background image

VADA   

TWIN MOTOR MACERATOR

Commissioning:

•  Once the plumbing and electrical connections have been made, check that the connections are watertight by letting the 

water flow successively through each inlet used. Make sure that the unit is operating correctly by carrying out at least two 
start cycles with water to test the system. 

•  DO NOT operate the motors in override status (by pressing the pushbuttons on the control box) until the pumps have filled 

with water. Operation without water damages the maceration system.

Care and use:

•  DO NOT dispose of solvents, paints, turps, caustic acid, or other corrosive acids or cleaners.
•  DO NOT dispose of foreign objects, feminine hygiene products, wet wipes, paper hand towels in the system.
•  DO NOT dispose of hot water in excess of 70ºC.
•  DO NOT use cleaning products that produce excessive foam, this may cause motor damage.
•  DO NOT install in a hairdressing salon without the use of a hair trap first. 
•  DO periodically clean the macerator with a quality cleaning product on the market that is not acid/citric based.
•  In the event of a power failure, stop draining any water from the equipment connected to the unit.
•  A visual check of the unit must be conducted once a month to ensure correct operation. The installation must be inspected 

regularly (once a year) by a qualified plumber.

Disclaimer Products in this specification manual must by regulation be installed by licensed and 
registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete 
models from their range without prior notification. Dimensions and set-outs listed are correct at time of 
publication however the manufacturer/distributor takes no responsibility for printing errors.

TROUBLESHOOTING:

SYMPTOMS

PROBABLE CAUSES

REMEDIES

Alarm + general alarm LED flashing

• 

Faulty detection system

• 

Contact service/installation support

Alarm + general alarm LED lit

• 

Blocked pipe

• 

Pump is blocked or seized

• 

Reset the pumps (MO button) in several 
bursts

• 

Contact service/installation support

General alarm LED

• 

Blocked pipe

• 

Blocked vent pipe

• 

Pump is blocked or seized

• 

The unit has been affected by a mains 
power cut

• 

Press one of the two MO buttons to 
reset (alarm will then stop)

Alarm + general LED + yellow mains 
LED flashing

• 

Mains power has been cut to the unit

• 

Press one of the two MO buttons to 
reset (alarm will then stop)Contact 
service/installation support

• 

Check the electrical system/connection

• 

Contact service/installation support

Pumps is working constantly

• 

Outlet pipe is blocked

• 

Discharge head is too high

• 

Faulty detection system

• 

Faulty electronic board

• 

Unblock the outlet pipe

• 

Check the installation*

• 

Contact service/installation support

Pumps work intermittedly

• 

Faulty non return valve

• 

Leaking toilet cistern and/or taps

• 

Clean or check the valves

 

MO: Manual Override

Service/installation support: 

AUS: 1300 554 779
NZ: (09) 390 4615

page 6 of 7

Содержание VADA TWIN MOTOR MACERATOR

Страница 1: ...ximum Temperature 70 C Inlets 5 Electrical Power Supply 220 240 V 50 Hz Motor Power Rating 2 X 1500 W Recommended Discharge Pipe Size DN40 uPVC pressure pipe Alarm Standard wired alarm panel Casing Grey Warranty 2 years Standards ATS 5200 101 2005 WMKA 23048 Disclaimer Products in this specification manual must by regulation be installed by licensed and registered trade people The manufacturer dis...

Страница 2: ... cutter MPR4 2 Cutter set COUCHI COUCHI42 3 Coupling disc COUCHI BL120124 4 Impeller nut M8 for COUCHI NP100710 5 Impeller R3 BL120308 6 Washer M8 NE100125 7 NRV set rubber COUDYR3 8 Level pressure switch CUBIC PRESNIV35CUBIC 9 Rubber holder for PRESNIV AU010171 10 Junction circuit board AC120174 11 Seal for electric panel AU010261 12 Grey Electric panel BL120540 13 Circuit board cubic 2 Classic W...

Страница 3: ...stalled to allow full access in the event that servicing or removal is required All incoming pipework must have a constant gradient of 1 40 Only ONE vertical lift is permitted in the discharge line All changes of direction in the discharge line MUST be made with 45 degree bends rather than 90 degree bends The unit has 5 possible inlet ports Installation of the unit is to be undertaken by a license...

Страница 4: ... errors VADA TWIN MOTOR MACERATOR FIG 1 FIG 3 Connecting incoming waste water 1 Connect the first waste line by cutting off the seal cap at the top of the unit with either a stanley knife or hacksaw 2 Connect the rubber connector to the outlet and tighten with a metal hose clamp Fig 1 3 Connect the remaining inlets via the diagrams in Fig 3 4 To connect the 100 110 incoming waste water remove the ...

Страница 5: ...or stars up 3 seconds later See Figure 4 Temporary alarm If one of the 2 motors runs for more than 1 minute the buzzer is triggered and the red LED light comes on The other motor starts up 3 seconds later Mains power supply In the event of a mains power failure or if the unit is unlugged the buzzer is triggered and the red LED light comes on The yellow mains power LED also flashes ALARM OPERATION ...

Страница 6: ...this specification manual must by regulation be installed by licensed and registered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at time of publication however the manufacturer distributor takes no responsibility for printing errors TROUBLESHOOTING SYMPTOM...

Страница 7: ... accordance with the instructions provided This warranty does not cover products purchased as an ex display without being fully checked and tested for sale by the manufacturer This warranty does not include faults caused by Unsuitable or improper use Incorrect installation or installation not in accordance with the instructions provided Installation or part installation by the purchaser or any per...

Отзывы: