In the lower right corner of the screen you can find the device calibration function. Proper
calibration is very important, because it influences the dosing precision. The device should
be calibrated according to the prompt. The calibration process makes it possible to
automatically fill the hoses with liquid ("FILL THE CIRCUIT" button) and set the amount of
liquid poured into your tank in a specified time frame ("BEGIN CALIBRATION" button).
9.
The device should be calibrated right after the set up procedure, so that the dosing process
is carried out appropriately and the pump is able to correctly indicate the amount of liquid
poured to the tank. Before starting the calibration procedure, prepare a container for the liquid
poured during the process. During calibration, the device activates the pump for 30 seconds
and then automatically deactivates it.
10.
Next, you will have to check the amount of liquid poured into the prepared container (in
milliliters).
11.
In the next step enter the time after which the device should remind you to recalibrate the
device. You will receive a reminder in the form of a
Smart Reef
system notification.