19
12.0 EMPTYING THE WASTE RECEPTACLE
1
2
5
4
3
Figure 13
The waste receptacle should be emptied when the receptacle is full.
The procedure is as follows
(see Figure 13)
:
1. Drive the Verti-Top to the waste-collection dump.
Make sure that the tractor is blocked well and cannot move on its
own accord!
Switch off the tractor before descending!
2. Open the latches (1) on both sides of the Verti-Top.
3. Open the inspection hatch (2) and block the hatch in the blocking strip (5).
Make sure that the inspection hatch is blocked well and cannot fall
shut on its own accord!
4. Remove the pins (3) together with the safety clips from the side panels of the
machine.
5. Tip over the waste receptacle carefully and let it rest against the bottom stop.
6. Remove the excess waste from the waste receptacle (4).
7. Turn the waste receptacle (4) upwards.
8. Mount the pins (3) and the safety clips.
9. Take the inspection hatch (2) out of the blocking strip.
10. Close the inspection hatch (2) carefully.
BE CAREFUL not to get any parts of your body jammed!
11. Secure the inspection hatch (2) with the latches (1) on both sides of the machine.
Remove waste according to the applicable stipulations of the local
legislation.