resistance IEC 61 000 4 13 class 2 Immunity to electrostatic discharge air 8 kV IEC 61 000 4 2 contact...

Страница 42: ...y Minimum duration of control pulse for input Y2 200 ms Maximum response time of input Y2 250 ms Inrush currents for 230 V AC 50 Hz control 2P 4 2 A peak 3P 8 2 A peak 4P 16 2 A peak Consumption 1 W I...

Страница 43: ......

Страница 44: ...e from time to time please ask for confirmation of the information given in this publication A9MA03EN 01 A9MA03EN 01 Schneider Electric Industries SAS 35 rue Joseph Monier CS30323 F 92506 Rueil Malmai...

Отзывы: