HIDEAWAY
ACTIVE SENSOR-FLUSH URINAL
Plumbers, please ensure a copy of the installation
instructions is left with the end user for future reference
HIDEAWAY
ACTIVE SENSOR-FLUSH URINAL
9.0
System Description and Technical Specification
0.8 litre Active Urinal with Hideaway Smart Demand Operation and Urine Sensing Device
•
The Sensor detects urine entering the urinal bowl and initiates a flush accordingly.
•
The Controller is equipped with a flush time adjustment and program selector switches.
•
Flush time can be selected depending on available dynamic pressure.
•
The Program Selector switch allows the selection of the appropriate setting to maximise water conservation
based on the expected usage as follows:
Program 1
(Normal Mode-Factory setting) flushes after every use and will automatically switch to Saver Mode (1 flush every
minute) when 4 users visit the urinal in less than 1 minute intervals no matter how many times used. 1 minute of non-use will
reset the control unit back to Normal Mode. Janitors Flush activates after 48 hours of non-use.
Program 2
(Eco Mode) flushes after every 3
rd
user or 15 minutes, whichever is first. Janitors Flush activates after 48 hours of
non-use.
•
Overflow protection, avoids overflow in the case of a pipe blockage where the urine sensing device ceases to
activate further flushing once the urinal bowl has filled.
•
Self-diagnostic fault finding.
•
Sensor is concealed to protect against vandlism.
Operating voltage mains powered model:
240 V AC
Operating voltage battery powered model:
6V DC
Power consumption:
0.3 W
Output:
6 V DC
Flushing time:
Selectable based on available dynamic pressure
Minimum dynamic pressure:
275kPa
Maximum dynamic pressure:
475kPa
Minimum connection pipe size:
DN20
Minimum flowrate:
18 litres/minute (l/min)
page 12 of 16