-5-

 

Effective  2018-11-02

Bulletin No. DA30D-A

Drawing No. LP1078 

RS422/485

 

COMMS

 

PORT

The RS485 port of the DA30D can be used for RS485 or RS422

communication. There is a separate RJ connector for each option. Each
serial port has a pair of LEDs to indicate transmit and receive activity.

 

Note: All Red Lion devices connect A to A and B to B. Refer to 

www.redlion.net for additional information.

 

Examples

 

of

 

RS485

 

2

Wire

 

Connections

DH485

 

COMMUNICATIONS

  

The DA30D’s RS422/485 COMMS port can also be used for Allen

Bradley DH485 communications.

WARNING

DO NOT

 use a standard DH485 cable to connect this port to

Allen Bradley equipment. A cable and wiring diagram are available
from Red Lion at 

www.redlion.net/cables-drivers

.

TX

5V

8

1

7

2

TxB

TxA

130K

130K

5

TxEN (OC)

RX

130K

5V

130K

RxB

4

RxA

3

COMM

6

RS422/485 4-WIRE

CONNECTIONS

RS485 2-WIRE

CONNECTIONS

TxEN (OC)

TX/RX

130K

5

TxA

2

8

130K

5V

7

1

TxB

6

COMM

DAX0D TO RED LION RJ11

DAx0D:RJ45 Name RLC:RJ11 Name

5

TxEN

2

TxEN

6

COMM

3

COMM

1

TxB

5

B-

2

TxA

4

A+

DAX0D TO RED LION RJ45

DAx0D Name RLC:RJ45 Name

1,4

TxB

1,4

TxB

4,1

RxB

4,1

RxB

2,3

TxA

2,3

TxA

3,2

RxA

3,2

RxA

5

TxEN

5

TxEN

6

COMM

6

COMM

7

TxB

7

TxB

8

TxA

8

TxA

CRIMSON

®

 

3.1

 

SOFTWARE

Crimson 3.1 software is available as a no charge download from Red

Lion’s website. The latest version of the software is always available from
the website, and updating your copy is free.

STATUS

 

LEDS

There are three status LEDs that show system status by default, or they

may be be user configured via System Functions using Crimson 3.1.
Shown below is the default system status of the LEDs.

FACTORY

 

RESET

 

BUTTON

The factory reset button located on the bottom of the unit enclosure

near the SD card slot can be used to access the system console. Refer to
Crimson 3 System Console Technical Note at 

www.redlion.net/TNIA22

 for

access procedure and available options.

TROUBLESHOOTING

 

YOUR

 

DAx0D

If for any reason you have trouble operating, connecting, or simply have

questions concerning your new DAx0D unit, contact Red Lion’s technical
support.

Email: 

[email protected]

Website: 

www.redlion.net

Inside US: +1 (877) 432-9908

Outside US: +1 (717) 767-6511

LED

INDICATION

GREEN 

STEADY

Unit is powered.

BLUE

 FLASHING

Unit is in the boot loader

OFF 

No SD card is present.

STEADY

Valid SD card present.

FLASHING RAPIDLY

SD card being checked.

FLICKERING

SD card accessed.

FLASHING SLOWLY

Incorrectly formatted SD card present.

RED

FLASHING

Data tag is in an alarm active state.

STEADY

Data tag is in an alarm accepted state.

SOFTWARE/UNIT

 

OPERATION

Содержание DA30D

Страница 1: ...tual HMI The virtual HMI is programmed just like Red Lion s CR3000 series of HMIs Any standard web browser may be used to monitor or control the DA30D from a PC anywhere in the world The DAx0D is programmed with Red Lion s Crimson 3 1 software Crimson offers easy to use drag and drop communications configuration and is available as a no charge download from Red Lion s website DIMENSIONS In inches ...

Страница 2: ... COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Hazardous File E317425 Rugged IP40 enclosure 7 CONNECTIONS High compression cage clamp terminal block Wire Strip Length 0 3 7 5 mm Wire Gage Capacity 12 to 24 AWG 3 31 to 0 20 mm2 copper wire Torque 4 4 5 3 inch lbs 0 5 0 6 N m 8 CONSTRUCTION Polycarbonate enclosure with ...

Страница 3: ...ifference between a successful or troublesome installation Listed are some EMI guidelines for a successful installation in an industrial environment 1 A unit should be mounted in a metal enclosure which is properly connected to protective earth 2 Use shielded cables for all Signal and Control inputs The shield connection should be made as short as possible The connection point for the shield depen...

Страница 4: ...D CARD Insert the SD card into the slot provided with the card oriented as shown The card is inserted properly when the end of the card is flush with the DA30D case To remove the SD card push in slightly on the card CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along with pin outs is available f...

Страница 5: ...B 8 TxA 8 TxA CRIMSON 3 1 SOFTWARE Crimson 3 1 software is available as a no charge download from Red Lion s website The latest version of the software is always available from the website and updating your copy is free STATUS LEDS There are three status LEDs that show system status by default or they may be be user configured via System Functions using Crimson 3 1 Shown below is the default syste...

Страница 6: ...ery is correct and as shown in the diagram Re install the battery holder with battery into the DAx0D unit Enter new date and time using Crimson 3 1 software CAUTION Lithium battery Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Please note that the old battery must be disposed of in a manner that complies with yo...

Страница 7: ... 7 Effective 2018 11 02 Bulletin No DA30D A Drawing No LP1078 This page intentionally left blank ...

Страница 8: ... BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install com...

Отзывы: