background image

RHF-3316

7

ENG

Technical Specifications 

Model

.................................................................................................................................................

RHF­3316

Rated power

 ...........................................................................................................................................105 W

Voltage

 ........................................................................................................................

220–240 V, 50/60 Hz

Electrical safety

 ....................................................................................................................................

class II

Water tank capacity

 .....................................................................................................................................5 L

Maximum humidity output

 ...........................................................................................................

400 ml/h

Recommended coverage area

 .................................................................................................

up to 35 m²

Control panel

 .........................................................................................................................................

sensor

Display

...........................................................................................................................................................LED

Remote control

 .................................................................................................................................

available

Steam output

 .......................................................................................................

2 nozzles, 360° rotation

Humidity level adjustment

 ..............................................................................................................

40­80%

Steam intensity adjustment

 .............................................................................................................

3 levels

Maintaining the selected humidity level

 ................................................................................

automatic

Automatic shut­off

 ......................

when there is no water in the tank; when the tank is removed

Additional features:

• 

Warm steam

• 

Ionization

• 

Aromatization function

• 

Night mode

Disconnecting timer

 .............................................................................................................

up to 10 hours

Operating temperature range

 ...........................................................................................

from 5 to 40°С

Operating humidity level

 .............................................................................................................

up to 80%

Overall dimensions

 ..................................................................................................

227 × 367 × 152 mm

Net weight

 ............................................................................................................................................2.85 kg

Power cord length

 ..................................................................................................................................1.5 m

Package Includes

Humidifier

 ...................................................................................................................................................1 pc.

Membrane cleaning brush

 .....................................................................................................................1 pc.

Remote control

 ..........................................................................................................................................1 pc.

Battery CR2025

 .........................................................................................................................................1 pc.

User manual

 ...............................................................................................................................................1 pc.

Service booklet

 ..........................................................................................................................................1 pc.

Manufacturer reserves the right to make any modifications to design, packaging, or technical 

specifications of the product without prior notice. The specification allows an error of ±10%.

Parts of Appliance 

(scheme 

A1

, p. 3–4)

1. 

Diffusor

2. 

Carrying handle

3.  Steam nozzles

4. 

Display

5. 

Sensor control panel

6. 

Water tank

7. 

Ultrasonic membrane

8. 

Lid for water tank with a dispenser

9. 

Membrane cleaning brush

10. 

Appliance base

11. 

Tray with a sponge for aromatic oils 

12. 

Power cord

13.  Float

Display 

(scheme 

A2

, p. 5)

1. 

Digital indicator

2. 

Humidity level indicator (%)

3.  Ambient temperature indicator (°С)

4. 

Timer function indicator

5. 

Humidification intensity indicator

6. 

Индикатор функции ионизации

7. 

Night mode indicator

8. 

Automatic mode indicator

9. 

Low water level indicator in the tank

10. 

“Warm Steam” function indicator

11. 

Indicator of maintaining the selected humidity level 

Control panel 

(scheme 

A2

, p. 5)

A. 

Ionization function on/off button

B. 

Night mode on/off button

C. 

Sleep timer setting button 

D. 

On/off button for the “Warm Steam” function

E. 

On/off button for automatic mode and humidity level adjustment

F. 

Humidification intensity adjustment button

G. 

The on/off button of the device 

Remote control 

(scheme 

A1

, p. 3)

a. 

Automatic mode on/off button 

b.  The on/off button of the device

Содержание RHF-3316

Страница 1: ...ENG Humidifier RHF 3316 User manual...

Страница 2: ...ling the water tank 8 Operation 8 Warm Steam function 9 Ionization function 9 Aromatization function 9 Humidification intensity adjustment 9 Humidity level adjustment 9 Automatic mode 9 Night mode 9 S...

Страница 3: ...3 2 6 10 4 1 3 5 12 a c e g b d f h A1...

Страница 4: ...4 9 8 13 11 6 7 A1...

Страница 5: ...5 A B C D E F G 1 2 3 4 6 9 7 11 10 8 5 A2...

Страница 6: ...damaging the cord may lead to a failure that will not be covered by the warranty If the power cord is damaged it must be replaced by the manufacturer after sales service or similar qualified personne...

Страница 7: ...ons to design packaging or technical specifications of the product without prior notice The specification allows an error of 10 Parts of Appliance scheme A1 p 3 4 1 Diffusor 2 Carrying handle 3 Steam...

Страница 8: ...operation II OPERATING THE APPLIANCE The appliance operation is based on boiling water at room temperature This is possible due to the ultra low pressure in the working chamber achieved by vibrating t...

Страница 9: ...n The selected value on the display will blink several times and be automatically saved the display will show again the current humidity level and temperature If the selected humidity level is lower t...

Страница 10: ...loose or missing Place the cap firmly on the float rod Insufficient steam output intensity Temperature of water in the tankis too low Pour clean settled lukewarm water into the tank Too much water in...

Страница 11: ...40 21 337 1099 www asbis ro RU 198099 38 2 7 812 740 16 30 SK Import r distrib tor pre SR ASBIS SK spol s r o Tuhovsk 33 831 06 Bratislava Tel 440 2 32165111 www online asbis sk RS Uvoznik i servis za...

Страница 12: ...www redmond company www multicooker com www store redmond company www smartredmond com Made in China RHF 3316 ENG UM 1...

Отзывы: