background image

1

  THREE SELECTABLE D.C. RANGES 

 

0 to 10 V, 0(4) to 20 mA, 0 to 50 mA 

  MINIMUM AND MAXIMUM DISPLAY CAPTURE

  LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING

  0.48" (12.2 mm) HIGH DIGITS

  OPTIONAL SETPOINT OUTPUT CARD

  OPTIONAL SERIAL COMMUNICATION CARD (RS232 or RS485)

  OPTIONAL USB PROGRAMMING CARD

  OPERATES FROM 9 TO 28 VDC POWER SOURCE

  FRONT PANEL OR CRIMSON PROGRAMMABLE

  DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT

  NEMA 4X/IP65 SEALED FRONT BEZEL

MODEL CUB

®

5P - MINIATURE ELECTRONIC 5-DIGIT PROCESS METER

GENERAL DESCRIPTION

The CUB5 Series provides the user the ultimate in flexibility, from its 

complete user programming to the optional setpoint control and communication 

capability. The CUB5 accepts a DC voltage or current input signal and provides 

a display in the desired unit of measure. The meter also features minimum and 

maximum display capture, display offset, units indicator, and programmable 

user input. The display can be toggled either manually or automatically between 

the selected displays.

The CUB5 display has 0.48" (12.2 mm) high digits. The LCD is available in 

two versions, reflective or red/green backlight. The backlight version is user 

selectable for the desired color and also has variable display intensity.

The capability of the CUB5 can be easily expanded with the addition of  

option cards. The setpoint output cards are field installable with programmable 

setpoints. Serial communications capability for RS232 or RS485 can be added 

with a serial option card.

The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor 

Power Supply (MLPS), which attaches directly to the back of a CUB5. The 

MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the 

unit and sensors. 

INPUT

The CUB5P is a DC Process meter. It features voltage and current input 

ranges, that are selected by the user via a programming jumper and software 

input range selection. The ranges consist of the following: 0 to 10 V, 0(4) to 20 

mA, or 0 to 50 mA. Users should select the appropriate voltage range that 

covers their maximum input.

SAFETY SUMMARY

All safety related regulations, local codes as well as instructions that appear 

in this document or on equipment must be observed to ensure personal safety 

and to prevent damage to either the device or equipment connected to it. 

Do not use these products to replace proper safety interlocking. No software-

based device (or any other solid-state device) should ever be designed to be 

responsible for the maintenance of personnel safety or consequential equipment 

not equipped with safeguards. Red Lion disclaims any responsibility for 

damages, either direct or consequential, that result from the use of this 

equipment in a manner not consistent with these specifications.

Bulletin No.  CUB5P-J
Drawing No.  LP0655
Released  06/22

CAUTION: Risk of Danger.

Read complete instructions prior to 

installationand operation of the unit.

CAUTION: 

Risk of electric shock.

DIMENSIONS  In inches [mm]

0.13 [3.3]

[43.4]

1.71

2.95 [74.9]

SEL

0.15 [3.8]

1.54 [39.1]

RST

1.29 [32.8]

2.62 [66.6]

1.29

[32.8]

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

C

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

E137808

Содержание CUB 5P

Страница 1: ...n be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS which attaches directly to the back of a CUB5 The MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors INPUT The CUB5P is a DC Process meter It features voltage and current input ranges that are selected by the user via a programming jumper and software input range selection The ranges ...

Страница 2: ...FICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 1 General Requirements EN 61010 2 030 Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component File E179259 UL Listed File E137808 Type 4X Indoor Outdoor ...

Страница 3: ...85 SERIAL COMMUNICATIONS CARD Type RS485 multi point balanced interface non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity Bus Address 0 to 99 max 32 devices per line Transmit Delay Selectable refer to CUB5COM bulletin RS232 SERIAL COMMUNICATIONS CARD Type RS232 half duplex non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity USB PROGRAMMING CA...

Страница 4: ...2010 1 07 Red Lion Controls LFIL0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contacts or both The most effective location is across the load a Using a snubber which is a resistor capacitor RC network or metal oxide varistor MOV across an AC inductive l...

Страница 5: ...N U S A MLPS1 2 WIRE TRANSMITTER COMM INP _ MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V DC COMMON M3424B TERMINAL AC INPUT RED LION CONTROLS YORK PA MADE IN U S A MLPS1 2 WIRE TRANSMITTER INP COMM EXTERNAL POWER COMM COMM VDC VDC _ COMM INP MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V...

Страница 6: ... pressing the SEL button with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module 1 and proceed through each module in sequence When programming is complete it is recommended to record the par...

Страница 7: ...ut Values have to be derived from the actual input signal source or simulator the Apply APLY scaling style must be used KEy APLY 0 000 INP 1 INPUT VALUE FOR SCALING POINT 1 For Key in KEY style enter the known first Input Value using the front panel buttons The Input Range selection sets the decimal location for the Input Value For Apply APLY style the meter shows the previously stored Input Value...

Страница 8: ...ow FACTORY SERVICE OPERATIONS yES NO YES NO Enables the Maximum Display Capture capability Enables the Minimum Display Capture capability The CUB5P uses stored calibration values to provide accurate voltage and current measurements Over time the electrical characteristics of the components inside the meter could slowly change therefore the stored calibration values may no longer accurately define ...

Страница 9: ...Backlight Unit Only 3 dSP dSP t SEL rSt ZErO UNItS COLOr CodE Display Intensity Level d LEV ScroL Display Scroll Enable PARAMETER MENU The yES selection allows the SEL button to toggle through the enabled displays FRONT PANEL DISPLAY SELECT ENABLE SEL This selection allows the RST button to reset the selected value s FRONT PANEL RESET ENABLE RST The yES selection allows the display to automaticall...

Страница 10: ...nced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is used For alarm applications usually unbalanced hysteresis is used For unbalanced hysteresis modes the hysteresis functions on the low side for high acting setpoints and functions on the high side for low acting setpoints Note Hysteresis eliminates output chatter at the switch point while time d...

Страница 11: ...active when one of the optional serial communications programming cards is installed in the meter Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements PARAMETER MENU button or user input manual reset serial reset command or meter power cycle When the u...

Страница 12: ...n tOF n rSt n rEn n ChC n Standby Operation Stb n Front Panel Reset Enable Front Panel Display Select Enable Display Update Time dSP t SEL rSt 3 dSP Display Intensity Level COLOr Units Indicator Selection UNItS Display Color d LEV Programming Security Code CodE rANGE dECPt 1 INP FILtr bANd USrIN INP 1 dSP 1 INP 2 U ASN LO En Min Display Enable Max Capture Delay Time Max Display Enable HI En HI t 2...

Отзывы: