Product Warranty

REED Instruments guarantees this instrument to be free of defects in 
material or workmanship for a period of one (1) year from date of shipment. 
During the warranty period, REED Instruments will repair or replace, at no 
charge, products or parts of a product that proves to be defective because 
of improper material or workmanship, under normal use and maintenance. 
REED Instruments total liability is limited to repair or replacement of the 
product. REED Instruments shall not be liable for damages to goods, 
property, or persons due to improper use or through attempts to utilize 
the instrument under conditions which exceed the designed capabilities. 
In order to begin the warranty service process, please contact us by email 
at 1-877-849-2127 or [email protected] to discuss the claim and 
determine the appropriate steps to process the warranty.

Product Disposal and Recycling

Please follow local laws and regulations when disposing or recycling your 

instrument. Your product contains electronic components and must be 

disposed of separately from standard waste products.

Product Support 

If you have any questions on your product, please contact your authorized 
REED distributor or REED Instruments Customer Service by phone at 
1-877-849-2127 or by email at [email protected].

Please visit 

www.REEDINSTRUMENTS.com

 for the most  

up-to-date manuals, datasheets, product guides and software.

Product specifications subject to change without notice.  

All rights reserved. Any unauthorized copying or reproduction of  

this manual is strictly prohibited without prior written permission  

from REED Instruments.

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R4000SD

Страница 1: ...Data Logging Vane Thermo Anemometer Instruction Manual R4000SD REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...10 Data Hold 11 Recording Maximum and Minimum Readings 11 Backlight 11 Setup Mode 12 15 Setting the Time and Date dAtE 12 Setting Data Decimal Format dEC 13 Enabling Disabling Auto Power Off PoFF 13...

Страница 3: ...rchasing your REED R4000SD Data Logging Vane Thermo Anemometer Please read the following instructions carefully before using your instrument By following the steps outlined in this manual your meter w...

Страница 4: ...asurement with type J K thermocouple option Thermistor sensor for fast air temperature readings Low friction ball bearing rotating vane probe ensures high accuracy readings Real time data logger with...

Страница 5: ...8 km h 0 4 mph 0 4 knot Air Temperature 1 5 F 0 8 C Temperature 58 F 50 C 0 4 1 F 0 5 C 58 F 50 C 0 4 1 8 F 1 C Resolution fpm 1 m s km h mph knot 0 1 Temperature 0 1 F C Vane Diameter 2 8 72mm Respon...

Страница 6: ...es Power Supply 6 x AA batteries or AC Adapter optional Data Output Yes RS 232 Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140 F 10 to 60 C Operatin...

Страница 7: ...ton 3 SET Down Time Check Button 4 SD Card Slot 5 HOLD FUNCTION NEXT Button 6 REC ENTER Button 7 LOG Up Sampling Check Button 8 RS 232 Output Jack 9 Reset Pin 10 Power Adapter Input 11 Tripod Mounting...

Страница 8: ...Time Values Measurement Modes Indicator 3 Date Time Stamp 4 Temperature Unit of Measure 5 Units of Measure 6 Maximum and Minimum Indicators 7 Record Mode Indicator 8 Data Hold Indicator 9 Low Battery...

Страница 9: ...ure and tP for Type K J Thermometer measurement modes of operation 2 Release the FUNCTION button to confirm selection Air Velocity Temperature Measurement 1 Plug the rotating vane into the Probe Input...

Страница 10: ...on see Selecting Measurement Modes for details 2 Plug the optional Type K or J Thermocouple Probe into the Type K J thermocouple input jack Note Make sure to remove the rotating vane before inserting...

Страница 11: ...and minimum readings 2 While in recording mode A Press the REC button once and the maximum value will appear on the display as indicated by REC MAX B Press the REC button again and the minimum value...

Страница 12: ...eter will automatically exit out of the Setup mode if no key is pressed within 7 seconds Setting the Time and Date dAtE 1 Press the ENTER button when dAtE appears on the LCD 2 Press the and buttons to...

Страница 13: ...n PoFF appears on the LCD 1 Press the and buttons to select between ON enabled or OFF disabled With the Auto Power OFF feature enabled the meter will automatically switch OFF after 10 minutes of inact...

Страница 14: ...e and buttons to to adjust the sampling rate between 0 1 2 5 10 30 60 120 300 600 1800 and 3600 seconds 2 Press the ENTER button to confirm selection and skip to next parameter Note At any time you ca...

Страница 15: ...r The card must be inserted with the label side facing the rear of the meter Manual Data Logging Mode In manual mode the LOG button is pressed to manually log a reading on the inserted SD card at any...

Страница 16: ...ough 5 below 1 To begin a data logging session press the REC button and REC will appear on the LCD 2 Press the LOG button The meter will scan for a SD memory card Note If a card is not inserted or the...

Страница 17: ...15 m S 30 AMTemp C 7 07 10 19 8 14 18 0 3 m S 21 6 AMTemp C 8 07 10 19 8 14 20 0 1 m S 21 6 AMTemp C 9 07 10 19 8 14 22 15 m S 25 AMTemp C 10 07 10 19 8 14 24 1 1 m S 21 4 AMTemp C 11 07 10 19 8 14 2...

Страница 18: ...Stop bits 1 41110000000335 Upper Value 335 FPM Reading Decimal Place 0 3 Positive 0 Negative 1 C 01 F 02 m s 08 Knot 09 Km h 10 FPM 11 mph 12 1 Upper display value 2 Lower display value 4 410101000002...

Страница 19: ...batteries must be replaced 1 Remove the two 2 Phillips screws on the back of the meter directly located above the top of the kickstand 2 Remove the battery cover 3 Replace 6 x AA batteries 4 Secure t...

Страница 20: ...for Battery life will depend on a number of factors Quality of Battery Whether the beeper is ON or OFF Whether the backlight is ON or OFF Environmental Conditions during data logging As a reference us...

Страница 21: ...2127 or info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposin...

Страница 22: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Отзывы: