background image

13

Setting Data Decimal Format (dEC)

Numeric formats vary in different countries. By default the meter is set 
to bASIC mode where a decimal point is used to separate units, (i.e. 
20.00). The European format uses a comma (i.e. 20,00) to separate units. 
To change this setting, follow steps 1 and 2 when the "dEC" parameter 
appears on the LCD.
1.  Press the   and   buttons to select between bASIC and Euro.
2.  Press the 

ENTER

 button to confirm selection and skip to 

next parameter.

Note

: At any time, you can press the 

ESC

 button to exit the Setup mode 

and resume normal operation.

Enabling/Disabling Auto Power Off (PoFF)

Follow steps 1 and 2 when "PoFF" appears on the LCD.
1.  Press the   and   buttons to select between ON (enabled) or OFF 

(disabled). With the Auto Power OFF feature enabled, the meter will 
automatically switch OFF after 10 minutes of inactivity to preserve 
battery life.

2.  Press the 

ENTER

 button to confirm selection and skip to 

next parameter.

Note

: At any time, you can press the 

ESC

 button to exit the Setup mode 

and resume normal operation.

Enabling/Disabling the Beeper (bEEP)

Follow steps 1 and 2 when "bEEP" appears on the LCD.
1. 

Press the   and   buttons to select between ON (enabled) or 
OFF (disabled).

2.  Press the 

ENTER

 button to confirm selection and skip to 

next parameter.

Note

: At any time, you can press the 

ESC

 button to exit the Setup mode 

and resume normal operation.

continued...

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R4000SD

Страница 1: ...Data Logging Vane Thermo Anemometer Instruction Manual R4000SD REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...10 Data Hold 11 Recording Maximum and Minimum Readings 11 Backlight 11 Setup Mode 12 15 Setting the Time and Date dAtE 12 Setting Data Decimal Format dEC 13 Enabling Disabling Auto Power Off PoFF 13...

Страница 3: ...rchasing your REED R4000SD Data Logging Vane Thermo Anemometer Please read the following instructions carefully before using your instrument By following the steps outlined in this manual your meter w...

Страница 4: ...asurement with type J K thermocouple option Thermistor sensor for fast air temperature readings Low friction ball bearing rotating vane probe ensures high accuracy readings Real time data logger with...

Страница 5: ...8 km h 0 4 mph 0 4 knot Air Temperature 1 5 F 0 8 C Temperature 58 F 50 C 0 4 1 F 0 5 C 58 F 50 C 0 4 1 8 F 1 C Resolution fpm 1 m s km h mph knot 0 1 Temperature 0 1 F C Vane Diameter 2 8 72mm Respon...

Страница 6: ...es Power Supply 6 x AA batteries or AC Adapter optional Data Output Yes RS 232 Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140 F 10 to 60 C Operatin...

Страница 7: ...ton 3 SET Down Time Check Button 4 SD Card Slot 5 HOLD FUNCTION NEXT Button 6 REC ENTER Button 7 LOG Up Sampling Check Button 8 RS 232 Output Jack 9 Reset Pin 10 Power Adapter Input 11 Tripod Mounting...

Страница 8: ...Time Values Measurement Modes Indicator 3 Date Time Stamp 4 Temperature Unit of Measure 5 Units of Measure 6 Maximum and Minimum Indicators 7 Record Mode Indicator 8 Data Hold Indicator 9 Low Battery...

Страница 9: ...ure and tP for Type K J Thermometer measurement modes of operation 2 Release the FUNCTION button to confirm selection Air Velocity Temperature Measurement 1 Plug the rotating vane into the Probe Input...

Страница 10: ...on see Selecting Measurement Modes for details 2 Plug the optional Type K or J Thermocouple Probe into the Type K J thermocouple input jack Note Make sure to remove the rotating vane before inserting...

Страница 11: ...and minimum readings 2 While in recording mode A Press the REC button once and the maximum value will appear on the display as indicated by REC MAX B Press the REC button again and the minimum value...

Страница 12: ...eter will automatically exit out of the Setup mode if no key is pressed within 7 seconds Setting the Time and Date dAtE 1 Press the ENTER button when dAtE appears on the LCD 2 Press the and buttons to...

Страница 13: ...n PoFF appears on the LCD 1 Press the and buttons to select between ON enabled or OFF disabled With the Auto Power OFF feature enabled the meter will automatically switch OFF after 10 minutes of inact...

Страница 14: ...e and buttons to to adjust the sampling rate between 0 1 2 5 10 30 60 120 300 600 1800 and 3600 seconds 2 Press the ENTER button to confirm selection and skip to next parameter Note At any time you ca...

Страница 15: ...r The card must be inserted with the label side facing the rear of the meter Manual Data Logging Mode In manual mode the LOG button is pressed to manually log a reading on the inserted SD card at any...

Страница 16: ...ough 5 below 1 To begin a data logging session press the REC button and REC will appear on the LCD 2 Press the LOG button The meter will scan for a SD memory card Note If a card is not inserted or the...

Страница 17: ...15 m S 30 AMTemp C 7 07 10 19 8 14 18 0 3 m S 21 6 AMTemp C 8 07 10 19 8 14 20 0 1 m S 21 6 AMTemp C 9 07 10 19 8 14 22 15 m S 25 AMTemp C 10 07 10 19 8 14 24 1 1 m S 21 4 AMTemp C 11 07 10 19 8 14 2...

Страница 18: ...Stop bits 1 41110000000335 Upper Value 335 FPM Reading Decimal Place 0 3 Positive 0 Negative 1 C 01 F 02 m s 08 Knot 09 Km h 10 FPM 11 mph 12 1 Upper display value 2 Lower display value 4 410101000002...

Страница 19: ...batteries must be replaced 1 Remove the two 2 Phillips screws on the back of the meter directly located above the top of the kickstand 2 Remove the battery cover 3 Replace 6 x AA batteries 4 Secure t...

Страница 20: ...for Battery life will depend on a number of factors Quality of Battery Whether the beeper is ON or OFF Whether the backlight is ON or OFF Environmental Conditions during data logging As a reference us...

Страница 21: ...2127 or info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposin...

Страница 22: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Отзывы: