HIDEAWAY

ACTIVE SENSOR-FLUSH URINAL

Plumbers, please ensure a copy of the installation 
instructions is left with the end user for future reference

HIDEAWAY

ACTIVE SENSOR-FLUSH URINAL

10.0 

Diagnostic Function: 

To assist in finding faults in the electronic components 

the controller is equipped with a diagnostic function.  Follow the 

instructions below to activate this function. 

1)

Press and hold down ‘Button 1’ (flush time) for 10 to 20 seconds.

While holding the

button the LED will flash dimly, which is normal.

2) After 10 to 20 seconds release the button.

3) The LED will now flash in a bright sequence as outlined below. This LED flash

 

sequence is consecutive and check

s

 for 5 potential faults.

Between each fault check the LED will switch off for a 5 second pause.

DIAGNOSTIC FUNCTION

CORRECTIVE ACTION RESPONSE

Battery Power check:

One long flash = Battery OK

OR

Multiple flashes = Battery Power LOW

Note:

This check is for battery power controller checking only, not 

mains power

Operating correctly

Replace battery

Problem fixed

If problem cannot be resolved 

call 07 3875 2465

5 seconds pause

Pause then, Capacitive Sensor check:

One long flash = Sensor OK

OR

Multiple flashes = Capacitive Sensor not OK

Operating correctly

Ensure sensor cable is connected correctly at both plug connections.

Re-start Urinal by turning power off and then on again after 30 seconds.

Check red LED response as soon as power is switched on (see 

Commissioning). Look for 2 confirmation flushes to confirm urinal is 

functioning normally.

Problem fixed

If problem cannot be resolved 

call 07 3875 2465 for assistance

5 seconds pause

Pause then, Temperature Sensor check:

One long flash = Sensor OK

OR

Multiple flashes = Temperature Sensor not OK

Operating correctly

Ensure sensor cable is connected correctly at both plug connections.

Re-start Urinal by turning power off and then on again after 30 seconds.

Check red LED response as soon as power is switched on (see 

Commissioning). Look for 2 confirmation flushes to confirm urinal is 

functioning normally.

Problem fixed

If problem cannot be resolved 

call 07 3875 2465 for assistance

5 seconds pause

Pause then, Solenoid Valve check:

One long flash = Solenoid Valve OK

OR

Multiple flashes = Solenoid Valve is not OK

Operating correctly

Ensure Solenoid Valve is connected.

Re-start Urinal by turning power off and then on again after 30 seconds.

Check red LED response as soon as power is switched on (see 

Commissioning). Look for 2 confirmation flushes to confirm urinal is 

functioning normally.

Problem fixed

If problem cannot be resolved 

call 07 3875 2465 for assistance

5 seconds pause

Pause then, indicates Average user statistics over the past 30 

days.

1.

Flash = less than 20 usages per day

2.

Flashes = between 20 and 60 usages per day

3.

Flashes = more than 60 usages per day

Pause then, Completion of Diagnostic Mode is followed by 2 

confirmation flushes.

Informative only, no action required.

In the event of power being disconnect or switched off, all user settings and functions are retained by the Flush Control Unit. 

Button 1 

page 13 of 16

Содержание HIDEAWAY

Страница 1: ...ions or queries during installation please contact Tech Support for phone assistance free call 07 3875 2465 We are happy to assist you Dear Customer This is the warranty by Reece Pty Ltd relating to t...

Страница 2: ...d valve is fitted with 200mm cable and 2 pin connector Fig 1 Cables are supplied as follows Sensor extension cable 2500mm long with female male 4 pin connectors 1800mm power cable wired with single ma...

Страница 3: ...mum size not supplied free of kinks for sensor extension cable Fig 4 7 Fit single 240 volt 10 amp GPO for transformer power supply unit adjacent to proposed location of controller 3 0 Control Unit Con...

Страница 4: ...V flush with finished wall Fig 7 5 Fit kee seal to waste trap and lubricate before gently pushing into 50mm PVC DWV pipe so trap finishes flush with face of wall Fix waste trap to wall with single scr...

Страница 5: ...r C Do not press buttons on the controller yet LED FLASH RESPONSE FIRST TIME POWER ON MEANING 1 Initial 2 short ashes followed by steady flashes at 1 second intervals After about 25 seconds of steady...

Страница 6: ...ns in the male plug are not bent apart and line up with the holes in the female plug If required use your fingers to squeeze the plug and pins together 3 Check plug alignment and re connect Re connect...

Страница 7: ...Schools This program will ush the urinal only after every 3 rd user or 15 minutes after use whichever comes rst It also triggers a janitor s ush after 48 hours of non use Button 2 To change the progr...

Страница 8: ...onnection Now the ushing is suspended for 30 minutes 3 Add more of the cleaning agent to the water of the urinal After 30 minutes a ush will automatically trigger and the urinal is ready for use How t...

Страница 9: ...instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Use the following figures to provide installation guidance Fig 11 In ceiling ins...

Страница 10: ...NSOR FLUSH URINAL Plumbers please ensure a copy of the installation instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig...

Страница 11: ...HIDEAWAY ACTIVE SENSOR FLUSH URINAL HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig 13 page 11 of 16...

Страница 12: ...ically switch to Saver Mode 1 flush every minute when 4 users visit the urinal in less than 1 minute intervals no matter how many times used 1 minute of non use will reset the control unit back to Nor...

Страница 13: ...sioning Look for 2 confirmation flushes to confirm urinal is functioning normally Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance 5 seconds pause Pause then Temperature Se...

Страница 14: ...ge is blocked Dynamic pressure has changed Un screw the solenoid cartridge and rinse out dirt out of the strainer see Section 1 Maintenance of the Solenoid Cartridge Check dynamic pressure and reset f...

Страница 15: ...enoid cartridge lubricate the two O Rings with a suitable tap O Ring lubricant Hydroseal tap lubricant or equivalent Note Do not over tighten The max torque is 1Nm hand tight 13 0 Spare parts 9503303...

Страница 16: ...RINAL INLET OUTLET SEAL 200 034 9503309 HIDEAWAY URINAL SOLENOID CARTRIDGE 200 036 9503310 HIDEAWAY URINAL SOLENOID BODY 200 037 9503311 HIDEAWAY URINAL AIR BREAK 200 038 9503312 HIDEAWAY URINAL FLUSH...

Отзывы: