2. SPECIFICATIONS

Display

5 digits w/annunciator.
15 mm ( 0.59 mm ) digit height.

Measuring 

600 g/21.12 oz.

Capacity
Resolution

0.1 g/0.005 oz.

Min. Display 

0.3 g/0.015 oz.

Weight
Accuracy

± ( 0.1 % + 2 d ) 

* After the calibration.

Unit  Select

g or oz.

Function

Weight scale, Counting scale.

Sampling  Time

Approx. 0.8 second.

Tare  Control

Full capacity.

Transducer

Load cell.

Circuit

Exclusive LSI-circuit.

Over Load 

Show " EEEEE ".

Indicator
Cabinet  Size

150  x  145  x  48  mm
 ( 5.9 x 5.7 x 1.9 inch )

Platform  Size

195 x 150 mm.
 ( 7.7 x 5.9 inch )

Power  Supply

6 x 1.5V AA (UM-3) batteries,
or DC 9V adapter.

Power 

Approx. DC 15 mA.

Consumption
Accessory 

Operation manual................1 PC.

Included

2

Содержание GM-600G

Страница 1: ...SCALE marks a step forward for you into the field of precision measurement Although this DIGITAL SCALE is a complex and delicate instrument its durable structure developed Please read the following i...

Страница 2: ...N G Button Net Gross Weight Button 4 3 3 TARE Button 4 3 4 Power Button 4 3 5 MODE Button 4 3 6 Platform 4 3 7 Power Slide Switch 4 3 8 DC 9V receptacle 4 3 9 Battery Cover Compartment 4 4 MEASURING P...

Страница 3: ...ay With counting scale function Digital display easy measurement Back light LCD display Gram pound display unit Auto power off Auto calibration capability Durable portable housing plastic case LOAD CE...

Страница 4: ...ct g or oz Function Weight scale Counting scale Sampling Time Approx 0 8 second Tare Control Full capacity Transducer Load cell Circuit Exclusive LSI circuit Over Load Show EEEEE Indicator Cabinet Siz...

Страница 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3...

Страница 6: ...Fig 1 3 1 Display 3 2 N G Button Net Gross Weight Button 3 3 TARE Button 3 4 Power Button 3 5 MODE Button 3 6 Platform 3 7 Power Slide Switch 3 8 DC 9V receptacle 3 9 Battery Cover Compartment 4...

Страница 7: ...ng the environment satiability before the operation it should let the scale stay the measurement environment at least 10 minutes 2 a If intend to measure the weight of small particle or liquid then it...

Страница 8: ...sh the first load weight measurement push the Tare Button 3 3 Fig 1 and release the display will show Zero weight value If the first load weight value is 20 gram after push the TARE Button LCD will sh...

Страница 9: ...value the TARE indicator will show on LCD again 6 Counting Scale a Press the MODE Button 3 5 Fig 1 once until the indicator show to the PCS b Press the N G Button 3 2 Fig 1 once can select the countin...

Страница 10: ...receptacle 3 8 Fig 1 3 Now the scale is ready for ACV operation 7 CALIBRATION PROCEDURES 1 Set the Power Slide Switch 3 7 Fig 1 to the ON position 2 Let the scale not power ON LCD is not light Press t...

Отзывы: