REED SD-8205 Скачать руководство пользователя страница 9

reedinstruments

www

com

9

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

INSTRUMENTS

tion is being saved in memory.  
 
To set the sampling time, and to toggle the beeper sound on or off, 
refer to the Advanced Settings section of this manual.

2)  Pause the Datalogging; while Datalogging, if press the Logger But-

ton once. While paused, the “REC” symbol will stop flashing. Press 
the Logger Button again to resume Datalogging, and the “REC” 
symbol will begin to flash again.

3)  Stop Datalogging; while the Datalogger function is paused, press 

the REC Button for 2 seconds. The “REC” symbol will disappear 
indicating the Datalogging function has stopped. 

Manual Datalogger (Set sampling time = 0 seconds)

1)  Set sampling time is to 0 second; Press the REC Button, and the 

“REC” symbol will appear on the LCD screen. Press the Logger 
Button, and the “REC” symbol will flash once and one Beep will 
sound, at the same time the measuring data along the time infor-
mation will be saved in memory. The lower Display will show the 
Position (record) number, which is saved as well. 

2)  To Change the Position Number; press the Down Button and the 

lower position number will flash on the display. Press the Up or 
Down Buttons to set the Position Number (1 to 99) to help identify 
the measurement location. The lower Display will show P x (x = 1 to 
99). After the position number is selected, press the Enter Button to 
confirm.

3)  Stop Datalogging; press the REC Button for 2 seconds, and the 

“REC” symbol will disappear indicating the Datalogging function 
has stopped. 

Checking the Time

During normal functions (not Datalogging), press the Time Check Button 
and the lower LCD display will show the Year, Month/Date, Hour/Minute.

Check Sampling Time Information 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание SD-8205

Страница 1: ...20 20 20 100 Only if you REALLY need them Model Vibration Meter Datalogger SD 8205 reedinstruments www com Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTest...

Страница 2: ...t 7 Max hold reset procedures 7 Data Hold 7 Data Record 7 8 Backlight ON OFF 8 Datalogger 8 Auto Datalogger 8 9 Manual Datalogger 9 Checking the Time 9 Check Sampling Time Information 9 SD Card Data S...

Страница 3: ...No extra software needed just plug the SD card into the computer and it downloads directly to EXCEL SD card capacity 1 GB to 16 GB Easy to read LCD with backlight Auto power off or manual power off D...

Страница 4: ...case and batteries Optional accessories 4G SD Card SD 4GD External Probe SD 8205PROBE USB cable USB 01 Power adapter AP 9VA 110V Data Acquisition Software SW U801 WIN Tripod BS 6 Visit us at www reedi...

Страница 5: ...er ESC Backlight Button 3 Hold Function Next Button 4 REC Enter Unit Button 5 SET Down Time Check Button 6 Logger Up Sampling Time Check Zero Max Button 7 BNC input socket 8 SD card slot 9 USB RS232 O...

Страница 6: ...h the Sensor Cable when taking measurements Changing Unit To change the measuring unit press and hold the Unit Button The display will flash the units m s2 g mm s cm s ft s2 inch s Release the Unit Bu...

Страница 7: ...s and hold the Logger Button for at least 5 seconds to clear the existing Max hold value Data Hold While taking a measurement press the Hold Button once and the mea sured value will hold on the screen...

Страница 8: ...nsert the optional SD card into the SD card socket 2 Before you use an SD card with this meter for the first time it is recommend to format the SD card See Advanced Settings section of this manual for...

Страница 9: ...d Press the REC Button and the REC symbol will appear on the LCD screen Press the Logger Button and the REC symbol will flash once and one Beep will sound at the same time the measuring data along the...

Страница 10: ...1 can hold 99 XLS files When that number has been reached the meter will then will generate a new folder with a subsequent number for example VBA02 Max number of VBA folders is 10 Data Transfer from S...

Страница 11: ...ing function press the Esc Button to exit and to return to normal functioning Set Clock Time 1 When the lower display shows dAtE press the Enter Button Use the Up and Down Buttons to adjust the Year A...

Страница 12: ...yES Beeper Sound is ON or no Beeper Sound is OFF 2 After selecting yES or no press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button Set sampling time...

Страница 13: ...5 mm terminal The connector output is a 16 digit data stream which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the inst...

Страница 14: ...rt Word System Reset If an error occurs press the Reset Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstrumen...

Страница 15: ...act REED Instruments at info reedinstruments com Notes __________________________________________ ________________________________________________ ________________________________________________ ____...

Страница 16: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Отзывы: