12
8540581 - 29/09/2010 - Rev.10
SLAVE MODELS - M12, 5-pin connector
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC
-
+24 VDC power supply
-
3
Blue
0VDC
-
0 VDC power supply
-
5
Grey
PE - Ground
connection
-
2
White
OSSD1 OUTPUT
4
Black
OSSD2 OUTPUT
Safety static outputs
PNP active high
Table 4
MASTER MODELS (SECONDARY CONNECTOR) - 5 poles M12.
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC
-
+24 VDC power supply
-
3
Blue
0VDC
-
0 VDC power supply
-
5
Grey
PE - Ground
connection
-
2
White
SLAVE1 INPUT
4
Black
SLAVE2 INPUT
Slave OSSD outputs
readout
According the standard
EN61131-2
(PNP active high)
Table 5
RECEIVER
MASTER MODELS (PRIMARY CONNECTOR) - STANDARD MODELS
MASTER MODELS (PRIMARY CONNECTOR) - 8 poles M12.
STANDARD MODELS - 8 poles M12 connector.
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
2
Brown
24VDC
-
+24 VDC power supply
-
7
Blue
0VDC
-
0 VDC power supply
-
8
Red
PE - Ground
connection
-
1
White
OSSD1 OUTPUT
3
Green
OSSD2 OUTPUT
Safety static outputs
PNP active high
5
Grey
SEL_A INPUT
6
Pink
SEL_B INPUT
4
Yellow
SEL_C INPUT
Barrier configuration
According the standard EN61131-2
(ref. Par. "Configuration and operation
modes")
Table 6
WARNINGS REGARDING THE CONNECTION CABLES
•
For connections over 50 m long, use cables with a cross-section area
of 1 mm
2
.
•
The power supply to the barrier should be kept separate from that to other
electric power equipment (electric motors, inverters, frequency converters) or
other sources of disturbance.
•
Connect the Emitter and the Receiver to the ground outlet.
•
The connection cables must follow a different route to that of the other power
cables.