background image

Disclaimer Products in this specification manual must by regulation be installed by licensed and 
registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete 
models from their range without prior notification. Dimensions and set-outs listed are correct at time of 
publication however the manufacturer/distributor takes no responsibility for printing errors.

VADA   

TWIN MOTOR MACERATOR

FIG 1

FIG 3

Connecting incoming waste water:

1.  Connect the first waste line by cutting off the seal cap at the top of 

the unit with either a stanley knife or hacksaw.  

2.  Connect the rubber connector to the outlet and tighten with a metal 

hose clamp (Fig 1).

3. Connect the remaining inlets via the diagrams in Fig 3.
4. To connect the 100/110 incoming waste water, remove the plug  
  from the side inlets and fix the sleeve in place using a collar. Fully  
  insert the 100/110 pipe in the other end of sleeve and fix in place  
  with a clamp.

Ø 40/50mm

27 cm 

min

FIG 2

page 4 of 7

Содержание VADA TWIN MOTOR MACERATOR

Страница 1: ...ximum Temperature 70 C Inlets 5 Electrical Power Supply 220 240 V 50 Hz Motor Power Rating 2 X 1500 W Recommended Discharge Pipe Size DN40 uPVC pressure pipe Alarm Standard wired alarm panel Casing Grey Warranty 2 years Standards ATS 5200 101 2005 WMKA 23048 Disclaimer Products in this specification manual must by regulation be installed by licensed and registered trade people The manufacturer dis...

Страница 2: ... cutter MPR4 2 Cutter set COUCHI COUCHI42 3 Coupling disc COUCHI BL120124 4 Impeller nut M8 for COUCHI NP100710 5 Impeller R3 BL120308 6 Washer M8 NE100125 7 NRV set rubber COUDYR3 8 Level pressure switch CUBIC PRESNIV35CUBIC 9 Rubber holder for PRESNIV AU010171 10 Junction circuit board AC120174 11 Seal for electric panel AU010261 12 Grey Electric panel BL120540 13 Circuit board cubic 2 Classic W...

Страница 3: ...stalled to allow full access in the event that servicing or removal is required All incoming pipework must have a constant gradient of 1 40 Only ONE vertical lift is permitted in the discharge line All changes of direction in the discharge line MUST be made with 45 degree bends rather than 90 degree bends The unit has 5 possible inlet ports Installation of the unit is to be undertaken by a license...

Страница 4: ... errors VADA TWIN MOTOR MACERATOR FIG 1 FIG 3 Connecting incoming waste water 1 Connect the first waste line by cutting off the seal cap at the top of the unit with either a stanley knife or hacksaw 2 Connect the rubber connector to the outlet and tighten with a metal hose clamp Fig 1 3 Connect the remaining inlets via the diagrams in Fig 3 4 To connect the 100 110 incoming waste water remove the ...

Страница 5: ...or stars up 3 seconds later See Figure 4 Temporary alarm If one of the 2 motors runs for more than 1 minute the buzzer is triggered and the red LED light comes on The other motor starts up 3 seconds later Mains power supply In the event of a mains power failure or if the unit is unlugged the buzzer is triggered and the red LED light comes on The yellow mains power LED also flashes ALARM OPERATION ...

Страница 6: ...this specification manual must by regulation be installed by licensed and registered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at time of publication however the manufacturer distributor takes no responsibility for printing errors TROUBLESHOOTING SYMPTOM...

Страница 7: ... accordance with the instructions provided This warranty does not cover products purchased as an ex display without being fully checked and tested for sale by the manufacturer This warranty does not include faults caused by Unsuitable or improper use Incorrect installation or installation not in accordance with the instructions provided Installation or part installation by the purchaser or any per...

Отзывы: