VISION VXL

  

 

 

8540615 • 19/12/2014 • Rev.8 

 

 

VERTICAL POSITION OF THE BARRIER 

 

30 mm and 40 mm resolution models. 

 

These models are suitable for the protection of  
hands. 

 

The  minimum  safety  distance 

S

  is  calculated 

according to the following formula: 

S = 2000(t

1

 + t

2

) + 8(D-14) 

(D=resolution) 

 

This  formula  is  valid  for  distances 

S

  between  100 

and  500  mm.  If  this  formula  results  in 

S

  being 

greater  than  500  mm,  the  distance  can  be  reduced 
to a minimum of 500 mm by means of the following 
formula: 

S = 1600(t

1

 + t

2

) + 8(D-14) 

If,  due  to  the  specific  configuration  of  the  machine, 
the  dangerous  area  can  be  accessed  from  above, 
the highest beam of the barrier must be at a height 

H

  of  at  least  1800  mm  from  the  base 

G

 

of  the 

machine.  
 

 
 
 
 
 
 
 

 

Figure 4 

 

 

 

Multibeam Models.

 

 

These models are  suitable for the protection of  
the entire body and must not be used to protect 
arms or legs. 

 
The  minimum  safety  distance 

S

  is  calculated 

according to the following formula: 

S = 1600 (t

1

 + t

2

) + 850 

 

 

The reccomended height 

H

 from the base 

(G) must be the following: 
 

 

 

Figure 5 

  MODEL 

BEAMS 

Reccomended Height H (mm) 

 

 

VXL 2B 
VXL 3B 
VXL 4B 



400 

 900 

300 

 700 

 1100 

300 

 600 

 900 - 1200 

 
 

safety 
barrier 

point of 
danger 

direction 
of 
approach 

reference plane 

safety barrier 

point of 
danger 

direction 
of 
approach 

reference plane 

Содержание VISION VXL

Страница 1: ...CTION CABLES 10 EXAMPLE OF CONNECTION WITH AD SR0 WITH START RESTART INTERLOCK ACTIVATED 12 CONFIGURATION AND OPERATION MODES 12 K1 K2 EXTERNAL CONTACTORS CONNECTION 13 MULTIPLE SYSTEMS 13 USE OF DEFL...

Страница 2: ...rier system features an automatic self diagnosis function that enables it to detect every malfunctions in an maximum execution time of 0 5 sec This safety system is permanently active and does not req...

Страница 3: ...gure 1 The resolution is constant irrespectively of work conditions as it only depends on the geometric characteristics of the lenses and the distance between the centres of two adjacent lenses The he...

Страница 4: ...width and height of the relative access area to be calculated Compare these dimensions with the maximum working range and the height of the protected area in relation to the specific model The general...

Страница 5: ...must be taken in order to prevent the formation of condensation on the lenses which could have an adverse effect on monitoring POSITION The position of the VXLE Emitter and the VXLR Receiver must pre...

Страница 6: ...proach speed of object to the dangerous area mm sec t1 response time of the safety barrier in seconds sec t2 machine response time in seconds meaning the time required for the machine to interrupt the...

Страница 7: ...figuration of the machine the dangerous area can be accessed from above the highest beam of the barrier must be at a height H of at least 1800 mm from the base G of the machine Figure 4 Multibeam Mode...

Страница 8: ...between the outer limit of the dangerous area and the most external optical beam is greater than or equal to the minimum safety distance S calculated as follows S 1600 t1 t2 1200 0 4H where H is the...

Страница 9: ...trical connections must be made according to the diagrams in this manual In particular do not connect other devices to the connectors of the Emitter and Receiver For reliability of operation when a di...

Страница 10: ...131 2 ref Par Configuration and operation modes 6 Pink SEL_B INPUT 4 Yellow K1_K2 INPUT External contactors Feedback Table 2 WARNINGS REGARDING THE CONNECTION CABLES For connections over 50m long use...

Страница 11: ...e of connection in MANUAL mode with external contactors K1 K2 Figure 7 Example of connection in AUTOMATIC mode with external contactors K1 K2 Figure 8 If the TEST function is not required by the appli...

Страница 12: ...ease consider the risk analysis of your application about this matter In AUTOMATIC functioning the two static outputs OSSD1 and OSSD2 follow the status of the guarded opening with the area guarded cle...

Страница 13: ...ERATION MODE SEL_A PIN 5 connected to 24VDC PIN 2 SEL_B PIN 6 connected to 24VDC PIN 2 through the RESTART pushbutton K1_K2 PIN 4 connected to 0VDC MANUAL without K1 K2 feedback control SEL_A PIN 5 co...

Страница 14: ...L 14 8540615 19 12 2014 Rev 8 Figure 9 Systems installed alongside each other A Installation of two adjacent Emitters Overlapping systems B L shaped installation C Crossed positioning of Emitters and...

Страница 15: ...vide a U shaped protection Figure 10 The following rules should be taken into consideration when using deviation mirrors Place the mirrors so as to ensure compliance with the minimum safety distance S...

Страница 16: ...flecting surfaces and the protected area The minimum distance d must be calculated according to the distance l between the Emitter and the Receiver considering that the angle of projection and recepti...

Страница 17: ...and Receiver facilitate this operation To perform an easier alignment the use of SFB circular brackets is necessary These are available on request ordering code 1330974 Figure 13 Position the optical...

Страница 18: ...ver units labels are visualized depending on the system operation phase The tables below shows the different signals ref Figure 14 EMITTER RECEIVER Figure 14 EMITTER SIGNALS Normal operation MEANING R...

Страница 19: ...ack enabled OFF ON blinking every 1 2sec ON BREAK condition A ON OFF OFF OFF CLEAR condition B ON OFF ON OFF GUARD Condition C OFF ON OFF OFF A Barrier occupied output disabled B Barrier free output d...

Страница 20: ...out a periodical system test As decribed above the VISION VXL barrier features an automatic self diagnosis function which is permanently active and verify the entire VXL operation with a periodic auto...

Страница 21: ...4 Response time ms 7 11 5 16 20 24 28 5 33 37 Overall barrier ht mm 261 411 561 711 861 1011 1161 1311 PFHd 2 44E 08 3 56E 08 4 68E 08 5 8E 08 6 92E 08 8 05E 08 9 17E 08 1 03E 07 DCavg 94 0 93 7 93 6...

Страница 22: ...551 701 851 1001 1151 1301 1451 1601 1751 1901 B protected area 160 310 460 610 760 910 1060 1210 1360 1510 1660 1810 C 85 Fastening 2 LS Brackets with 2 mounting inserts 3 LS Brackets with 3 mounting...

Страница 23: ...gure 18 LL and LH TYPE fastening brackets optional Figure 19 Fastening brackets for deviation mirrors Figure 20 Deviation mirrors Model H SP100S 250 SP300S 400 SP400S 540 SP600S 715 SP700S 885 SP900S...

Страница 24: ...Make sure that during each stage of the test object s movements the red LED on the Receiver is always on Figure 21 The VISION VXL barrier does not require any specific maintenance operations however p...

Страница 25: ...eeR laboratories OSSD static outputs error ON OFF OFF 2 consecutive pulses Carefully check the connection of terminals 1 and 3 OSSD on the connector If necessary adjust load reducing the current requi...

Страница 26: ...comply with those specified in the technical data sheet the barrier power supply should be kept separate from that of the other electric power equipment electric motors inverters frequency converters...

Страница 27: ...2 C8D95 90 8 pin M12 female connector 5 m cable 1330983 C8D910 90 8 pin M12 female connector 10 m cable 1330984 C8D915 90 8 pin M12 female connector 15 m cable 1330985 C8DM9 Straight 8 pin M12 female...

Страница 28: ...onnel not authorised by ReeR tampering etc Accidents or collisions also during transportation or due to acts of God Other reasons for which ReeR cannot be held responsible Repairs will be carried out...

Отзывы: