Solar PV Tiles – Installation Instructions
18 July 2012
Page 12 of 13
iii.
Once the inverter cable has been secured as in step
(ii) then it can be connected to the pre-wired
connectors of the PV tile array as shown.
iv.
The + and – connections from each end of the string
of PV tiles are connected to the + and – inputs of the
inverter as per the circuit diagram.
v.
Additional strings of PV tiles connected in electrical
series can be connected to the inverter using the
other sets of + and – inputs available on the box. Note
the maximum number of PV tiles that can be
connected to the inverter is only limited by the
capacity of the inverter. Check that the inverter has
sufficient capacity for the size of the PV tile array
being connected. For large projects more than one
inverter may be required.