4
Drawing No. LP1122
Revised 03 2020
MODULE HOT SWAPPING
If the area is known to be non-hazardous (free of ignitable
concentrations), then a module can be removed and/or installed
into a cradle attached to the controller while power is applied.
However, it is
NOT
recommended to connect to or remove from
the controller, a module/cradle pair or group of modules/cradles,
while power is applied. The power should be turned off anytime
a cradle or group of cradles (with or without modules) is plugged
into or removed from the controller.
BLOCK DIAGRAM
A
POWER
SUPPLY
+
-
VDC
DA SERIES HOST
DA 6UIN MODULE
E
ISOLATED
POWER
SUPPLY
INPUT 4
F
ISOLATED
INPUT 5
G
ISOLATED
INPUT 6
D
ISOLATED
INPUT 3
C
ISOLATED
INPUT 2
B
ISOLATED
INPUT 1
WIRING
WIRING CONNECTIONS
All power and input wiring must be in accordance with Class I,
Division 2 wiring methods and in accordance with the authority
having jurisdiction.
All conductors should meet voltage and current ratings for each
terminal. When wiring the module, use the numbers on the label
to identify the position number with the proper function. Strip
the wire, leaving approximately 0.3" (7.5 mm) of bare wire
exposed. Insert the wire into the terminal, and tighten.
INPUT CONNECTIONS
THERMOCOUPLE VOLTAGE
RTD
CURRENT
LEDs
STATUS LED
The red/green/blue Status LED is located at the top of the
module and provides information regarding the state of the
module. This includes indication of the various stages of the start-
up routine (power-up), as well as any errors that may occur.
LED COLOR(S)
MEANING
Flashing Blue
Module is booting.
Flashing Green
Module is switching to configuration.
Green
Module is performing normally.
Flashing Green/Purple
Module is performing auto calibration.
Flashing Blue/Yellow
Module is being flash upgraded by Crimson.
Flashing Red
Error: general error with module.
Flashing Red/Green
Error: module is controlling properly, but has lost
communication with the Host.
Flashing Yellow
Error: no bus frequency /module is not enumerated
Flashing Red/Green/Blue
Error: module is running the Factory Programming
Console.
CAUTION: Only UL listed wiring with temperature
ratings greater than 90 °C permitted for Class I, Division
2, Zone 2 and ATEX/IECex installations.
ATTENTION: Seul le câblage homologué UL avec des
températures nominales supérieures à 90°C est autorisé
pour les installations de classe I, Division 2 , zone 2 et
ATEX/IECex.
Terminals 17 to 24
Terminals 25 to 32
Terminals 9 to 16
Terminals 1 to 8
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
01
02
03
06
04
05
08
07
14
09
11
10
13
12
16
15
20
17
19
18
21
22
24
23
29
28
26
25
27
32
31
30
N/C
N/C
6
5
4
2
1
3
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
ISOL
ATED
ISOL
ATED
ISOL
ATED
ISOL
ATED
ISOL
ATED
ISOL
ATED
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
+
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
VDC-
VDC+
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC
LOAD
POWER
+
+
_
0-10V
4-20 mA
INPUT COM
TC/RTD+
RTD +EXC