background image

7

www.REEDInstruments.com

AC Voltage Detection

Place the NCV sensor head near the test object or the power socket with 
AC voltage. When AC voltage is detected, the red LED in the tip and 
audible alarm will turn on.

High/Low Voltage Detection Modes

1.  When the detector is powered on the red indicator light on the panel 

will light up indicating the default voltage detection range is set to 
High (90 to 1000VAC).

2.  Press the power button once and the red indicator light will switch to 

green indicating the detector is now in Low Voltage Mode  
(24 to 1000VAC). In low voltage mode, the detector is more sensitive 
to electrical interference/noise. Please only use low voltage mode 
during weak electrical field environment.

Magnetic Field Detection Mode

The magnetic field detection function can be used to to quickly determine 
if components are working properly (i.e. Solenoid valves, relays, 
contactors, permanent magnets, electromagnets, etc.).

To use the magnetic field function, press the power button until the yellow 
indicator light on the instrument panel lights up. When a magnetic field is 
detected the buzzer will beep and the indicator light will illuminate.

Low Battery Indicator

When the battery voltage is lower than 2.4V, the detector will automatically 
turn OFF.

Auto Power Off

The detector will auto power off when it is not used for 5 minutes.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 800837005960

Страница 1: ...www REEDInstruments com Non Contact Voltage and Magnetic Field Detector Instruction Manual R5120 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ning the Detector ON OFF 6 Turning the Flashlight ON OFF 6 AC Voltage Detection 7 High Low Voltage Detection Modes 7 Magnetic Field Detection Mode 7 Low Battery Indicator 7 Auto Power Off 7 Battery Re...

Страница 3: ...facturer s warranty Servicing should only be provided by an authorized service center Do not use the product if it appears to be damaged or isn t operating properly Do not apply more than the specifie...

Страница 4: ...determine the presence of magnetic fields Double insulated housing for increased safety Audible buzzer and visual LED indicators Built in flashlight Pocket clip Auto shut off Cat IV 1000V safety rati...

Страница 5: ...ery Indicator Yes Power Supply 2 x AAA batteries Overvoltage Category CAT IV 1000V Product Certifications CE IP67 ETL Conforms to UL STD 61010 1 61010 2 030 Certified to CSA STD C22 2 No 61010 1 61010...

Страница 6: ...ice and the red indicator light will illuminate indicating that the detector is on and ready for use The default voltage detection range is set to High 90 to 1000VAC Press and hold the power button ag...

Страница 7: ...ctrical interference noise Please only use low voltage mode during weak electrical field environment Magnetic Field Detection Mode The magnetic field detection function can be used to to quickly deter...

Страница 8: ...lacement Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Change the battery as needed If your instrument isn t being used...

Страница 9: ...849 2127 or by email at info REEDInstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulatio...

Страница 10: ...www REEDInstruments com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Отзывы: