background image

35 

 

1.28 Optional equipment for Ethernet Home Automation connection

 

CML5

B  

Home 

Automa)on 

System by 

others 

CGB2C35 

This special cable is specific for 

connec)ng the CM225 and 

Wired Bridge  

Power supply, 

Zone motors and 

CMEXT not shown 

for clarity 

Ethernet 

Op onal wireless 

communica ons between 

CML5B and CM225  

CM225 

Содержание Myzone Naked 400

Страница 1: ...Systems Reece Pty Ltd reserves the right to change or modify the design speci ca ons so ware hardware rmware or Apps at any me without prior wri en or oral no ce Images and func ons in this manual sh...

Страница 2: ...1 10 Myzone Nano 420 Wiring layout for up to 14 zones 17 1 11 Myzone Nano 425 Wiring layout for up to 8 zones 18 1 12 Myzone Nano 425 Wiring layout for up to 14 zones 19 1 13 Myzone Nano 430 Wiring l...

Страница 3: ...tion connection 35 1 29 Integrated Myzone A C Lights Irrigation Security 36 1 30 Myzone wiring connection to AC units 37 1 30 1 Myzone wiring connection to Actron units 38 1 30 2 Myzone wiring connect...

Страница 4: ...e 1 stage reverse cycle heat pump 3 x fan speed 56 1 31 8 Universal Control Module 1 stage reverse cycle heat pump auxiliary heating 1 x fan speed 57 1 31 9 Universal Control Module 2 stage reverse cy...

Страница 5: ...art phone and tablet configuration System requirements 81 3 5 4 Smart phone and tablet configuration Equipment required and Configuration 82 3 5 5 Smart phone and tablet configuration Using you App 83...

Страница 6: ...9 Favourites 95 4 10 Assigning and editing favourites 96 4 11 Schedules 97 4 12 Setting and editing a schedule 98 4 13 Setting the time 99 4 14 Changing the home screen colour 100 4 15 iSense controll...

Страница 7: ...7 This page has been inten onally le blank for your notes...

Страница 8: ...one 5 Zone 3 Zone 7 Zone 8 Zone 4 Zone 6 Zone 2 8 Zone system with wireless remote control shown above A maximum of 14 zones can be supported by one Myzone system Any touchscreen temperature sensor or...

Страница 9: ...5 Zone 3 Zone 7 Zone 8 Zone 4 Zone 6 Zone 2 14 Zone system with wireless remote control shown above Any touchscreen temperature sensor or iSense controller can be added as an optional extra CMEXT Zon...

Страница 10: ...ith WiFi control shown above A maximum of 14 zones can be supported by one Myzone system Any touchscreen temperature sensor or iSense controller can be added as an optional extra CML5BK Wireless Bridg...

Страница 11: ...one 6 Zone 2 14 Zone system with WiFi control shown above Any touchscreen temperature sensor or iSense controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone...

Страница 12: ...cable See table for loca on of connec on in AC unit 1 30 Make sure you have the correct model for the brand of AC unit 8 Zone system with wireless remote control shown above A maximum of 14 zones can...

Страница 13: ...remote control shown above Any touchscreen temperature sensor or iSense controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cabl...

Страница 14: ...Make sure you have the correct model for the brand of AC unit 8 Zone system with WiFi control shown above A maximum of 14 zones can be supported by one Myzone system Any touchscreen temperature sensor...

Страница 15: ...nse controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cable See table for loca on of connec on in AC unit 1 30 Make sure you h...

Страница 16: ...e See table for loca on of connec on in AC unit 1 30 Make sure you have the correct model for the brand of AC unit CMCTS 8 Zone system with one Nano touchscreen shown above A maximum of 14 zones can b...

Страница 17: ...no touch screen shown above Any touchscreen temperature sensor or iSense controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cab...

Страница 18: ...he correct model for the brand of AC unit 8 Zone system with Nano touchscreen WiFi control shown above A maximum of 14 zones can be supported by one Myzone system Any additional touchscreen temperatur...

Страница 19: ...ure sensor or iSense controller can be CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cable See table for loca on of connec on in AC unit 1 30 Make sure you have the co...

Страница 20: ...See table for loca on of connec on in AC unit 1 30 Make sure you have the correct model for the brand of AC unit CMCTSL 8 Zone system with one Nexus touchscreen shown above A maximum of 14 zones can...

Страница 21: ...xus touchscreen shown above Any touchscreen temperature sensor or iSense controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cab...

Страница 22: ...correct model for the brand of AC unit CMCTSL 8 Zone system with one Nexus touchscreen WiFi control shown above A maximum of 14 zones can be supported by one Myzone system Any additional touchscreen...

Страница 23: ...or or iSense controller can be added as an optional extra CMT24AC Zone 11 Zone 9 Zone 13 Zone 14 Zone 10 Zone 12 AC Unit AC unit control cable See table for loca on of connec on in AC unit 1 30 Make s...

Страница 24: ...Zone system shown above VAV4 A maximum of 14 zones and 14 iSense controllers can be supported by one Myzone system For VAV1 to VAV3 no CNEM is required CMT24AC CMT24AC CNEM Network Extension Module C...

Страница 25: ...air duct o the fan coil unit Must be installed on all zone temperature controlled systems CRFS op onal Wireless Temperature Sensors Max 14 per system CR op onal Wireless Repeaters To extend wireless r...

Страница 26: ...t Must be installed on all zone temperature controlled systems CS op onal Wired Temperature Sensors Max 14 per system CWSM op onal Install Sensor Module to allow for Wired temperature sensors CS CWSM...

Страница 27: ...nstalled on all zone temperature controlled systems CZCO iSense op onal Wired Zone Controllers with temperature and occupancy sensor Max 12 per system CMT24A CNEM op onal Install Network Extension Mod...

Страница 28: ...coil unit Must be installed on all zone temperature controlled systems CMT24A CNEM op onal Install Network Extension Module to provide addi onal network ports if required Power supply Zone motors and...

Страница 29: ...ne Controllers with temperature and occupancy sensor Max 12 per system Connect Sensor module to any network port in the system Myzone Net port CMT24A CRFS Wireless Temperature Sensors Max 14 per syste...

Страница 30: ...CMCTSL Nexus colour touch screen will display both systems 1 and system 2 CMCTS Nano colour touch screen serving System 2 only CISM System 1 System 2 Notes 1 When using the mul plexer you cannot use t...

Страница 31: ...ystem CML5B Wired Bridge Customers router or modem CGB2C35 This special cable is speci c for connec ng the CPU and Wired Bridge Power supply Zone motors and CMEXT not shown for clarity Ethernet Downlo...

Страница 32: ...r wireless WiFi control of system CML5B Wireless Bridge Customers router or modem CR op onal Wireless Repeaters Power supply Zone motors and CMEXT not shown for clarity Download the Myzone3 App to you...

Страница 33: ...n 8 zone system it is limited to a maximum of 6 Zones Return Air Damper 1 Return Air Damper 2 Outside Air Air Damper 1 Outside Air Air Damper 2 CDAK Use Zone 8 port on CM225 for Outside Air dampers Us...

Страница 34: ...one system is lim ited to a maximum of 12 Zones Return Air Damper 1 Return Air Damper 2 Outside Air Air Damper 1 Outside Air Air Damper 2 CDAK Use Zone 14 port on CMEXT for Outside Air dampers Use Zon...

Страница 35: ...connection CML5 B Home Automa on System by others CGB2C35 This special cable is speci c for connec ng the CM225 and Wired Bridge Power supply Zone motors and CMEXT not shown for clarity Ethernet Op on...

Страница 36: ...rs and 12 colour touch screens can be supported by one Myzone system Customers router or modem CML5B Wireless Bridge tablet CR op onal Wireless Repeaters Lights Max 128 CMT24 AC Unit Myzone AC control...

Страница 37: ...sal control module covers units with standard 24V control See detailed instructions on 2 31 to 2 31 9 pages 49 58 Unit Make Connection Actron See detailed instructions on 1 30 1 page 38 Daikin Take th...

Страница 38: ...14kw 1 Connect a shielded 2 core twisted pair control cable from the CM225 CM325A to the X Y in the fan coil unit This cable and connector is supplied by Actron Polarity is critical see Fig i J K bel...

Страница 39: ...ier to CN24 in the fan coil unit of the Haier Interface board YCJ A002 Set the dipswitches as shown below Polarity is critical Fig N Myzone CM225 CM325HI Fig L Haier Interface board Model YCJ A002 Fis...

Страница 40: ...rminals and earth in the in the fan coil unit This cable is supplied by the installer Polarity is not critical see Fig H for correct connection Fig H Hitachi indoor fan coil unit terminals L1 Indoor U...

Страница 41: ...he CM225 CM325KAD to the X Y in the fan coil unit This cable and connector is supplied by Kaden Polarity is critical see Fig i J K below for correct connection X Y E 12V CN40 Connector Pin out Fig i I...

Страница 42: ...e CM225 CM325KEL to the X Y in the fan coil unit This cable and connector is supplied by Kelvinator Polarity is critical see Fig i J K below for correct connection X Y E 12V CN40 Connector Pin out Fig...

Страница 43: ...OFF 1 Connect a shielded 2 core twisted pair control cable from the CM225 CM325L to the PI485 Gateway M board in the condensing unit This cable is supplied by the installer Polarity is critical see F...

Страница 44: ...CM225 CM325MID to the X Y in the fan coil unit This cable and connector is supplied by Midea Polarity is critical see Fig i J K below for correct connection X Y E 12V CN40 Connector Pin out Fig i Ind...

Страница 45: ...e CM225 CM325R to the X Y in the fan coil unit This cable and connector is supplied by Rinnai Polarity is critical see Fig i J K below for correct connection X Y E 12V CN40 Connector Pin out Fig i Ind...

Страница 46: ...325S to the F3 F4 in the fan coil unit This cable is supplied by the installer Polarity is critical see Fig F G below for correct connection Fig F Samsung indoor fan coil unit terminals Shielded 2 cor...

Страница 47: ...er Polarity is critical see Fig A B for correct connection 2 Ensure the dip switches in the condensing unit are set correctly for the installed compressor type digital fixed speed and fan speed contro...

Страница 48: ...e CM225 CM325Y to the X Y in the fan coil unit This cable and connector is supplied by York Polarity is critical see Fig i J K below for correct connection X Y E 12V CN40 Connector Pin out Fig i Indoo...

Страница 49: ...tage Gas Heat 2 Stage Cool 1 x Fan Speed Reverse Cycle Op ons 1 Stage R C 1 x Fan Speed 1 Stage R C 3 x Fan Speed 1 Stage R C Aux Hea ng 1 x Fan Speed 2 Stage R C Aux Hea ng 1 x Fan Speed 1 Connect ca...

Страница 50: ...thermostat only COM Heat EQUIPMENT 24V Maximum Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select Gas Heat...

Страница 51: ...Maximum Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 1 Stage Gas Heat 1 x Fan Speed Press Next Next A...

Страница 52: ...aximum Cool Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 1 Stage Gas Heat 1 Stage Cool 1 x Fan Speed...

Страница 53: ...imum Cool Heat 2 Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 2 Stage Gas Heat 1 Stage Cool 1 x Fan S...

Страница 54: ...Cool 1 Heat 2 Cool 2 Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 2 Stage Gas Heat 2 Stage Cool 1 x F...

Страница 55: ...Fan 24V Maximum Comp Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 1 Stage R C 1 Fan Speed Press Next...

Страница 56: ...4V Maximum Comp Field wiring by installer Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 1 Stage R C 3 Fan Speed Press Next Next...

Страница 57: ...4V Maximum Comp Field wiring by installer Aux Heat Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 1 Stage R C Aux Heating 1 x Fan...

Страница 58: ...aximum Comp 1 Field wiring by installer Aux Heat Comp 2 Configure required functionality via touch screen as follows Go to Config AC Unit Setup Next press edit pencil Select 2 Stage R C Aux Heating 1...

Страница 59: ...to one of the Myzone Net ports on the CM225 using a short RJ45 cable 9 If any zone is temperature controlled connect an in Duct Temperature Sensor CDTS to the CDTS port Install the sensor into the sup...

Страница 60: ...tton on any colour touch screen The time to initialise the system will vary depending on the number of motors connected The system will also initialise when power is restored after a power failure Pro...

Страница 61: ...This image is an example only Your screen may display differently depending on the system type what options are selected and the configuration settings entered by your installing contractor MYZONE 425...

Страница 62: ...r screen may display differently depending on the system type what options are selected and the configuration settings entered by your installing contractor Landscape Press Modern if you want to chang...

Страница 63: ...e system type what options are selected and the configuration settings entered by your installing contractor Screen Configuration Press Screen Beep is on Landscape Unhide Retic Classic Display Hide Li...

Страница 64: ...onfiguration could result in damage to your air conditioning unit and system To configure your system click on the System Config icon on the home page Enter the system password wamfud and press the en...

Страница 65: ...nt Intuitive AC Unit Control Myzone Inventive Intelligent Intuitive No ofZones 4 No ofConstants 1 ZoneSetup ACUnitSetup Pairwirelessdevice iSave Options WiFiBridgeConfig ChangePassword MyzoneDeviceLis...

Страница 66: ...ates this zone is designated to be the rst electronic constant zone Indicates this zone is ed with a wired sensor Touch here to change Indicates this zone temperature is controlled via the sensor in a...

Страница 67: ...s Sensor The con gura on of this zone can be changed by simply selec ng the appropriate bu on Please note the correct hardware must be ed for the zone to work correctly Myzone Inventive Intelligent In...

Страница 68: ...n the sensor in this zone Touch here to go back and save any changes Myzone Inventive Intelligent Intuitive AC Unit Control Myzone Inventive Intelligent Intuitive Sensorbatterystatus Good ChangeRfChan...

Страница 69: ...Pairing bu on on the wireless device At the same me press the Pairing Bu on on the touch screen see 3 2 1 and wait un l the update is complete Pair Note To pair other devices such as a Myzone bridge o...

Страница 70: ...adjust the calibra on down by 0 1 deg C Total calibra on o set from manufactured seEng Touch here to go back and save the changes Kitchen Calibratesensor 22 2 Down Up 0 2 Re calibrated temperature for...

Страница 71: ...rategy con gura on menu Follow the prompts to select the most appropriate strategy for your room or use the Custom Setup op on to design your own strategy Indicates the iSense has been ac vated on thi...

Страница 72: ...ive Intelligent Intuitive Myzone AC Unit Control Myzone Inventive Intelligent Intuitive ACUnitControllingSensor ACUnit Setup R Air Master Zones Automodedeadband Deadband Indicates the current dead ban...

Страница 73: ...lligent Intuitive Myzone Unit Capacity kW 14 Fan Air ow l s 1020 Touch here to con gure the zone areas 3 3 2 FanAutoConfig Capacities EnableFanAutoControl Auto Fan Touch here to ne tune the air ow cap...

Страница 74: ...ea in square meters Myzone Inventive Intelligent Intuitive Inventive Intelligent Intuitive Myzone Living 33 Touch here to go to the next 3 zones FanAutoConfig Zone2 Area sqm Zone1 Area sqm Kitchen 10...

Страница 75: ...ter SlaveSettings UnitInfo Panasonic System can be turned On and O via the Myzone controller and another non Myzone controller connected to the Panasonic unit Fault History Myzone Other On O Mode Fan...

Страница 76: ...elligent Intuitive Myzone Inventive Intelligent Intuitive Note Information on the configuration screen may vary depending which devices are connected to the system and which model of Myzone you have S...

Страница 77: ...t Intuitive Note Information on the configuration screen may vary depending which devices are connected to the system and which model of Myzone you have SystemOptions Locks TemperatureAdjustment Airfl...

Страница 78: ...3123 WiFi BridgeConfig IP 192 118 27 69 MAC 00 04 A5 G9 32 39 Displays the Myzone system iden ca on number Displays the Bridge IP address allocated by the DHCP Displays Myzone Ethernet controller MAC...

Страница 79: ...sses if applicable If you require manual con gura on please contact your IT specialist to assist you Touch here to go to the home screen Touch here to apply the changes to the con gura on Myzone Inven...

Страница 80: ...ymbol indicates the Myzone system is now connected to WiFi and ready to use A grey symbol indicates the Bridge is connected to the Myzone system but is not connected to the local computer network Myzo...

Страница 81: ...compatible WiFi modem or network switch with a spare RJ 45 access port Some WiFi modems firewalls and security settings are not compatible with the Myzone bridge and will need to be changed or replac...

Страница 82: ...ter the system password wamfud Pair the wireless bridge to the Myzone system Press and hold the blue button on the side of the Bridge At the same time press the Pair Wireless Device button on the touc...

Страница 83: ...system is connected to On the App press Register Now Complete all the fields making sure you get the Suburb State and Postcode 100 correct to ensure the correct weather data is displayed on your Nexu...

Страница 84: ...n system that has an Ethernet interface The WiFi bridge is fitted with an Ethernet connection For interface specifications please contact Reece Pty Ltd Your home automation integrator will need to wri...

Страница 85: ...225 module Zone 1 will ash blue rapidly You can also press the AC pair bu on on a touch screen if one is ed to the system Note Zone 1 will be set as the default constant zone when Auto configured Hint...

Страница 86: ...con gura on as it needs to receive data from each of the zone sensors 1 To pair the remote to the system Press and hold the pair bu on on the remote and at the same me press the pair bu on on the CM2...

Страница 87: ...ess to set system me 4 13 Press to con gure system 3 0 Press to ac vate or deac vate this screens audio feed back beep on touch Installing company s tag line will vary depending on the installa on com...

Страница 88: ...on gure a new favourite 4 9 Press to ac vate a schedule or to con gure a new schedule 4 11 Press to change screen seEngs 5 14 Press to con gure the system 3 0 A C system maintenance required or A C un...

Страница 89: ...the AC unit If a fault code appears here please contact your installer 4 3 AC unit control Press here to increase the AC unit set point Not applicable if AC unit controlling sensor Zones op on selecte...

Страница 90: ...Scroll up or down to see more zones 4 4 Zone control Indicates Zone 1 is in climate control mode Press here to change the Set point 4 6 Indicates this zone is closed Press here to open the zone Indic...

Страница 91: ...s to change maximum and minimum air ow set points Current zone being edited System zone number and display name Zone maximum and minimum air ow set points Status of this zone if it has been selected a...

Страница 92: ...ent zone set point temperature Press here to decrease the current zone set point temperature Press here to select this zone as the master only available if con gured for Master AC unit control Indicat...

Страница 93: ...zone Inventive Intelligent Intuitive Zone name Scroll up or down to see more zones Indicates current minimum air ow seEng to this zone Indicates current maximum air ow seEng to this zone Press here to...

Страница 94: ...rent minimum air ow seEng for this zone This is usually set at 0 Min Air ow will not display if this adjustment has been locked Press here to decrease the maximum air ow to this zone Press here to inc...

Страница 95: ...Inventive Intelligent Intuitive Press the favourite you would like and Myzone will automa cally change all the zones seEngs for this favourite Indicates this favourite has not been used Press here to...

Страница 96: ...change the name of this favourite Indicates what mode you want each zone to operate in when this favourite is used Change each zone seEng to suit your requirements for this favourite Press here to go...

Страница 97: ...Press here to enable the me based schedule for favourite PM Nap Press here to set up or edit a schedule on any favourite Indicates an automa c me schedule has been enabled for this favourite Indicate...

Страница 98: ...dule will apply Press to stop the schedule running on this day Press here to go back to the schedule summary Press here to clear this schedule Press the key pad to change the me Remember it is in 24 h...

Страница 99: ...ne Inventive Intelligent Intuitive Current me Indicates the minutes are be changed You must press the enter bu on to save the changes you have made Current date Press the le or right arrows to move to...

Страница 100: ...go back to the home screen Press the colour you would like for your home screen Fine adjustments to the shade tone hue can be made using the brightness contrast and satura on slides Slide le right to...

Страница 101: ...the zone opera ng The use of the iSense feature in bedrooms when occupants are sleeping is not recommended System reset bu on under here Press to Open this zone fully Indicates zone setpoint temperatu...

Страница 102: ...s here to toggle through the zones If two LED s are illuminated the seEng is in the middle eg 95 Press to open the current zone Press here to move down to the next zone or if pressed a er the air bu o...

Страница 103: ...r bu on only to be used for con gura on Press here turn the system on or o All connected zones will display red if the system is o If the system is currently on all connected zones will display green...

Страница 104: ...conditioning system or your MyZone system you should contact your installation company 2 If you want to add more zones or temperature control to any zone you should contact your installation company R...

Отзывы: