VISION VXL
8540615 • 19/12/2014 • Rev.8
19
RECEIVER SIGNALS
Normal operation
MEANING
LED
RED (5)
GREEN (7)
(CLEAR)
YELLOW (4)
(OSSD)
RED (6)
System power on. Initial TEST
ON
OFF
ON
ON
Light-on for 10sec: Manual
with feedback disabled
OFF
ON
blinking every
2sec
OFF
Light-on for 10sec: Manual
with feedback enabled
OFF
ON
blinking every
1/2sec
OFF
Light-on for 10sec: Automatic
with feedback disabled
OFF
ON
blinking every
2sec
ON
Light-on for 10sec: Automatic
with feedback enabled
OFF
ON
blinking every
1/2sec
ON
BREAK
condition
(A)
ON
OFF
OFF
OFF
CLEAR
condition
(B)
ON
OFF
ON
OFF
GUARD
Condition
(C)
OFF
ON
OFF
OFF
(A) Barrier occupied - output disabled
(B) Barrier free - output disabled - Waiting for restart
(C) Barrier free - output enabled
Configuration errors
MEANING
LED
RED (5)
GREEN
(7)
(CLEAR)
YELLOW (4)
(OSSD)
RED (6)
Customer configuration rejected
ON
OFF
4 consecutive
pulses
OFF
OSSD erroneously connected to 24VDC
ON
OFF
OFF
5 consecutive
pulses
External Feedback contactors missed
ON
OFF
5 consecutive
pulses
OFF
On the emitter of the
Multibeam
models, near each beam, is present a red led
which permits an easy detection of the beam.