Solar PV Tiles – Installation Instructions
18 July 2012
Page 13 of 13
5 REPLACING A PV LAMINATE
If a Redland Solar PV tile becomes damaged due to vandalism or for
any other reason it will need to be replaced. It is possible to replace
individual PV tile laminates for Natural Slate, Richmond 10, Saxon 10,
Landmark Slate 10, MockBond Richmond 10, Mini Stonewold /
Mockbond Mini Stonewold, Landmark Double Pantile / Grovebury,
Landmark Double Roman / 50 Double Roman, Plain Tiles (inc
Rosemary Clay) and DuoPlain without stripping off the installed PV
tile array as follows.
i.
First remove the damaged laminate by unscrewing the small brackets at the leading
edge of the damaged PV tile and sliding the laminate out of the frame.
ii.
Cut the pre-wired connector of the PV tile above the damaged PV tile so that the plug
connection is removed.
iii.
Wire a new plug to the pre-wired cable of the PV tile above.
iv.
Insert new PV laminate into frame securing with screwed brackets at leading edge.
v.
Connect new PV laminate pre-wired connector to new plug of PV tile above.