background image

1

z

LCD, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE

WITH YELLOW/GREEN OR RED BACKLIGHTING

z

FOUR SELECTABLE D.C. RANGES

0 to 199.9 mV, 1.999 V, 19.99 V, 199.9 V (CUB4V)
0 to 199.9 µA, 1.999 mA, 19.99 mA, 199.9 mA (CUB4I)

z

0.6 INCH (15.2 mm) HIGH LCD DIGITS

z

BUILT-IN SCALING PROVIDED

z

AUTO ZEROING CIRCUIT

z

SELECTABLE DECIMAL POINTS

z

WIRE CONNECTIONS MADE VIA SCREW CLAMP TYPE

TERMINALS

z

FITS DIN STANDARD CUT-OUT 2.68" (68 mm) x 1.30" (33 mm)

z

NEMA 4X/IP65 SEALED FRONT PANEL BEZEL

z

9 TO 28 VDC POWERED

DESCRIPTION

The CUB4 Volt and Current Meters are designed and manufactured using the

latest technology for a high quality, compact, affordable instrument for use in
industrial environments. Each unit has a 3½-digit LCD display with 0.6 inch
(15.2 mm) high digits and a DIP switch selectable decimal point. The displays
are available in positive image reflective (black digits, reflective background) or
negative image transmissive (illuminated digits, dark background) with red or
yellow/green backlighting.

The units are constructed of a lightweight, high impact plastic case with a

clear viewing window. The sealed front panel meets NEMA 4X/IP65
specifications for wash-down and/or dusty environments, when properly
installed. A CUB4V or CUB4I unit can be mounted in the same panel cutout as
the CUBVD and CUBID units.

The optional Micro Line/Sensor Power Supply (MLPS1000) is designed to

attach to the rear of an installed CUB4V or CUB4I to provide the necessary power
for the unit. The optional supply can be powered from a 85-250 VAC source.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

SPECIFICATIONS

1. 

DISPLAY:

3½-digit (-1999 to 1999), 0.6" (15.2 mm) high digits. Minus (-)

sign is displayed when voltage or current is negative.

2. 

DECIMAL POINTS:

DIP switch selectable decimal points allow the display

to be read in tenths, hundredths or thousandths.

3. 

POWER REQUIREMENTS:

Reflective Versions

: 9 to 28 VDC at 4 mA max.

Backlight Versions

: 9 to 28 VDC @ 35 mA typ., 50 mA max. Above 26

VDC, derate operating temperature to 50°C.

4. 

INPUT RANGES:

D.C. VOLTAGE

D.C. CURRENT

(DIP Switch Selectable)

(JMPR. Selectable)

±199.9 mVDC

±199.9 µADC

±1.999 VDC

±1.999 mADC

±19.99 VDC

±19.99 mADC

±199.9 VDC

±199.9 mADC

5. 

ACCURACY:

(@ 23°C, less than 85% RH)

D.C. Voltage

: ±(

0.1% + 1 digit

)

D.C. Current

:

199.9 µA, 1.999 mA, 19.99 mA ranges

: ±(

0.1% + 1 digit

)

199.9 mA range

: ±(

0.15% + 1 digit

)

6. 

OVERRANGE RATINGS, PROTECTION & INDICATION:

9 to 28 VDC power circuit is not isolated from the signal circuit.

Max Input Voltage

:

0 to 199.9 mVDC Range

: 75 VDC

All other voltage Ranges

: 300 VDC

Max Input Current

:

199.9 µA through 19.99 mA

: 10 times max. range current

199.9 mA

: 1 amp

Overrange Indication

: Overrange is indicated by a “1” displayed in the

most significant digit and the blanking of the three least significant digits.

7. 

READING RATE:

2.5 readings per second

8. 

RESPONSE TIME:

1.5 seconds to settle for a step change

9. 

NORMAL MODE REJECTION:

60 dB 50/60 Hz

MODEL CUB4

I

- MINIATURE D.C. CURRENT METER   &

MODEL CUB4V - MINIATURE D.C. VOLTMETER

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip

installation is 2.15" (54.6) H x 3.00" (76.2) W.

UL Recognized Component,
File # E179259

CAUTION: Read complete

instructions prior to installation

and operation of the unit.

CAUTION: Risk of electric shock.

Bulletin No.  CUB4V/I-J
Drawing No.  LP0256
Released  10/06

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Содержание CUB4I

Страница 1: ...the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired SPECIFICATIONS 1 DISPLAY 3 digit 1999 to 1999 0 6 15 2 mm high digits Minus sign is displayed when voltage or current is negative 2 DECIMAL POINTS DIP switch selectable decimal points allow the display to be read in tenths hundredth...

Страница 2: ...ized Component File E179259 UL3101 1 CSAC22 2 No 1010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc Type 4X Enclosure rating Face only UL50 IECEE CB Scheme Test Certificate UL2356A 179259 USA CB Scheme Test Report 98ME60090 000098 Issued by Underwriters Laboratories Inc IEC 1010 1 EN 61010 1 Safety requirements for electrical...

Страница 3: ...uppression Cores for signal and control cables Fair Rite 0443167251 RLC FCOR0000 TDK ZCAT3035 1330A Steward 28B2029 0A0 Line Filters for input power cables Schaffner FN610 1 07 RLC LFIL0000 Schaffner FN670 1 8 07 Corcom 1VR3 Note Reference manufacturer s instructions when installing a line filter 6 Long cable runs are more susceptible to EMI pickup than short cable runs Therefore keep cable runs a...

Страница 4: ...tch position S3 is set to the ON position The Scaling Potentiometer is then adjusted for the desired readout at a known relative humidity CUB4I SIGNAL INPUT The CUB4 Current Meter has four current ranges that are selected by positioning the jumper in the proper location on the male header strip The SCALE DIP switch S1 and the Scaling Potentiometer are used when it is necessary to scale the display...

Страница 5: ...tiometer for the desired reading ORDERING INFORMATION TYPICAL VOLT CURRENT MEASUREMENT APPLICATIONS CURRENT METER APPLICATION Analog Meter Replacement A manufacturer wants to replace several 1 mA DC analog meter movements with easy to read CUB4 Current Meters with backlighting One application involves measuring the flow rate of a liquid to indicate 0 to 250 gallons per minute Since 1 mA of current...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ...d based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warran...

Отзывы: