![Redline NANOLEAK FINDER AIR BRAKE Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/redline/nanoleak-finder-air-brake/nanoleak-finder-air-brake_operation-manual_1429342004.webp)
2
REFERENCE GUIDE
FRONT VIEW
1
2
4
3
5
6
9
7
8
11
12
13
14
15
16
17
10
BACK VIEW
1. RESET/STOP switch
Clear stored logic / end test / return to home screen
2. PRESSURE SELECT switch
Depress to select desired test pressure
3. VEHICLE SELECT switch
Depress to select desired vehicle configuration
to perform leak down test
4. PASS LEAK TEST indicator
Illuminates when vehicle passes leak down test
5. FAIL LEAK TEST indicator
Illuminates when vehicle fails leak down test
6. CONTRAST (-) switch
Depress to decrease display contrast
7. CONTRAST (+) switch
Depress to increase display contrast
8. LCD screen
9. TEST SYSTEM switch
Depress to begin leak down test
10. SYSTEM BLEED switch
Depress to bleed down system pressure
Caution:
Brakes may engage
11. FIND LEAKS switch
Depress to begin procedure to find leaks
12. Output Hose
13. DC Circuit Breaker
14. Compressed Air Inlet
Replace coupler fitting as necessary.
Female 1/4 inch NPT fitting
15. NanoLeak Solution Fill Port
Remove fluid fill plug to fill machine with Redline
NanoLeak Solution
16. 12/24V DC Power Cable Inlet Port
Depress to begin find leak procedure
17. SYSTEM BLEED Outlet Port
!