1. Compound Pressure Gauge
Indicates amount of pressure or vacuum
Allows for Decay / Leak Down test to
confirm repair is 100% complete
2. Flow Meter
Measures leak size as small as 0.010”
3. Flow Control Knob
Releases vapor / pressure into system by
opening the flow control valve
Close flow control valve to lock out
system for pressure decay testing
4. Power Indicator Light
Green light indicates adequate power
5. Smoke Test Button
Begins 5-minute vapor cycle
Red light indicates vapor cycle
Push again to stop testing
6. Air-Only Test Button
Begins 5-minute air-only cycle to test
without vapor
Blue light indicates onboard micro
compressor is generating air-only
7. Reset Button
Clears stored logic
8. Fluid Fill Port
Use Hex Key to remove Fluid Fill Plug
9. Battery Power Cables
Connects to 12-Volt DC b)
and chassis ground(-)
10. Vapor Output Hose
REFERENCE GUIDE
2
1
2
3
4
5 6 7
8
FRONT VIEW
10
9