2

INSTALLATION ENVIRONMENT

The unit should be installed in a location that does not

exceed the maximum operating temperature and provides
good air circulation. Placing the unit near devices that
generate excessive heat should be avoided. The bezel should
be cleaned only with a soft cloth and neutral soap product.
Do NOT use solvents.

Continuous exposure to direct sunlight may accelerate the

aging process of the bezel.

Do not use tools of any kind (screwdrivers, pens, pencils,

etc.) to operate the keypad of the unit.

Installation

The CUB4 Volt and Current meters meet

NEMA 4X/IP65 requirements for indoor use, when properly
installed. The units are intended to be mounted into an enclosed panel. A
sponge rubber gasket, mounting clip, two screws, and nut fasteners are
provided to install and seal the unit in the panel cutout.

The following procedure assures proper installation:

1.Cut panel opening to specified dimensions. Remove burrs and clean panel

opening.

2. Carefully remove center section of the panel gasket and discard. Slide

gasket over rear of the unit to the back of the bezel.

3. Slide nut fastener into slot on mounting clip and then insert mounting screw

through nut on both sides of mounting clip. Tip of mounting screw should

NOT

project through hole on clip.

4. Install CUB4 unit through panel cutout.
5. Slide mounting clip over rear of unit until clip is against back of panel. The

mounting clip and CUB4 housing have a latching feature to hold the unit in
place until tightened.

Note: Hold the CUB4 front bezel in place when sliding the mounting clip into

position.

6. Alternately tighten each mounting screw to ensure uniform gasket pressure.

Visually inspect the gasket for proper seal. The gasket should be
compressed approximately 75 to 80% of its original thickness.
(Recommended torque is 28 to 36 in-oz.)

7. If the gasket is not adequately compressed and the mounting screws cannot

be tightened any further, loosen mounting screws and insure that the clip is
latched as close as possible to the panel.

8. Repeat step #6 for tightening the mounting screws.

10. 

INPUT IMPEDANCE:

Voltmeter

: 1 M

Current Meter

:

199.9 µA - 1 K

1.999 mA - 100 

19.99 mA - 10 

199.9 mA - 1 

11.

CERTIFICATIONS AND COMPLIANCES:

SAFETY

UL Recognized Component, File # E179259, UL3101-1, CSA C22.2 No. 1010-1

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc. 

Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Certificate # UL2356A-179259/USA, 

CB Scheme Test Report # 98ME60090-000098

Issued by Underwriters Laboratories, Inc.

IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Notes:

1. Self-recoverable loss of performance during EMI disturbance at 10 V/m.

Process signal may deviate during EMI disturbance.

For operation without loss of performance:

Unit is mounted in a metal enclosure (Buckeye SM7013-0 or equivalent)
I/O and power cables are routed in metal conduit connected to earth
ground.

2. Self-recoverable loss of performance during EMI disturbance at 10 Vrms.

Process signal may deviate during EMI disturbance.

For operation without loss of performance:

Install power line filter RLC#LFIL0000 or equivalent at the unit.

Refer to the EMC Installation Guidelines section of this bulletin for

additional information.

12. 

ENVIRONMENTAL CONDITIONS:

Operating Temperature

: 0° to 60°C 

(above 50

°

C, derate backlight

operating voltage to 26 VDC maximum)

.

Storage Temperature

: -40° to 80°C

Operating and Storage Humidity

: 85% max relative humidity (non-

condensing) from 0 to 60°C.

Vibration According to IEC 68-2-6:

5 to 500 Hz, in X, Y, Z direction for

1.5 hours, 5g’s.

Shock According to IEC 68-2-27:

Operational 30 g, 11 msec in 3 directions.

Temperature Coefficient

: 100 PPM/°C

Altitude

: Up to 2000 meters.

13. 

CONSTRUCTION:

High impact plastic case with clear viewing window.

(Panel gasket and mounting clip included.) This unit is rated for NEMA
4X/IP65 indoor use. Installation Category II, Pollution Degree 2

14. 

WEIGHT:

3.3 oz. (93.5 g)

Power mains class A

Enclosure class A

EN 55011

RF interference

Emissions to EN 50081-2

Level 4; 30 A/m

150 KHz - 80 MHz

EN 61000-4-8

Level 3; 10 V/rms 

2

EN 61000-4-6

RF conducted interference

Level 3; 2 Kv power

Level 4; 2 Kv I/O 

EN 61000-4-4

Fast transients (burst)

80 MHz - 1 GHz

Level 3; 10 V/m 

1

EN 61000-4-3

Electromagnetic RF fields

Level 3; 8 Kv air

Level 2; 4 Kv contact

EN 61000-4-2

Electrostatic discharge

200 Hz, 50% duty cycle

900 MHz 

±

5 MHz

Immunity to EN 50082-2

Level 3; 10 V/m

ENV 50204

Simulation of cordless telephone

Power frequency magnetic fields

Содержание CUB4I

Страница 1: ...the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired SPECIFICATIONS 1 DISPLAY 3 digit 1999 to 1999 0 6 15 2 mm high digits Minus sign is displayed when voltage or current is negative 2 DECIMAL POINTS DIP switch selectable decimal points allow the display to be read in tenths hundredth...

Страница 2: ...ized Component File E179259 UL3101 1 CSAC22 2 No 1010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc Type 4X Enclosure rating Face only UL50 IECEE CB Scheme Test Certificate UL2356A 179259 USA CB Scheme Test Report 98ME60090 000098 Issued by Underwriters Laboratories Inc IEC 1010 1 EN 61010 1 Safety requirements for electrical...

Страница 3: ...uppression Cores for signal and control cables Fair Rite 0443167251 RLC FCOR0000 TDK ZCAT3035 1330A Steward 28B2029 0A0 Line Filters for input power cables Schaffner FN610 1 07 RLC LFIL0000 Schaffner FN670 1 8 07 Corcom 1VR3 Note Reference manufacturer s instructions when installing a line filter 6 Long cable runs are more susceptible to EMI pickup than short cable runs Therefore keep cable runs a...

Страница 4: ...tch position S3 is set to the ON position The Scaling Potentiometer is then adjusted for the desired readout at a known relative humidity CUB4I SIGNAL INPUT The CUB4 Current Meter has four current ranges that are selected by positioning the jumper in the proper location on the male header strip The SCALE DIP switch S1 and the Scaling Potentiometer are used when it is necessary to scale the display...

Страница 5: ...tiometer for the desired reading ORDERING INFORMATION TYPICAL VOLT CURRENT MEASUREMENT APPLICATIONS CURRENT METER APPLICATION Analog Meter Replacement A manufacturer wants to replace several 1 mA DC analog meter movements with easy to read CUB4 Current Meters with backlighting One application involves measuring the flow rate of a liquid to indicate 0 to 250 gallons per minute Since 1 mA of current...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ...d based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warran...

Отзывы: