background image

8

www.REEDInstruments.com

Battery Replacement

1.  Unscrew the battery cap 

counterclockwise as shown at right 
picture, and then replace the batteries 
according to the polarity indication.

2.  Tighten the battery cap clockwise and 

the buzzer will beep twice to indicate 
the completion of the replacement.

Product Care

To keep your instrument in good working order we recommend the following:
•  Store your product in a clean, dry place.
•  Change the battery as needed.
•  If your instrument isn't being used for a period of one month or longer 

please remove the battery.

•  Clean your product and accessories with biodegradable cleaner. Do not 

spray the cleaner directly on the instrument. Use on external parts only.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 800837005960

Страница 1: ...www REEDInstruments com Non Contact Voltage and Magnetic Field Detector Instruction Manual R5120 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ning the Detector ON OFF 6 Turning the Flashlight ON OFF 6 AC Voltage Detection 7 High Low Voltage Detection Modes 7 Magnetic Field Detection Mode 7 Low Battery Indicator 7 Auto Power Off 7 Battery Re...

Страница 3: ...facturer s warranty Servicing should only be provided by an authorized service center Do not use the product if it appears to be damaged or isn t operating properly Do not apply more than the specifie...

Страница 4: ...determine the presence of magnetic fields Double insulated housing for increased safety Audible buzzer and visual LED indicators Built in flashlight Pocket clip Auto shut off Cat IV 1000V safety rati...

Страница 5: ...ery Indicator Yes Power Supply 2 x AAA batteries Overvoltage Category CAT IV 1000V Product Certifications CE IP67 ETL Conforms to UL STD 61010 1 61010 2 030 Certified to CSA STD C22 2 No 61010 1 61010...

Страница 6: ...ice and the red indicator light will illuminate indicating that the detector is on and ready for use The default voltage detection range is set to High 90 to 1000VAC Press and hold the power button ag...

Страница 7: ...ctrical interference noise Please only use low voltage mode during weak electrical field environment Magnetic Field Detection Mode The magnetic field detection function can be used to to quickly deter...

Страница 8: ...lacement Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Change the battery as needed If your instrument isn t being used...

Страница 9: ...849 2127 or by email at info REEDInstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulatio...

Страница 10: ...www REEDInstruments com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Отзывы: