Circuit diagram
S1
-
MICRO-SWITCH
SA
-
TEMPERATURE LIMITER
EH ELECTRIC ELEMENT
HL1 POWER INDICATOR
HL2 HEATING INDICATOR
E
-
EARTH GROUND
SB TEMPERATURE CONTROLLER
NOTE:
THE CIRCUIT PRINCIPLE OF RO SERIES 1-TANK/2-TANK
ELECTRIC FRYER IS DIFFERENT. THE DIFFERENCE IS THAT 2-TANK
ELECTRIC FRYER HAS TWO TANKS AND TWO ELECTRIC BOXES AND
TWO SEPARATE TEMPERATURE CONTROLLERS.
Instruction
1. Check if the installation of power supply is normal, and make sure the
supplied voltage is coordinated with the required voltage.
2. There is oil level mark in the internal oil tank; the quantity of oil in the
tank should be kept at between the lines
. “MAX” shows the most volume
of oil, “MIN” shows the minimum volume of oil.
3. 1) Plug the machine in, green indicator light will show when power is on.
2) Rotate the temperature controller clockwise; select the temperature
using the red pointer. At that time, the yellow indicator is on and green
indicator is off. This indicates that that electric heating element is
working and temperature of oil in tank is rising.
4. 1) When temperature is achieved the indicator turns off.
2) When oil temperature is reduced the temperature
controller turns the
power on automatically. When the yellow
indicator is on and green
indicator is off; the electric element works
again to bring the oil up to
temperature.