User
AN-80i
Manual
70-00072-01-08b
Proprietary Redline Communications © 2009
Page 12 of 128
June 4, 2009
4.
Provide direct grounding from the unit, the mounting bracket, the antenna, and the
Ethernet cable surge protection to the same ground bus on the building. Use the
grounding screws provided for terminating the ground wires.
1.5
Deployment in the USA and Canada
1.5.1 FCC & IC Notices
1.
The Model AN-80i and its antenna must be professionally installed.
2.
WARNING -- FCC & IC RF Exposure Warnings
To satisfy FCC and IC RF exposure requirements for RF transmitting devices, the
following distances should be maintained between the antenna of this device and
persons during device operation:
Table 1
:
FCC & IC RF Recommended Safe Separation Distances
Frequency (GHz)
Mode
Separation Distance
3.3 - 3.8
PTP / PMP
130 cm (52 in) or more
4.9 - 5.3
PTP / PMP
255 cm (101 in) or more
5.4
PTP / PMP
40 cm (16 in) or more
5.8
PMP
20 cm (8 in) or more
PTP
310 cm (122 in) or more
To ensure compliance, operation at closer than these distances is not
recommended. The antenna used for this transmitter must not be collocated in
conjunction with any other antenna or transmitter.
3.
High power radars are allocated as primary users (meaning they have priority) of
5.250-5.350 MHz and 5.650-5.850 GHz and these radars could cause interference
and/or damage to LE-LAN devices.
4.
FCC Information to Users @ FCC 15.21 & 15.105:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
5.
Where DFS is required by regional regulations, this function is permanently enabled
at the factory and can not be disabled by the installer or end-user. Refer to section
8.5: Regional Codes on page 123 for additional information.
6.
Warning:
Changes or modifications not expressly approved by Redline
Communications could void the user’s authority to operate the equipment.
7.
Refer to section 7.6 for additional information.
1.5.2 Installation and Operation
USA
FCC Part 90 guidelines for deployment of AN-80i systems in the frequency band of
3.650-3.700 GHz for “restricted” CBP (Contention Based Protocol) in USA includes
restrictions on the maximum EIRP.
To comply with the above guidelines, the following EIRP limitations are applied for