Table 30: CLI - set
PTP PMP Parameter/Description
encmode <0 - 4>
Enable or disable the encryption function.
0
- Disable
1
- 64-bit (Redline)
2
- AES 128
3 - AES 192
4 - AES 256
Important
: If encryption is enabled, the same encryption level
must be selected on both communicating systems.
ethmode <auto | 10hd | 10fd | 100 fd | 100hd>
Enter a value for the combined Ethernet speed and duplex.
auto
- Auto-negotiate
10hd
- 10Base-T Half Duplex
10fd
- 10Base-T Full Duplex
100hd
- 100Base-T Half Duplex
100fd
- 100Base-T Full Duplex
exit
Exit from the current mode (go up one level).
flowctrl <on | off>
Enable or disable the flow control function. The Flow control
feature enables the AN-80i to request other Ethernet devices to
pause transmission during busy periods.
off
- Disable
on
- Enable
gateway <IP address>
Enter the IP address of the default gateway on this segment.
gmt <value>
Enter the time offset from GMT (e.g., -5 for EST).
http <on | off>
Enable or disable the HTTP function. When disabled, the Web
interface will not be available.
off
- Disable
on
- Enable
https <on | off>
Enable or disable the HTTPS function.
off
- Disable
on
- Enable
ipaddr <address> <mask>
Enter the IP address and subnet mask of the AN-80i.
Confirmation is required.
Address
- IP Address
Mask
- Subnet Mask
Yes
- Confirmation to proceed
lkname <value>
Enter the name of the remote unit (maximum 15 characters).
maxtxpower <value>
Enter the Tx power level (dBm). This setting is for the
transceiver output only. The actual EIRP depends on the gain
of the connected antenna. See section 8: Appendices for a list