REED GM-600G Скачать руководство пользователя страница 9

Gross Weight, Net Weight

After the display show " TARE " indicator ( If the first
load weight value is   20 gram ).

* Push and release the " N/G Button ( Net/Gross Weight

Button ) " ( 3-2, Fig. 1 ) will show the gross weight
value ( the first load weight value + second load
weight value ), the " TARE " indicator will be
disappeared.

* Push and release the " N/G Button " ( 3-2, Fig. 1 )

again, will return to show the net weight value ( the
second load weight value ), the " TARE " indicator
will show on LCD  again.

6)Counting Scale

a. Press the " MODE Button " ( 3-5, Fig. 1 ) once

until the indicator show to the " PCS "

b. Press the " N/G Button " ( 3-2, Fig. 1 ) once

can select the counting sample no. ( S=10,
S=20, S=50, S=100 ).

c. After the counting sample no. be selected ( for example

 S=20 ), then put the samples ( for example 20 PCs )
on the platform.
Press the " MODE Button " ( 3-5, Fig. 1 ) once, the
display will show " CAL " then return to counting no.,
now the  scale is ready for the counting measurement.

5. BATTERY REPLACEMENT

If battery is weak, LCD display will show "           " indicator.
This reminds user to replace new battery.

7

Содержание GM-600G

Страница 1: ...SCALE marks a step forward for you into the field of precision measurement Although this DIGITAL SCALE is a complex and delicate instrument its durable structure developed Please read the following i...

Страница 2: ...N G Button Net Gross Weight Button 4 3 3 TARE Button 4 3 4 Power Button 4 3 5 MODE Button 4 3 6 Platform 4 3 7 Power Slide Switch 4 3 8 DC 9V receptacle 4 3 9 Battery Cover Compartment 4 4 MEASURING P...

Страница 3: ...ay With counting scale function Digital display easy measurement Back light LCD display Gram pound display unit Auto power off Auto calibration capability Durable portable housing plastic case LOAD CE...

Страница 4: ...ct g or oz Function Weight scale Counting scale Sampling Time Approx 0 8 second Tare Control Full capacity Transducer Load cell Circuit Exclusive LSI circuit Over Load Show EEEEE Indicator Cabinet Siz...

Страница 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3...

Страница 6: ...Fig 1 3 1 Display 3 2 N G Button Net Gross Weight Button 3 3 TARE Button 3 4 Power Button 3 5 MODE Button 3 6 Platform 3 7 Power Slide Switch 3 8 DC 9V receptacle 3 9 Battery Cover Compartment 4...

Страница 7: ...ng the environment satiability before the operation it should let the scale stay the measurement environment at least 10 minutes 2 a If intend to measure the weight of small particle or liquid then it...

Страница 8: ...sh the first load weight measurement push the Tare Button 3 3 Fig 1 and release the display will show Zero weight value If the first load weight value is 20 gram after push the TARE Button LCD will sh...

Страница 9: ...value the TARE indicator will show on LCD again 6 Counting Scale a Press the MODE Button 3 5 Fig 1 once until the indicator show to the PCS b Press the N G Button 3 2 Fig 1 once can select the countin...

Страница 10: ...receptacle 3 8 Fig 1 3 Now the scale is ready for ACV operation 7 CALIBRATION PROCEDURES 1 Set the Power Slide Switch 3 7 Fig 1 to the ON position 2 Let the scale not power ON LCD is not light Press t...

Отзывы: