reedinstruments
www
com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Basic Settings
Please refer to the Menu arrangement. Press the Red Bar Button to enter
the Menu. Press the Up and Down Buttons to scroll through the Menu.
Press the Red Bar Button for OK/Yes/Menu/Select functions, and the Blue
Bar Button for Esc/No/Back functions.
Measuring Modes
Continuous Mode
: In Continuous Mode, the probe is not lifted off the
surface being measured. Readings are not
accompanied by a beep. All readings taken in this
mode are automatically entered into the statistics
program as long as sufficient memory is available.
Single Mode
:
In Single Mode, the probe is lifted off the surface
being measured and moved. Readings are
accompanied by a beep. All readings taken in this
mode are automatically entered into the statistics
program as long as sufficient memory is available.
Probe Operating
The probe can work in three modes:
AUTO
: The probe can automatically select the working mode. When
placed on steel (magnetic substrates), it will work in magnetic
induction principle. When placed on no-ferrous metals, it will work
in eddy current principle.
Fe:
The probe works in magnetic induction principle.
No-Fe
: The probe works in eddy current principle.
Unit Settings
You can switch from Metric units (um, mm) to Imperial (mils) units. In “um”
mode, the unit will switch to “mm” automatically when value of reading
exceeds 850um. See the Specification section for more details.
www.reedinstruments.com
1-877-849-2127 | [email protected]