7
TESTING FOR LEAKS
4. TESTING WITH SMOKE
Push smoke test button to begin a 5-minute vapor cycle
VAPOR INDICATOR:
Red Light: Vapor is Generating
Flashing Red Light: See Troubleshooting (Pg 11)
No Light: No Vapor Generating
Turn Flow Control Knob counter-clockwise to release smoke / pressure
Flow Meter indicates flow and measures leak size
Use provided Halogen Inspection Light to locate leaks
Perform repair(s) as needed
5. TESTING WITH AIR-ONLY
Push Air-Only test button to begin a 5-minute vapor cycle
AIR-ONLY INDICATOR:
Blue Light: Machine has adequate power
Turn Flow Control Knob counter-clockwise to release pressure
Flow Meter indicates flow and measures leak
VERIFY REPAIRS
3. CONNECT TO POWER
This machine runs on a fully-charged 12-Volt battery
Connect red lead (+) to battery’s positive terminal
Connect black lead (-) to chassis ground
Do not connect to battery charger
POWER INDICATOR:
Green Light: Machine has adequate power
Flashing Green Light: Improper Power, Power is too high or too low
No Light: No Power, See Troubleshooting (Pg 11)
6. PERFORM DECAY / LEAK DOWN TEST
Pressurize the sealed system
Lock out system by turning Flow Control Knob clockwise to the fully closed position
OBSERVE PRESSURE GAUGE FOR DECAY:
Pressure Holds: No leaks, Repair is complete
Pressure Decreases:
Leak(s) exist, Repair Steps above until all repairs are complete
NOTE: Not all systems are designed to be 100% sealed