AL1 : AL6 – Alarm LEDs

The red Alarm LEDs indicate the presence of an alarm. 

Whenever one of the alarms is active, the LED turns on.

FIRMWARE UPGRADE

The module’s firmware is stored in flash memory so that 

software/ hardware conflicts are avoided, and so features can be 

added in the future.

During a download, Crimson compares its own library of 

firmware files with those stored in the module. If they do not 

match, Crimson will download the necessary firmware.

RED LION CONTROLS TECHNICAL SUPPORT

If for any reason you have trouble operating, connecting, or 

simply have questions concerning your new DA Module, contact 

Red Lion’s technical support.

Support: 

support.redlion.net

Website: 

www.redlion.net

Inside US: +1 (877) 432-9908
Outside US: +1 (717) 767-6511
Red Lion Controls, Inc. 

20 Willow Springs Circle York, PA 17406

ORDERING INFORMATION

DESCRIPTION

PART NUMBER

DA 6 Universal Isolated Input Module

DA M00I0 UIN6I 0000

Spaces in listed part numbers are shown to improve readability, 

do not include when searching for or ordering these parts.

A listing of the entire DA Series family of products and accessories 

can be found at www.redlion.net.

Содержание DA Series

Страница 1: ...he 6UIN module Status LED shows general module health status Please reference the LED section for a list of LED functions SAFETY SUMMARY All safety related regulations local codes and instructions that appear in this document or on equipment must be observed to ensure personal safety and to prevent damage to either the device or equipment connected to it Do not use these products to replace proper...

Страница 2: ...rmity at 23 C after 20 minute warm up Probe Break Response If channel is enabled upscale drive Input Fault Alarm bit set high ALM LED illuminates 5 CURRENT INPUTS Ranges 0 20 mA or 4 20 mA Programmable Scaling 30 000 Input Impedance 10 Ohm Max Continuous Overload 100 mA Accuracy 0 1 of span Input Fault Response Upscale Drive Input Fault Alarm bit set high ALx LED illuminates below 2 mA and above 2...

Страница 3: ...very effective at reducing EMI and increasing relay contact life b If a DC inductive load such as a DC relay coil is controlled by a transistor switch care must be taken not to exceed the breakdown voltage of the transistor when the load is switched One of the most effective ways is to place a diode across the inductive load Most Red Lion products with solid state outputs have internal zener diode...

Страница 4: ... the various stages of the start up routine power up as well as any errors that may occur LED COLOR S MEANING Flashing Blue Module is booting Flashing Green Module is switching to configuration Green Module is performing normally Flashing Green Purple Module is performing auto calibration Flashing Blue Yellow Module is being flash upgraded by Crimson Flashing Red Error general error with module Fl...

Страница 5: ...irmware RED LION CONTROLS TECHNICAL SUPPORT If for any reason you have trouble operating connecting or simply have questions concerning your new DA Module contact Red Lion s technical support Support support redlion net Website www redlion net Inside US 1 877 432 9908 Outside US 1 717 767 6511 Red Lion Controls Inc 20 Willow Springs Circle York PA 17406 ORDERING INFORMATION DESCRIPTION PART NUMBER...

Страница 6: ...6 Drawing No LP1122 Revised 03 2020 This page intentionally left blank ...

Страница 7: ...7 Revised 03 2020 Drawing No LP1122 This page intentionally left blank ...

Страница 8: ...e local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install commission or maintain the Product according to specifications ii Customer alters or repairs such Product without the prior written consent of Company c Subject to paragraph b with respect to any such Product during ...

Отзывы: